Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
S-30967-95 | 3 - Design Control Reference | 9 - No Longer Used | SARGENT-WELCH SCIENTIFIC CO | 64484 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
61 | 6130 | 012892966 | A39900 | 00740 | X | K | A | N | A | 0 | 20 Nov 1988 |
Electric Wire, and Power and Distribution Equipment
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Full Descriptive - Reference Item Identification
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.
Item does not contain Precious Metal.
Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
FGG4 | FAA4 | 0 | 0 | X | D | 99 | 1 Sep 2000 |
Not Established
All other conditions.
Major End Items of Equipment: Items of such importance to the operations readiness of operating units that they are subject to continuing centralized individual item management and asset control throughout all command and support echelons.
Depot source of repair has not been assigned. This is a temporary code that will be used only until a DSOR is assigned as specified in joint Service regulation AMC-R 750û10, OPNAVINST 4790.14A AFI 21û133(I), MCO P4790.10B, DLAD 4151.16, Joint Depot Maintenance Program, 31 March 1999.
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
5 | 97 | 0 | 20 Nov 1988 |
An item authorized for procurement that has not yet been subject to item standardization.
DLIS-LFF, Battle Creek, MI 49037-3084
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
TA | M | 738 | 3 | 9 | A | H | Z | M | 062900 | X | 35110 | RECTIFIERS-NOI-BATTERY-ELIMINATORS |
Sacramento Air Logistics Center, McClellan AFB, CA 95652-5609
85
Computing Equipment, Computer Components, and Circuit Cards
Electrostatic Sensitive Device (ESD), subject to damage caused by electrostatic discharge. (See DoD 4500.32-R, Volume 1, Appendix A, Section I for additional information on ESD devices).
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
No special handling required.
No Variation. NMFC and UFCC Match.
Warner Robins Air Logistics Center, 455 Byron St, Robins AFB, GA 31098-1860
TERMINAL ITEM (NON-STOCKED ITEMS) Future procurement is not authorized. No wholesale stock is available for issue. 1. Requisitions will not be processed to the wholesale manager. 2. Internal Service/agency requisitioning may be continued in accordance with the Service/agency requisitioning policies.
Unclassified
1
AIR FORCE ERRC NF2: AF Equipment Management System (AFEMS); NAVY: Fast moving centrally managed 1I COG forms (locally procured at selected designated overseas activities)
Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.
TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.
Department of the Air Force
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
AKWC | Electrical Power Source Relationship | OPERATING |
CBBL | Features Provided | ON-OFF SWITCH-INDICATOR AND DC AMMETER AND MODE SELECTION SWITCH AND DC VOLTMETER AND FUSE |
CWHF | Output Connection Quantity | 5 SINGLE POWER OUTPUT |
CWHJ | Output Connection Type | BINDING POST SINGLE POWER OUTPUT |
CWGH | Output Current Rating | 0.0 DC AMPERES MINIMUM 1ST POWER OUTPUT AND 10.0 DC AMPERES MAXIMUM 1ST POWER OUTPUT |
CWGH | Output Current Rating | 0.0 DC AMPERES MINIMUM 2ND POWER OUTPUT AND 20.0 DC AMPERES MAXIMUM 2ND POWER OUTPUT |
APPA | Output Voltage Rating | 6.0 DC VOLTS NOMINAL 2ND POWER OUTPUT |
APPA | Output Voltage Rating | 12.0 DC VOLTS NOMINAL 1ST POWER OUTPUT |
CWHT | Input Connection Quantity | 1 SINGLE OPERATING POWER RQMT |
CWHQ | Input Connection Type | WIRE LEAD SINGLE OPERATING POWER RQMT |
APTQ | Input Frequency Rating | 50.0 HERTZ MINIMUM SINGLE OPERATING POWER RQMT AND 60.0 HERTZ MAXIMUM SINGLE OPERATING POWER RQMT |
ANPM | Input Phase | SINGLE SINGLE OPERATING POWER RQMT |
APNX | Input Voltage Rating | 115.0 AC VOLTS NOMINAL SINGLE OPERATING POWER RQMT |
ABKW | Overall Height | 178.0 MILLIMETERS NOMINAL |
ABHP | Overall Length | 216.0 MILLIMETERS NOMINAL |
ABMK | Overall Width | 305.0 MILLIMETERS NOMINAL |
CWKG | Ventilation Design Type | CONVECTION |