| Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
|---|---|---|---|---|---|
| 500-2 | 3 - Design Control Reference | 2 - Production Item | AMETEK PROGRAMMABLE POWER, INC. | 25965 | |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
| FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 61 | 6130 | 013630912 | A39900 | 00740 | X | 1 | B | N | A | 0 | 21 Aug 1992 |
Electric Wire, and Power and Distribution Equipment
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Full Descriptive Item Identification
MLI (Non-Significant Military Equipment – Non-SME) — Demilitarization not required — Trade Security Controls (TSCs) required at disposition.
Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.
Item does not contain Precious Metal.
Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
| MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| YB01 | 1 Oct 1996 | |||||||||||||||||||||||||||||
| YA01 | 1 Jul 2001 | |||||||||||||||||||||||||||||
| F5KE | FGG4 | 0 | 0 | 4 | E | CN | 1 Jun 2013 | |||||||||||||||||||||||
| N2R4 | NAGS | 0 | 0 | P | E | CN | GG | 1 Jun 2013 | ||||||||||||||||||||||
Not Established
Depot Reparable Component. (Type I Temporary). This code identifies SICA managed depot reparable components assigned to another service PICA that is responsible for the logistics functions of single submitter of cataloging data, acquisition and disposal authority and depot maintenance to be provided by DMISA. Supply support requirements will be submitted by the SICA to the PICA on MIPRs unless otherwise directed by the PICA. The SICA is responsible for the wholesale stock, store and issue functions for SICA activities. This code is temporarily assigned to items which have not completed Phase II item review processing. The SICA CMD will reflect Source of Supply or SOS Modifiers compatible with the SICA managing activity. The PICA will not be entered in the DAAS IMM field.
Reparables: Centrally managed recoverable items designated as reparable for the reasons that repair of unserviceable quantities of the items are considered by the inventory manager in satisfying requirements prior to or in conjunction with determining procurement quantities.
Total depot maintenance is being accomplished by commercial contract.
Contract, Contiguous United States (CONUS)
Naval Inventory Control Point, Philadelphia, PA 19111û5098
| ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
|---|---|---|---|---|---|---|---|---|
| 5 | 97 | 0 | 21 Aug 1992 |
An item authorized for procurement that has not yet been subject to item standardization.
DLIS-LFF, Battle Creek, MI 49037-3084
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
| Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| SE | M | 593 | Z | 9 | A | H | Z | M | 062900 | X | 35110 | RECTIFIERS-NOI-BATTERY-ELIMINATORS |
San Antonio Air Logistics Center, Kelly AFB, TX 78241-5000
85
Motors and Parts, (machinery and parts), (less than 35 feet)
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
No special handling required.
No Variation. NMFC and UFCC Match.
NAVICP-ERP, 700 Robbins Avenue, Philadelphia, PA 19111-5098
RESTRICTED REQUISITIONS-MAJOR OVERHAUL (Service/Agency use only.) Items (Assemblies and/or component parts) which for lack of specialized tools, test equipment, etc., can be used only by major overhaul activities. Base, post, camp or station activities will not requisition unless authorized to perform major overhaul function.
Unclassified
1
NAVY: Special Program Reparables
Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.
TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.
Department of the Navy
| MRC | Decoded Requirement | Clear Text Reply |
|---|---|---|
| AKWC | Electrical Power Source Relationship | OPERATING |
| AGAV | End Item Identification | F110 ACFT/GE100 ENG |
| CBBL | Features Provided | PROGRAMMABLE AND OVER TEMPERATURE PROTECTION AND OVER VOLTAGE PROTECTOR |
| AYNH | Operating Ambient Temp Range | +0.1/+50.0 DEG CELSIUS |
| CWHF | Output Connection Quantity | 1 2ND POWER OUTPUT |
| CWHF | Output Connection Quantity | 1 3RD POWER OUTPUT |
| CWHF | Output Connection Quantity | 1 1ST POWER OUTPUT |
| CWHJ | Output Connection Type | TERMINAL STRIP 1ST POWER OUTPUT |
| CWHJ | Output Connection Type | TERMINAL STRIP 2ND POWER OUTPUT |
| CWHJ | Output Connection Type | TERMINAL STRIP 3RD POWER OUTPUT |
| CWHC | Output Control Location | REAR PANEL 1ST POWER OUTPUT |
| CWHC | Output Control Location | REAR PANEL 2ND POWER OUTPUT |
| CWHC | Output Control Location | REAR PANEL 3RD POWER OUTPUT |
| CWGH | Output Current Rating | 0.0 AC AMPERES MINIMUM 1ST POWER OUTPUT AND 9.2 AC AMPERES MAXIMUM 1ST POWER OUTPUT |
| CWGH | Output Current Rating | 0.0 AC AMPERES MINIMUM 2ND POWER OUTPUT AND 2.25 AC AMPERES MAXIMUM 2ND POWER OUTPUT |
| CWGH | Output Current Rating | 0.0 AC AMPERES MINIMUM 3RD POWER OUTPUT AND 1.1 AC AMPERES MAXIMUM 3RD POWER OUTPUT |
| CWGN | Output Phase | TWO 1ST POWER OUTPUT |
| CWGN | Output Phase | TWO 2ND POWER OUTPUT |
| CWGN | Output Phase | TWO 3RD POWER OUTPUT |
| APPA | Output Voltage Rating | 0.0 AC VOLTS MINIMUM 1ST POWER OUTPUT AND 32.0 AC VOLTS MAXIMUM 1ST POWER OUTPUT |
| APPA | Output Voltage Rating | 0.0 AC VOLTS MINIMUM 3RD POWER OUTPUT AND 260.0 AC VOLTS MAXIMUM 3RD POWER OUTPUT |
| APPA | Output Voltage Rating | 0.0 AC VOLTS MINIMUM 2ND POWER OUTPUT AND 130.0 AC VOLTS MAXIMUM 2ND POWER OUTPUT |
| APTS | Output Frequency Rating | 45.0 HERTZ MINIMUM 2ND POWER OUTPUT AND 5.0 KILOHERTZ MAXIMUM 2ND POWER OUTPUT |
| APTS | Output Frequency Rating | 45.0 HERTZ MINIMUM 3RD POWER OUTPUT AND 5.0 KILOHERTZ MAXIMUM 3RD POWER OUTPUT |
| APTS | Output Frequency Rating | 45.0 HERTZ MINIMUM 1ST POWER OUTPUT AND 5.0 KILOHERTZ MAXIMUM 1ST POWER OUTPUT |
| CWHT | Input Connection Quantity | 1 1ST ALTERNATE OPERATING POWER RQMT |
| CWHT | Input Connection Quantity | 1 2ND ALTERNATE OPERATING POWER RQMT |
| CWHQ | Input Connection Type | TERMINAL STRIP 1ST ALTERNATE OPERATING POWER RQMT |
| CWHQ | Input Connection Type | TERMINAL STRIP 2ND ALTERNATE OPERATING POWER RQMT |
| ANPM | Input Phase | SINGLE 1ST ALTERNATE OPERATING POWER RQMT |
| ANPM | Input Phase | SINGLE 2ND ALTERNATE OPERATING POWER RQMT |
| CWHM | Input Current Rating | 1500.0 AC AMPERES NOMINAL 1ST ALTERNATE OPERATING POWER RQMT |
| CWHM | Input Current Rating | 1500.0 AC AMPERES NOMINAL 2ND ALTERNATE OPERATING POWER RQMT |
| APTQ | Input Frequency Rating | 47.0 HERTZ MINIMUM 1ST ALTERNATE OPERATING POWER RQMT AND 63.0 HERTZ MAXIMUM 1ST ALTERNATE OPERATING POWER RQMT |
| APTQ | Input Frequency Rating | 47.0 HERTZ MINIMUM 2ND ALTERNATE OPERATING POWER RQMT AND 63.0 HERTZ MAXIMUM 2ND ALTERNATE OPERATING POWER RQMT |
| APNX | Input Voltage Rating | 230.0 AC POUNDS PER HOUR WET 2ND ALTERNATE OPERATING POWER RQMT |
| APNX | Input Voltage Rating | 115.0 AC POUNDS PER HOUR WET 1ST ALTERNATE OPERATING POWER RQMT |
| ABKW | Overall Height | 5.250 INCHES NOMINAL |
| ABHP | Overall Length | 19.000 INCHES NOMINAL |
| ABMK | Overall Width | 16.000 INCHES NOMINAL |
| FEAT | Special Features | CONSIST OF:2 EA MODEL 251B;1 EA 400SR AND 1 EA 990-302-92 CABLE PLUS ASELECTED OSCILLATOR |