Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
L-DSW28-1-715 | 3 - Design Control Reference | 9 - No Longer Used | VEECO INSTRUMENTS INC | 80103 | ![]() |
LDS-W-28 | 5 - Replaced / Discontinued | 9 - No Longer Used | VEECO INSTRUMENTS INC | 80103 | ![]() |
L-DSW5-1-715E | D - Drawing Number Reference | 9 - No Longer Used | VEECO INSTRUMENTS INC | 80103 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.
Drawing Number Reference. A number assigned by a design activity to a drawing or other technical documentation which identifies a drawing/document that is related to an item of supply or production but does not qualify for assignment of codes 1,3,5,7, or C. Code D reference numbers will not be used in item-of-supply determinations.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
61 | 6130 | 013016244 | A39900 | 00740 | X | 1 | A | N | A | 0 | 1 Jun 1989 |
Electric Wire, and Power and Distribution Equipment
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Full Descriptive Item Identification
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.
Item does not contain Precious Metal.
Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ZA01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZC01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZW01 | 1 Dec 2005 | |||||||||||||||||||||||||||||
YS01 | 1 Feb 2015 |
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
5 | 97 | 0 | 1 Jun 1989 |
An item authorized for procurement that has not yet been subject to item standardization.
DLIS-LFF, Battle Creek, MI 49037-3084
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
TA |
Sacramento Air Logistics Center, McClellan AFB, CA 95652-5609
No Variation. NMFC and UFCC Match.
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
AKWC | Electrical Power Source Relationship | OPERATING |
AGAV | End Item Identification | PAECE SHIELD A |
ADZC | Environmental Protection | FUNGUS PROOF |
CBBL | Features Provided | REMOTE ERROR SENSING CAPABILITY AND OVER VOLTAGE PROTECTOR AND OVER TEMPERATURE PROTECTION |
AYNH | Operating Ambient Temp Range | -0.1/+60.0 DEG CELSIUS |
CWHF | Output Connection Quantity | 2 SINGLE POWER OUTPUT |
CWHJ | Output Connection Type | TERMINAL STRIP SINGLE POWER OUTPUT |
CWGH | Output Current Rating | 2.6 DC AMPERES MINIMUM SINGLE POWER OUTPUT AND 4.0 DC AMPERES MAXIMUM SINGLE POWER OUTPUT |
APPA | Output Voltage Rating | 26.6 DC VOLTS MINIMUM SINGLE POWER OUTPUT AND 29.4 DC VOLTS MAXIMUM SINGLE POWER OUTPUT |
CWHT | Input Connection Quantity | 3 SINGLE OPERATING POWER RQMT |
CWHQ | Input Connection Type | TERMINAL STRIP SINGLE OPERATING POWER RQMT |
ANPM | Input Phase | SINGLE SINGLE OPERATING POWER RQMT |
APTQ | Input Frequency Rating | 47.0 HERTZ MINIMUM SINGLE OPERATING POWER RQMT AND 440.0 HERTZ MAXIMUM SINGLE OPERATING POWER RQMT |
APNX | Input Voltage Rating | 210.0 AC POUNDS PER HOUR DRY 1ST ALTERNATE OPERATING POWER RQMT AND 254.0 AC POUNDS PER HOUR WITH RETAINING CHAIN 1ST ALTERNATE OPERATING POWER RQMT |
APNX | Input Voltage Rating | 105.0 AC POUNDS PER HOUR DRY 2ND ALTERNATE OPERATING POWER RQMT AND 127.0 AC POUNDS PER HOUR WITH RETAINING CHAIN 2ND ALTERNATE OPERATING POWER RQMT |
ABKW | Overall Height | 2.843 INCHES NOMINAL |
ABHP | Overall Length | 9.000 INCHES NOMINAL |
ABMK | Overall Width | 4.875 INCHES NOMINAL |
CWKG | Ventilation Design Type | CONVECTION |