Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
G452138-4 | 3 - Design Control Reference | 2 - Production Item | RAYTHEON TECHNICAL SERVICES COMPANY | 3B150 | ![]() |
G452138-4 | 5 - Replaced / Discontinued | 9 - No Longer Used | RAYTHEON COMPANY | 49956 | ![]() |
G452138 | D - Drawing Number Reference | 9 - No Longer Used | RAYTHEON COMPANY | 49956 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.
Drawing Number Reference. A number assigned by a design activity to a drawing or other technical documentation which identifies a drawing/document that is related to an item of supply or production but does not qualify for assignment of codes 1,3,5,7, or C. Code D reference numbers will not be used in item-of-supply determinations.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
61 | 6130 | 013297418 | A39900 | 00295 | X | 1 | B | N | A | 0 | 21 Nov 1990 |
Electric Wire, and Power and Distribution Equipment
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Full Descriptive Item Identification
MLI (Non-Significant Military Equipment – Non-SME) — Demilitarization not required — Trade Security Controls (TSCs) required at disposition.
Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.
Item does not contain Precious Metal.
Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
FUU4 | FAA4 | 0 | 0 | F | E | FH | 1 Nov 1999 |
Not Established
An activity within the Air Force is providing depot maintenance support.
Reparables: Centrally managed recoverable items designated as reparable for the reasons that repair of unserviceable quantities of the items are considered by the inventory manager in satisfying requirements prior to or in conjunction with determining procurement quantities.
Ogden Air Logistics Center (OO-ALC), Hill AFB, UT
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
5 | 97 | 0 | 21 Nov 1990 |
An item authorized for procurement that has not yet been subject to item standardization.
DLIS-LFF, Battle Creek, MI 49037-3084
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
TA | 658 | Z | 9 | A | H | Z | M | 062900 | X | 35110 | RECTIFIERS-NOI-BATTERY-ELIMINATORS |
Sacramento Air Logistics Center, McClellan AFB, CA 95652-5609
Electical Appliances, Small
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
No special handling required.
85
No Variation. NMFC and UFCC Match.
Ogden Air Logistics Center, 5851 F Ave, Hill AFB, UT 84056-5713
TERMINAL ITEM (NON-STOCKED ITEMS) Future procurement is not authorized. No wholesale stock is available for issue. 1. Requisitions will not be processed to the wholesale manager. 2. Internal Service/agency requisitioning may be continued in accordance with the Service/agency requisitioning policies.
Unclassified
1
AIR FORCE ERRC XD2: AF Recoverable Assembly Management System (AFRAMS); NAVY: Terminal Items
Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.
TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.
Department of the Air Force
Source | PICA / SICA | Packaging Category | Storage | Preservation | Clean/Dry | INT Qty | Unit Weight | Unit Size | Unit Pack Cube | Item Weight | Item Dims |
---|---|---|---|---|---|---|---|---|---|---|---|
P | P | GX | 1 | 000 | 75.6 lbs | 31in x 28in x 15in | 7.534 cu ft | 55.0 lbs | 23.5in x 19in x 5.5in |
Preservation Material | Wrapping Material | Cushioning / Dunnage | Cushioning Thickness | Unit Container | Intermediate Container | Unit Container Level | Special Marking | Level A Packing | Level B Packing | Minimal Packing | Optional Procedure |
---|---|---|---|---|---|---|---|---|---|---|---|
00 | X | NV | 00 | B | 39 | F | M |
Primary Inventory Control Activity (PICA)
Primary Inventory Control Activity (PICA)
Preserve by Method 41 as follows: Items subject to damage by electromagnetic and electrostatic field forces shall be initially wrapped in material conforming to MIL-PRF-81705, Type III, or bags conforming to MIL-DTL-117, Type II, Class H, Style 2, or cushioned in material conforming to A-A-3129, Type I, Grade B or PPP-C-795, Class 2 or PPP-C-1797, Type II, to prevent bag puncture, and unit packed in a heat-sealed bag conforming to MIL-DTL-117, Type I, Class F, Style 1. Reclosable cushioned pouches conforming to MIL-DTL-81997, Type I or II, may be used in lieu of initial wrap or cushioning. Lead or terminal configurations for all items shall be maintained as manufactured without causing loads or stresses capable of causing damage to the item. Materials used to maintain item position and lead or terminal configuration shall permit item removal without damage to the item. Electrostatic discharge (ESD) sensitive caution labels shall be applied in accordance with MIL-STD-129.
Any suitable process that is not injurious to the item.
No requirement
As required to protect the item or elements of the package
PPP-B-1672, Type III, telescoping encapsulated cushioning in reusable box.
No requirement.
Unit container provides level B packing protection.
ESD sensitive electronic device requirements of MIL-STD-129 apply
Packing is not required: the unit container shall also serve as the shipping container. Closure, sealing and reinforcement shall be in accordance with applicable specification for shipping container.
All packaging data is mandatory for compliance and no substitutions are permitted. Fast packs should be included in this category.
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
AKWC | Electrical Power Source Relationship | OPERATING |
AGAV | End Item Identification | AN/FPS/120; NEXT ASSEMBLY G245070-1 OR G452071-1; USED ON BMEWS |
CBBL | Features Provided | ON-OFF SWITCH-INDICATOR AND OVER VOLTAGE PROTECTOR AND VOLTAGE ADJUSTMENT |
AKAE | Maximum Operating Altitude Rating | 10000.0 FEET |
AYNH | Operating Ambient Temp Range | -0.0/+40.0 DEG CELSIUS |
CWHF | Output Connection Quantity | 5 SINGLE POWER OUTPUT |
CWHJ | Output Connection Type | CONNECTOR, RECEPTACLE SINGLE POWER OUTPUT |
CWGH | Output Current Rating | 4.1 DC AMPERES NOMINAL 4TH POWER OUTPUT |
CWGH | Output Current Rating | 4.1 DC AMPERES NOMINAL 3RD POWER OUTPUT |
CWGH | Output Current Rating | 4.7 DC AMPERES NOMINAL 1ST POWER OUTPUT |
CWGH | Output Current Rating | 4.7 DC AMPERES NOMINAL 2ND POWER OUTPUT |
APPA | Output Voltage Rating | 0.0 DC VOLTS MINIMUM AND 6.0 DC VOLTS MAXIMUM 4TH POWER OUTPUT |
APPA | Output Voltage Rating | 14.25 DC VOLTS MINIMUM AND 15.2 AC VOLTS MAXIMUM 1ST POWER OUTPUT |
APPA | Output Voltage Rating | 14.25 DC VOLTS MINIMUM AND 15.2 DC VOLTS MAXIMUM 2ND POWER OUTPUT |
APPA | Output Voltage Rating | 4.75 DC VOLTS MINIMUM AND 5.25 DC VOLTS MAXIMUM 3RD POWER OUTPUT |
CWHT | Input Connection Quantity | 1 SINGLE OPERATING POWER RQMT |
CWHQ | Input Connection Type | CONNECTOR, PLUG SINGLE OPERATING POWER RQMT |
APTQ | Input Frequency Rating | 60.0 HERTZ NOMINAL SINGLE OPERATING POWER RQMT |
ANPM | Input Phase | SINGLE SINGLE OPERATING POWER RQMT |
APNX | Input Voltage Rating | 115.0 AC POUNDS PER HOUR WET SINGLE OPERATING POWER RQMT |
AMQY | Installation Design | RACK |
BGQF | Power Unit Quantity | 6 |
AMKG | Power Unit Type | SILICON CONTROLLED RECTIFIER SINGLE OPERATING POWER RQMT |
CWGZ | Ripple Voltage At Full Load | 150.0 MICROVOLTS AVERAGE MULTIPLE POWER OUTPUTS W/IDENTICAL RATINGS |
ABKW | Overall Height | 5.250 INCHES NOMINAL |
ABHP | Overall Length | 23.500 INCHES NOMINAL |
ABMK | Overall Width | 19.000 INCHES NOMINAL |
FEAT | Special Features | ALTERED ITEM FROM CAGE 49956 P/N G452144-1; VENDOR ITEM LAMBDA CAGE 80103 ASSEMBLY NUMBER 23573; CONSISTING OF POWER SUPPLY P/N LDS-X-15 QTY 2;P/NLDS-X-01 QTY 2; P/N L-12-OV-15 QTY 2; P/N LRA-17 QTY 1; P/N LM-OV-1 QTY 2; ADDED UNDERVOLTAGE DETECTION CIRCUITRYWHICH CREATES A MARGINED OUTPUT |
CWKG | Ventilation Design Type | AIR COOLED |