| Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
|---|---|---|---|---|---|
| DCF 203 | 3 - Design Control Reference | 2 - Production Item | INTERNATIONAL POWER SOURCES INC | 0JSW7 | |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
| FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 61 | 6130 | 014141503 | A39900 | 00740 | X | K | A | N | A | 1 Jun 1995 |
Electric Wire, and Power and Distribution Equipment
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Full Descriptive - Reference Item Identification
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.
Item does not contain Precious Metal.
| MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| C056 | 3 | H | 1 Jun 1995 | |||||||||||||||||||||||||||
Acquire directly from the actual manufacturer, whether or not the prime contractor is the actual manufacturer.
The Government physically does not have in its possession sufficient, accurate, or legible data to purchase this part from other than current source(s). (NOTE: This code is applicable only to parts under immediate buy requirements and only as long as the deficiency is under review for resolution and appropriate recoding.) Valid AMCs: 1, 2, 3, 4 and 5.
| RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 3 | 2 | 4 | ZZ | DCF 203 | 0JSW7 | | ||||||
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the technical documentation.
USA
| ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
|---|---|---|---|---|---|---|---|---|
| 5 | 97 | 0 | 1 Jun 1995 |
An item authorized for procurement that has not yet been subject to item standardization.
DLIS-LFF, Battle Creek, MI 49037-3084
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
| Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| XG |
USCG Engineering Logistics Center, Baltimore, MD 21226-5000
No Variation. NMFC and UFCC Match.
Commanding Officer, USCG Surface Force Logistics Center, Code 028, Mil Stop 25, 2401 Hawkins Point Road, Baltimore, MD 21226-5000
TERMINAL ITEM. Identifies items in stock, but future procurement is not authorized. Requisitions may continue to be submitted until stocks are exhausted. Preferred item National Stock Number is normally provided by application of the phrase: When Exhausted Use (NSN). Requisitions will be submitted in accordance with IMM/Service requisitioning procedures as applicable.
Unclassified
1
COAST GUARD: Reparable item. Repair, condemnation, and disposal not authorized below depot (Inventory Control Point (ICP)) level; DLA: This item has been reviewed and a determination has been made that the item can be restored to a serviceable condition from an unserviceable condition at the depot level; NAVY: Resale-Brand Name Perishable Subsistence
Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.
TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.
U.S. Coast Guard
| MRC | Decoded Requirement | Clear Text Reply |
|---|---|---|
| AKWC | Electrical Power Source Relationship | OPERATING |
| AGAV | End Item Identification | ECC CONSOLE |
| CBBL | Features Provided | FUSE AND GROUND WIRE TERMINAL AND GROUNDING AND INPUT FILTER AND INPUT TO CASE ISOLATION AND INPUT TO OUTPUT ISOLATION AND OVER VOLTAGE PROTECTOR AND REMOTE CONTROL AND REMOTE ERROR SENSING CAPABILITY |
| AYNH | Operating Ambient Temp Range | -20.0/+50.0 DEG CELSIUS |
| CWHF | Output Connection Quantity | 5 SINGLE POWER OUTPUT |
| CWHJ | Output Connection Type | TERMINAL STRIP SINGLE POWER OUTPUT |
| CWHC | Output Control Location | REAR PANEL SINGLE POWER OUTPUT |
| BGHX | Output Control Quantity | 1 SINGLE POWER OUTPUT |
| BGHY | Output Control Type | FINE VOLTAGE ADJUSTMENT SINGLE POWER OUTPUT |
| CWGH | Output Current Rating | 11.0 DC AMPERES MAXIMUM SINGLE POWER OUTPUT |
| APPA | Output Voltage Rating | 15.0 DC POUNDS PER HOUR WET SINGLE POWER OUTPUT |
| BGQR | Output Wattage Rating | 150.0 WATTS NOMINAL SINGLE POWER OUTPUT |
| CWHT | Input Connection Quantity | 3 SINGLE OPERATING POWER RQMT |
| CWHQ | Input Connection Type | TERMINAL STRIP SINGLE OPERATING POWER RQMT |
| APNX | Input Voltage Rating | 24.0 DC VOLTS NOMINAL SINGLE OPERATING POWER RQMT |
| CWWZ | Power Supply Efficiency Battery | 85.0 |
| CWGW | Power Supply Output Current/Voltage Characteristics | CONSTANT VOLTAGE SINGLE POWER OUTPUT AND LIMITING CURRENT SINGLE POWER OUTPUT |
| FEAT | Special Features | 19 TO 32 VDC INPUT VOLTAGE RANGE; OUTPUT SHORT CIRCUIT PROTECTION; 50 KHZ SWITCHING FREQUENCY; 10 PERCENT VOLTAGE ADJUSTMENT |
| ABKW | Overall Height | 3.819 INCHES NOMINAL |
| ABHP | Overall Length | 8.543 INCHES NOMINAL |
| ABMK | Overall Width | 2.756 INCHES NOMINAL |
| CXCY | Part Name Assigned By Controlling Agency | DC/DC CONVERTER |