6130-01-397-6735

POWER SUPPLY


6130-01-397-6735 (6130013976735, 013976735)
Part Number (1 listing): 6633AOPT760
Summary

FSG 61 / FSC 6130

DEMIL: B

DEMIL INT: 3

HMIC: N

Date Created: 17 Oct 1994

MSDS: None

Hazmat: None

Export License Required:
Critical Munitions List Item or Sensitive Commerce Control List Item

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 6130-01-397-6735 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
6633AOPT7603 - Design Control Reference9 - No Longer UsedAGILENT TECHNOLOGIES INC.  07980      
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

9 - No Longer Used

Reference Number Variation Code (DRN_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.


FLIS - SEG A - IDENTIFICATION | NSN 6130-01-397-6735 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
616130013976735A3990000740XM3BNA017 Oct 1994
Code Definitions

61

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electric Wire, and Power and Distribution Equipment

6130

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Converters, Electrical, Nonrotating

013976735

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 6130-01-397-6735

A39900

Federal Item Identification Guide (FIIG_4065)

00740

Item Naming Code (INC_4080)

17 Oct 1994

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

M

Type of Item Identification (TYP_II_4820)


Partial Descriptive - Reference Item Identification (Type 1A Concept)

3

Reference / Partial Descriptive Method Reason Code (RPDMRC_4765)


An approved item name and FIIG exist but the item involved is so unique in design that it cannot be fully described in accordance with the FIIG.

B

Demilitarization Code (DEMIL_CD_0167)


MLI (Non-Significant Military Equipment – Non-SME) — Demilitarization not required — Trade Security Controls (TSCs) required at disposition.

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

A

Precious Metals Indicator Code (PMIC_0802)


Item does not contain Precious Metal.

0

ADPE Identification Code (ADPEC_0801)


Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)


FLIS - SEG B - MOE RULE DATA | NSN 6130-01-397-6735 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
ZB011 Dec 2006
Code Definitions

FLIS - SEG C - REFERENCE NUMBER | NSN 6130-01-397-6735 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
392ZZ6633AOPT760  07980  
Code Definitions

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

9

Reference Number Variation Code (RNVC_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.

2

Document Availability Code (DAC_2640)


The reference number is represented by a drawing and the drawing was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the drawing.

ZZ

Reference Number Action Activity Code (RNAAC_2900)


USA


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 6130-01-397-6735 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
597017 Oct 1994
Code Definitions

5

Item Standardization Code (ISC_2650)


An item authorized for procurement that has not yet been subject to item standardization.

97

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


DLIS-LFF, Battle Creek, MI 49037-3084

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

17 Oct 1994

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 6130-01-397-6735 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
TK
Code Definitions

TK

Originating Activity Code (ORIG_ACTY_CD_4210)


HQ AFMC/GLSC 401 SCM/GUMB, Wright-Patterson AFB, OH 45433-5000

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 6130-01-397-6735 Submit RFQ
MRCDecoded RequirementClear Text Reply
AGAVEnd Item IdentificationF-15 DEPOT
CWGHOutput Current Rating0.0 DC AMPERES MINIMUM SINGLE POWER OUTPUT AND 2.0 DC AMPERES MAXIMUM SINGLE POWER OUTPUT
APPAOutput Voltage Rating0.0 DC VOLTS MINIMUM SINGLE POWER OUTPUT AND 50.0 DC VOLTS MAXIMUM SINGLE POWER OUTPUT
FEATSpecial FeaturesZOPT 760ISOLATION AND REVERSAL RELAYS;INCLUDES DISCRETE FAULT INDICATOR AND REMOTE INHIBIT;HP-IB PROGRAMMING OF VOLTAGE AND CURRENT;MEASURED VOLTAGEAND CURRENT READBACK OVER THE HP-IB;PROGRAMMABLE OVERVOLTAGE AND OVERCURRENTPROTECTION


Back to Top