| Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
|---|---|---|---|---|---|
| RJC212-OVP-TH-E-TBC | 3 - Design Control Reference | 2 - Production Item | TDK-LAMBDA AMERICAS INC. | 89022 | |
| 10140460-101 | 7 - Vendor Item Drawing Reference | 2 - Production Item | HONEYWELL INTERNATIONAL INC. | 94580 | |
| 10140460 | D - Drawing Number Reference | 9 - No Longer Used | HONEYWELL INTERNATIONAL INC. | 94580 | |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
Vendor Item Drawing Reference (formerly Specification Control Reference). The number assigned by a design activity to a drawing that is not item-identifying, but which delineates existing commercial or vendor-developed items meeting all engineering and test requirements specified, without imposing additional test/engineering requirements not normally provided by the vendor(s). Includes only those drawings which meet the definition for Vendor Item Drawing in MIL-STD 100. Vendor Item Drawing References are administrative control numbers and shall not be used as part identification numbers.
Drawing Number Reference. A number assigned by a design activity to a drawing or other technical documentation which identifies a drawing/document that is related to an item of supply or production but does not qualify for assignment of codes 1,3,5,7, or C. Code D reference numbers will not be used in item-of-supply determinations.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
| FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 61 | 6130 | 013613814 | A39900 | 00740 | X | K | A | N | A | 0 | 16 Jul 1992 |
Electric Wire, and Power and Distribution Equipment
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Full Descriptive - Reference Item Identification
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.
Item does not contain Precious Metal.
Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
| MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| FGG4 | FEE4 | 0 | 0 | F | E | FR | 1 Sep 2000 | |||||||||||||||||||||||
Not Established
An activity within the Air Force is providing depot maintenance support.
Reparables: Centrally managed recoverable items designated as reparable for the reasons that repair of unserviceable quantities of the items are considered by the inventory manager in satisfying requirements prior to or in conjunction with determining procurement quantities.
Warner-Robins Air Logistics Center (WR-ALC), Robins AFB, GA
| ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
|---|---|---|---|---|---|---|---|---|
| 5 | 97 | 0 | 16 Jul 1992 |
An item authorized for procurement that has not yet been subject to item standardization.
DLIS-LFF, Battle Creek, MI 49037-3084
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
| Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| SE | M | 738 | 3 | 9 | A | H | Z | M | 062900 | X | 35110 | RECTIFIERS-NOI-BATTERY-ELIMINATORS |
San Antonio Air Logistics Center, Kelly AFB, TX 78241-5000
85
Computing Equipment, Computer Components, and Circuit Cards
Electrostatic Sensitive Device (ESD), subject to damage caused by electrostatic discharge. (See DoD 4500.32-R, Volume 1, Appendix A, Section I for additional information on ESD devices).
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
No special handling required.
No Variation. NMFC and UFCC Match.
Warner Robins Air Logistics Center, 455 Byron St, Robins AFB, GA 31098-1860
SERVICE/AGENCY-MANAGED (Service/Agency use only.) Issue, transfer, or shipment is not subject to specialized controls other than those imposed by individual Services supply policy. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with Service requisitioning procedures.
Unclassified
1
AIR FORCE ERRC XD2: AF Recoverable Assembly Management System (AFRAMS); NAVY: Terminal Items
Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.
TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.
Department of the Air Force
| Source | PICA / SICA | Packaging Category | Storage | Preservation | Clean/Dry | INT Qty | Unit Weight | Unit Size | Unit Pack Cube | Item Weight | Item Dims |
|---|---|---|---|---|---|---|---|---|---|---|---|
| P | P | GX | 1 | 000 | 9.0 lbs | 12.5in x 12.5in x 14.5in | 1.311 cu ft | 4.0 lbs | 7in x 4in x 3.5in |
| Preservation Material | Wrapping Material | Cushioning / Dunnage | Cushioning Thickness | Unit Container | Intermediate Container | Unit Container Level | Special Marking | Level A Packing | Level B Packing | Minimal Packing | Optional Procedure |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 00 | X | NR | 00 | B | 39 | M |
Primary Inventory Control Activity (PICA)
Primary Inventory Control Activity (PICA)
Preserve by Method 41 as follows: Items subject to damage by electromagnetic and electrostatic field forces shall be initially wrapped in material conforming to MIL-PRF-81705, Type III, or bags conforming to MIL-DTL-117, Type II, Class H, Style 2, or cushioned in material conforming to A-A-3129, Type I, Grade B or PPP-C-795, Class 2 or PPP-C-1797, Type II, to prevent bag puncture, and unit packed in a heat-sealed bag conforming to MIL-DTL-117, Type I, Class F, Style 1. Reclosable cushioned pouches conforming to MIL-DTL-81997, Type I or II, may be used in lieu of initial wrap or cushioning. Lead or terminal configurations for all items shall be maintained as manufactured without causing loads or stresses capable of causing damage to the item. Materials used to maintain item position and lead or terminal configuration shall permit item removal without damage to the item. Electrostatic discharge (ESD) sensitive caution labels shall be applied in accordance with MIL-STD-129.
Any suitable process that is not injurious to the item.
No requirement
As required to protect the item or elements of the package
PPP-B-1672, Type I, vertical star cushioning in reusable box.
No requirement.
Unit container provides level B packing protection.
ESD sensitive electronic device requirements of MIL-STD-129 apply
All packaging data is mandatory for compliance and no substitutions are permitted. Fast packs should be included in this category.
| MRC | Decoded Requirement | Clear Text Reply |
|---|---|---|
| AKWC | Electrical Power Source Relationship | OPERATING |
| AGAV | End Item Identification | 4920-01-342-4734 |
| CBBL | Features Provided | OVER TEMPERATURE PROTECTION AND OVER VOLTAGE PROTECTOR AND OVER CURRENT PROTECTOR |
| AKAE | Maximum Operating Altitude Rating | 6000.0 FEET |
| AYNH | Operating Ambient Temp Range | +0.1/+71.0 DEG CELSIUS |
| CWHF | Output Connection Quantity | 2 SINGLE POWER OUTPUT |
| CWHJ | Output Connection Type | TERMINAL STRIP SINGLE POWER OUTPUT |
| CWHC | Output Control Location | FRONT PANEL SINGLE POWER OUTPUT |
| CWGH | Output Current Rating | 3.0 DC AMPERES NOMINAL SINGLE POWER OUTPUT |
| APPA | Output Voltage Rating | 15.0 DC VOLTS MAXIMUM SINGLE POWER OUTPUT AND -15.0 DC VOLTS MINIMUM SINGLE POWER OUTPUT |
| CWHQ | Input Connection Type | TERMINAL STRIP SINGLE OPERATING POWER RQMT |
| ANPM | Input Phase | SINGLE SINGLE OPERATING POWER RQMT |
| CWHM | Input Current Rating | 2.0 AC AMPERES NOMINAL SINGLE OPERATING POWER RQMT |
| APTQ | Input Frequency Rating | 47.0 HERTZ MINIMUM SINGLE OPERATING POWER RQMT AND 400.0 HERTZ MAXIMUM SINGLE OPERATING POWER RQMT |
| APNX | Input Voltage Rating | 115.0 AC POUNDS PER HOUR WET SINGLE OPERATING POWER RQMT |
| ABKW | Overall Height | 4.900 INCHES NOMINAL |
| ABHP | Overall Length | 9.380 INCHES NOMINAL |
| ABMK | Overall Width | 3.230 INCHES NOMINAL |
| FEAT | Special Features | FUNGUS INERT CONFORMAL COATING,TERMINAL BLOCK COVER,POWER SUPPLY PROVIDES FOR EITHER POSITIVE OR NEGATIVE OUTPUTS |
| CWKG | Ventilation Design Type | CONVECTION |