6130-01-386-7111

POWER SUPPLY


6130-01-386-7111 (6130013867111, 013867111)
Part Numbers (2 listings): EJK2335-046 | 706-1433-000 |
Summary

FSG 61 / FSC 6130

DEMIL: A

DEMIL INT:

HMIC: N

Date Created: 11 Feb 1994

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 6130-01-386-7111 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
EJK2335-0463 - Design Control Reference9 - No Longer UsedUNIPOWER, LLC  0RWG8      
706-1433-0005 - Replaced / Discontinued9 - No Longer UsedUNIPOWER, LLC  0RWG8      
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

5 - Replaced / Discontinued

Reference Number Category Code (DRN_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

9 - No Longer Used

Reference Number Variation Code (DRN_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.


FLIS - SEG A - IDENTIFICATION | NSN 6130-01-386-7111 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
616130013867111A3990000740XKANA011 Feb 1994
Code Definitions

61

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electric Wire, and Power and Distribution Equipment

6130

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Converters, Electrical, Nonrotating

013867111

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 6130-01-386-7111

A39900

Federal Item Identification Guide (FIIG_4065)

00740

Item Naming Code (INC_4080)

11 Feb 1994

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

K

Type of Item Identification (TYP_II_4820)


Full Descriptive - Reference Item Identification

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

A

Precious Metals Indicator Code (PMIC_0802)


Item does not contain Precious Metal.

0

ADPE Identification Code (ADPEC_0801)


Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)


FLIS - SEG B - MOE RULE DATA | NSN 6130-01-386-7111 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
ZC011 Jun 1994
ZX011 Mar 2004
ZU011 May 2008
YS011 Feb 2015
Code Definitions

FLIS - SEG C - REFERENCE NUMBER | NSN 6130-01-386-7111 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
392ZZEJK2335-046  0RWG8  
592ZZ706-1433-000  0RWG8  
Code Definitions

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

9

Reference Number Variation Code (RNVC_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.

2

Document Availability Code (DAC_2640)


The reference number is represented by a drawing and the drawing was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the drawing.

ZZ

Reference Number Action Activity Code (RNAAC_2900)


USA

5

Reference Number Category Code (RNCC_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 6130-01-386-7111 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
597011 Feb 1994
Code Definitions

5

Item Standardization Code (ISC_2650)


An item authorized for procurement that has not yet been subject to item standardization.

97

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


DLIS-LFF, Battle Creek, MI 49037-3084

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

11 Feb 1994

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 6130-01-386-7111 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
TK658Z9AHZM062900X35110RECTIFIERS-NOI-BATTERY-ELIMINATORS
Code Definitions

TK

Originating Activity Code (ORIG_ACTY_CD_4210)


HQ AFMC/GLSC 401 SCM/GUMB, Wright-Patterson AFB, OH 45433-5000

658

Water Commodity Code (WRT_CMDTY_CD_9275)


Electical Appliances, Small

Z

Type Cargo Code (TYPE_CGO_CD_9260)


No special type of cargo code applicable

9

Special Handling Code (SP_HDLG_CD_9240)


No special handling required

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

H

Air Commodity Code (AIR_CMTY_HDLG_9215)


Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.

Z

Air Special Handling Code (AIR_CMTY_HDLG_9215)


No special handling required.

M

Less Than Truckload (CLAS_RTNG_CD_2770)


85

062900

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

X

NMFC Sub Item Number (SUB_ITM_NBR_0861)

35110

Uniform Freight Classification (UFC_CD_MODF_3040)

RECTIFIERS-NOI-BATTERY-ELIMINATORS

Freight Description (FRT_DESC_4020)

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 6130-01-386-7111 Submit RFQ
MRCDecoded RequirementClear Text Reply
AKWCElectrical Power Source RelationshipOPERATING
AGAVEnd Item IdentificationAN/TPS-72(V)5
CBBLFeatures ProvidedEMI FILTER AND OVER TEMPERATURE PROTECTION AND OVER VOLTAGE PROTECTOR
AYNHOperating Ambient Temp Range+0.1/+71.0 DEG CELSIUS
CWHJOutput Connection TypeCONNECTOR, PLUG 1ST POWER OUTPUT AND TERMINAL STRIP 1ST POWER OUTPUT
CWHJOutput Connection TypeCONNECTOR, PLUG 2ND POWER OUTPUT AND TERMINAL STRIP 2ND POWER OUTPUT
CWHJOutput Connection TypeCONNECTOR, PLUG 3RD POWER OUTPUT AND TERMINAL STRIP 3RD POWER OUTPUT
CWHJOutput Connection TypeCONNECTOR, PLUG 4TH POWER OUTPUT AND TERMINAL STRIP 4TH POWER OUTPUT
CWGHOutput Current Rating3.0 DC AMPERES NOMINAL 1ST POWER OUTPUT
CWGHOutput Current Rating10.0 DC AMPERES NOMINAL 2ND POWER OUTPUT
CWGHOutput Current Rating100.0 DC AMPERES NOMINAL 4TH POWER OUTPUT
CWGHOutput Current Rating12.0 DC AMPERES NOMINAL 3RD POWER OUTPUT
APPAOutput Voltage Rating24.0 DC POUNDS PER HOUR WET 1ST POWER OUTPUT
APPAOutput Voltage Rating5.0 DC POUNDS PER HOUR WET 4TH POWER OUTPUT
APPAOutput Voltage Rating12.0 DC POUNDS PER HOUR WET 3RD POWER OUTPUT
APPAOutput Voltage Rating12.0 DC POUNDS PER HOUR WET 2ND POWER OUTPUT
ANPMInput PhaseSINGLE 1ST ALTERNATE OPERATING POWER RQMT
ANPMInput PhaseSINGLE 2ND ALTERNATE OPERATING POWER RQMT
APTQInput Frequency Rating47.0 HERTZ MINIMUM 1ST ALTERNATE OPERATING POWER RQMT AND 63.0 HERTZ MAXIMUM 1ST ALTERNATE OPERATING POWER RQMT
APTQInput Frequency Rating47.0 HERTZ MINIMUM 2ND ALTERNATE OPERATING POWER RQMT AND 63.0 HERTZ MAXIMUM 2ND ALTERNATE OPERATING POWER RQMT
APNXInput Voltage Rating90.0 AC VOLTS MINIMUM 1ST ALTERNATE OPERATING POWER RQMT AND 132.0 AC VOLTS MAXIMUM 1ST ALTERNATE OPERATING POWER RQMT
APNXInput Voltage Rating180.0 AC VOLTS MINIMUM 2ND ALTERNATE OPERATING POWER RQMT AND 264.0 AC VOLTS MAXIMUM 2ND ALTERNATE OPERATING POWER RQMT
CWWYPower Supply Efficiency Line75.0
ABKWOverall Height5.000 INCHES NOMINAL
ABHPOverall Length13.500 INCHES NOMINAL
ABMKOverall Width8.000 INCHES NOMINAL
FEATSpecial FeaturesMADE FROM CA001-1453, COMPUTER PRODUCTS
CWKGVentilation Design TypeSINGLE FAN


Back to Top
Back to Top