6130-01-279-4745

POWER SUPPLY


6130-01-279-4745 (6130012794745, 012794745)
Part Numbers (3 listings): LSAD-100 | 01-P32430A001 | 01-P23430A001 |
Summary

FSG 61 / FSC 6130

DEMIL: B

DEMIL INT: 3

HMIC: N

Date Created: 19 May 1988

MSDS: None

Hazmat: None

Export License Required:
Critical Munitions List Item or Sensitive Commerce Control List Item

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 6130-01-279-4745 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
LSAD-1003 - Design Control Reference2 - Production ItemGENERAL DYNAMICS C4 SYSTEMS, INC.  1VPW8    CAGE 1VPW8  
01-P32430A0013 - Design Control Reference2 - Production ItemGENERAL DYNAMICS C4 SYSTEMS, INC.  1VPW8    CAGE 1VPW8  
LSAD-1005 - Replaced / Discontinued9 - No Longer UsedMOTOROLA INC.  94990    CAGE 94990  
01-P32430A0015 - Replaced / Discontinued9 - No Longer UsedMOTOROLA INC.  94990    CAGE 94990  
01-P23430A0015 - Replaced / Discontinued9 - No Longer UsedMOTOROLA INC.  94990    CAGE 94990  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

5 - Replaced / Discontinued

Reference Number Category Code (DRN_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

9 - No Longer Used

Reference Number Variation Code (DRN_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.


FLIS - SEG A - IDENTIFICATION | NSN 6130-01-279-4745 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
616130012794745A3990000740X1BNA019 May 1988
Code Definitions

61

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electric Wire, and Power and Distribution Equipment

6130

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Converters, Electrical, Nonrotating

012794745

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 6130-01-279-4745

A39900

Federal Item Identification Guide (FIIG_4065)

00740

Item Naming Code (INC_4080)

19 May 1988

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

1

Type of Item Identification (TYP_II_4820)


Full Descriptive Item Identification

B

Demilitarization Code (DEMIL_CD_0167)


MLI (Non-Significant Military Equipment – Non-SME) — Demilitarization not required — Trade Security Controls (TSCs) required at disposition.

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

A

Precious Metals Indicator Code (PMIC_0802)


Item does not contain Precious Metal.

0

ADPE Identification Code (ADPEC_0801)


Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)


FLIS - SEG B - MOE RULE DATA | NSN 6130-01-279-4745 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
ZC
ZN
ZX
ZZ
ZN011 Apr 1991
ZX011 Jan 1995
ZC011 Aug 1998
Code Definitions

FLIS - SEG C - REFERENCE NUMBER | NSN 6130-01-279-4745 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
325ZZ01-P32430A001  1VPW8   CAGE/1VPW8
325ZZLSAD-100  1VPW8   CAGE/1VPW8
Code Definitions

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

5

Document Availability Code (DAC_2640)


The reference number is represented by a drawing, but the drawing was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.

ZZ

Reference Number Action Activity Code (RNAAC_2900)


USA


FLIS - SEG G - FREIGHT DATA | NSN 6130-01-279-4745 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
TA658Z9AHZM062900X35110RECTIFIERS-NOI-BATTERY-ELIMINATORS
Code Definitions

TA

Originating Activity Code (ORIG_ACTY_CD_4210)


Sacramento Air Logistics Center, McClellan AFB, CA 95652-5609

658

Water Commodity Code (WRT_CMDTY_CD_9275)


Electical Appliances, Small

Z

Type Cargo Code (TYPE_CGO_CD_9260)


No special type of cargo code applicable

9

Special Handling Code (SP_HDLG_CD_9240)


No special handling required

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

H

Air Commodity Code (AIR_CMTY_HDLG_9215)


Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.

Z

Air Special Handling Code (AIR_CMTY_HDLG_9215)


No special handling required.

M

Less Than Truckload (CLAS_RTNG_CD_2770)


85

062900

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

X

NMFC Sub Item Number (SUB_ITM_NBR_0861)

35110

Uniform Freight Classification (UFC_CD_MODF_3040)

RECTIFIERS-NOI-BATTERY-ELIMINATORS

Freight Description (FRT_DESC_4020)

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 6130-01-279-4745 Submit RFQ
MRCDecoded RequirementClear Text Reply
AKWCElectrical Power Source RelationshipOPERATING
AGAVEnd Item IdentificationLST-5B
CBBLFeatures ProvidedOVER VOLTAGE PROTECTOR AND FUSE AND INPUT TO OUTPUT ISOLATION AND INPUT TO CASE ISOLATION AND OUTPUT TO CASE ISOLATION AND INPUT FILTER AND OUTPUT FILTER AND OVER TEMPERATURE PROTECTION
AYNHOperating Ambient Temp Range-30.0/+55.0 DEG CELSIUS
CWHFOutput Connection Quantity1 SINGLE POWER OUTPUT
CWHJOutput Connection TypeCONNECTOR, RECEPTACLE SINGLE POWER OUTPUT
CWGHOutput Current Rating3.6 DC AMPERES NOMINAL SINGLE POWER OUTPUT
APPAOutput Voltage Rating27.0 DC VOLTS NOMINAL SINGLE POWER OUTPUT
CWHTInput Connection Quantity1 SINGLE OPERATING POWER RQMT
CWHQInput Connection TypeCONNECTOR, PLUG SINGLE OPERATING POWER RQMT
ANPMInput PhaseSINGLE SINGLE OPERATING POWER RQMT
APTQInput Frequency Rating47.0 HERTZ MINIMUM SINGLE OPERATING POWER RQMT AND 400.0 HERTZ MAXIMUM SINGLE OPERATING POWER RQMT
APNXInput Voltage Rating216.0 AC VOLTS MINIMUM 1ST ALTERNATE OPERATING POWER RQMT AND 264.0 AC VOLTS MAXIMUM 1ST ALTERNATE OPERATING POWER RQMT
APNXInput Voltage Rating108.0 AC VOLTS MINIMUM 2ND ALTERNATE OPERATING POWER RQMT AND 132.0 AC VOLTS MAXIMUM 2ND ALTERNATE OPERATING POWER RQMT
APNXInput Voltage Rating11.0 DC VOLTS MINIMUM 3RD ALTERNATE OPERATING POWER RQMT AND 30.0 DC VOLTS MAXIMUM 3RD ALTERNATE OPERATING POWER RQMT
ABKWOverall Height3.000 INCHES NOMINAL
ABHPOverall Length6.745 INCHES NOMINAL
ABMKOverall Width5.500 INCHES NOMINAL


Back to Top