Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
6622A | 3 - Design Control Reference | 2 - Production Item | AGILENT TECHNOLOGIES, INC. | 1LQK8 | ![]() |
6622A | 5 - Replaced / Discontinued | 9 - No Longer Used | HEWLETT PACKARD CO | 28480 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
61 | 6130 | 012850004 | A39900 | 00740 | N | K | A | N | A | 0 | 3 Sep 1988 |
Electric Wire, and Power and Distribution Equipment
The item does not have a critical feature such as tolerance, fit restrictions or application. Nuclear hardness properties have not been determined (not valid for input).
Full Descriptive - Reference Item Identification
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.
Item does not contain Precious Metal.
Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
G860 | 0 | 0 | C | 1 Apr 1991 | ||||||||||||||||||||||||||
ZA01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
YJ01 | 1 Apr 1994 | |||||||||||||||||||||||||||||
YB01 | 1 Dec 1998 | |||||||||||||||||||||||||||||
YA01 | 1 Jul 2001 | |||||||||||||||||||||||||||||
ZB01 | 1 Jul 2005 | |||||||||||||||||||||||||||||
ZR01 | 1 Dec 2007 | |||||||||||||||||||||||||||||
ZH01 | 1 Apr 2008 | |||||||||||||||||||||||||||||
WZ01 | 1 Aug 2011 |
Not Established
SERVICE/AGENCY-MANAGED (Service/Agency use only.) Issue, transfer, or shipment is not subject to specialized controls other than those imposed by individual Services supply policy. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with Service requisitioning procedures.
RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
3 | 2 | 2 | ZZ | 6622A | 1LQK8 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
The reference number is represented by a drawing and the drawing was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the drawing.
USA
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
5 | 97 | 0 | 3 Sep 1988 |
An item authorized for procurement that has not yet been subject to item standardization.
DLIS-LFF, Battle Creek, MI 49037-3084
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
TA | 658 | Z | 9 | A | H | Z | M | 062900 | X | 35110 | RECTIFIERS-NOI-BATTERY-ELIMINATORS |
Sacramento Air Logistics Center, McClellan AFB, CA 95652-5609
Electical Appliances, Small
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
No special handling required.
85
No Variation. NMFC and UFCC Match.
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
AKWC | Electrical Power Source Relationship | OPERATING |
CBBL | Features Provided | GROUND WIRE TERMINAL AND INPUT TO OUTPUT ISOLATION AND INPUT TO CASE ISOLATION AND OUTPUT TO CASE ISOLATION AND OVER VOLTAGE PROTECTOR AND OVER CURRENT PROTECTOR |
CWHF | Output Connection Quantity | 4 SINGLE POWER OUTPUT |
CWHJ | Output Connection Type | TERMINAL STRIP SINGLE POWER OUTPUT |
CWGH | Output Current Rating | 0.0 DC AMPERES MINIMUM 1ST POWER OUTPUT AND 2.0 DC AMPERES MAXIMUM 1ST POWER OUTPUT |
CWGH | Output Current Rating | 0.0 DC AMPERES MINIMUM 2ND POWER OUTPUT AND 4.0 DC AMPERES MAXIMUM 2ND POWER OUTPUT |
APPA | Output Voltage Rating | 0.0 DC VOLTS MINIMUM 1ST POWER OUTPUT AND 50.0 DC VOLTS MAXIMUM 1ST POWER OUTPUT |
APPA | Output Voltage Rating | 0.0 DC VOLTS MINIMUM 2ND POWER OUTPUT AND 20.0 DC VOLTS MAXIMUM 2ND POWER OUTPUT |
ANPM | Input Phase | SINGLE SINGLE OPERATING POWER RQMT |
APTQ | Input Frequency Rating | 47.0 HERTZ MINIMUM SINGLE OPERATING POWER RQMT AND 66.0 HERTZ MAXIMUM SINGLE OPERATING POWER RQMT |
APNX | Input Voltage Rating | 120.0 AC VOLTS NOMINAL SINGLE OPERATING POWER RQMT |
ABKW | Overall Height | 5.220 INCHES NOMINAL |
ABHP | Overall Length | 19.600 INCHES NOMINAL |
ABMK | Overall Width | 16.750 INCHES NOMINAL |
CWKG | Ventilation Design Type | SINGLE FAN |