| Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
|---|---|---|---|---|---|
| 5204615-1 | 1 - Source of Control Reference | 2 - Production Item | HONEYWELL INTL INC | 0VWL8 | |
| 24327 | 3 - Design Control Reference | 2 - Production Item | KEPCO, INC. | 85604 | |
Source of Control Reference. The number assigned by a design control manufacturer of an end item of equipment, including a Government activity, to a drawing that restricts procurement (1) to the specified item(s) described on the drawing and (2) to the stated source(s) of supply designated thereon. These restrictions are imposed on the cognizant design activity to ensure procurement of the only item(s) known as a result of test or evaluation to be satisfactory for the stated critical application. Includes only those drawings which meet the definition for Source Control Drawing in MIL-STD-100. (Applicable only to type 1, 1B, 2, 4 and 4B item identifications.)
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
| FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 61 | 6130 | 014573712 | A39900 | 00295 | Y | 1 | A | N | B | A | 0 | 21 Jul 1998 |
Electric Wire, and Power and Distribution Equipment
The item does not have a nuclear hardened feature but does have other critical feature(s) such as tolerance, fit restriction or application.
Full Descriptive Item Identification
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.
Represents items with ESD sensitivity.
Item does not contain Precious Metal.
Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
| MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| FGG4 | 0 | 0 | F | E | FR | 1 Jul 1998 | ||||||||||||||||||||||||
Not Established
An activity within the Air Force is providing depot maintenance support.
Reparables: Centrally managed recoverable items designated as reparable for the reasons that repair of unserviceable quantities of the items are considered by the inventory manager in satisfying requirements prior to or in conjunction with determining procurement quantities.
Warner-Robins Air Logistics Center (WR-ALC), Robins AFB, GA
Source of Control Reference. The number assigned by a design control manufacturer of an end item of equipment, including a Government activity, to a drawing that restricts procurement (1) to the specified item(s) described on the drawing and (2) to the stated source(s) of supply designated thereon. These restrictions are imposed on the cognizant design activity to ensure procurement of the only item(s) known as a result of test or evaluation to be satisfactory for the stated critical application. Includes only those drawings which meet the definition for Source Control Drawing in MIL-STD-100. (Applicable only to type 1, 1B, 2, 4 and 4B item identifications.)
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
The reference number is represented by a drawing and the drawing was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the drawing.
USA
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
| ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
|---|---|---|---|---|---|---|---|---|
| 5 | 97 | 0 | 21 Jul 1998 |
An item authorized for procurement that has not yet been subject to item standardization.
DLIS-LFF, Battle Creek, MI 49037-3084
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
| Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| TG | M | 738 | Z | 9 | A | H | Z | M | 062900 | X | 35110 | RECTIFIERS-NOI-BATTERY-ELIMINATORS |
Warner-Robins Air Logistics Center, Robins AFB, GA 31098-5609
85
Computing Equipment, Computer Components, and Circuit Cards
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
No special handling required.
No Variation. NMFC and UFCC Match.
Warner Robins Air Logistics Center, 455 Byron St, Robins AFB, GA 31098-1860
SERVICE/AGENCY-MANAGED (Service/Agency use only.) Issue, transfer, or shipment is not subject to specialized controls other than those imposed by individual Services supply policy. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with Service requisitioning procedures.
Unclassified
1
AIR FORCE ERRC XD2: AF Recoverable Assembly Management System (AFRAMS); NAVY: Terminal Items
Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.
TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.
Department of the Air Force
| Source | PICA / SICA | Packaging Category | Storage | Preservation | Clean/Dry | INT Qty | Unit Weight | Unit Size | Unit Pack Cube | Item Weight | Item Dims |
|---|---|---|---|---|---|---|---|---|---|---|---|
| P | P | 42 | 1 | 000 | 86.0 lbs | 29.8in x 24.8in x 15.3in | 6.543 cu ft | 66.0 lbs | 23in x 19in x 7.5in |
| Preservation Material | Wrapping Material | Cushioning / Dunnage | Cushioning Thickness | Unit Container | Intermediate Container | Unit Container Level | Special Marking | Level A Packing | Level B Packing | Minimal Packing | Optional Procedure |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 00 | ZZ | ZZ | Z | ZZ | 00 | B | 17 | A |
Primary Inventory Control Activity (PICA)
Primary Inventory Control Activity (PICA)
Container, watervaporproof bag, sealed, container
Any suitable process that is not injurious to the item.
No requirement
Special requirements – see specific instructions or drawings provided
Special requirements. See specific instructions or drawings provided.
Special requirements-See specific instructions or drawings provided
Special requirement – See specific instructions or drawings provided.
No requirement.
Unit container provides level B packing protection.
Reusable container
Packaging is in accordance with a procedural specification or a SPI. The appropriate specification number will be shown in-the-clear in the supplemental data area.
| MRC | Decoded Requirement | Clear Text Reply |
|---|---|---|
| AKWC | Electrical Power Source Relationship | SELF-CONTAINED |
| AGAV | End Item Identification | C141C |
| CRTL | Criticality Code Justification | FEAT |
| AYNH | Operating Ambient Temp Range | -20.0/+45.0 DEG CELSIUS |
| CWHF | Output Connection Quantity | 6 SINGLE POWER OUTPUT |
| CWHJ | Output Connection Type | TAPERED POST SINGLE POWER OUTPUT |
| CWGH | Output Current Rating | 45.0 DC AMPERES MINIMUM MULTIPLE POWER OUTPUTS W/IDENTICAL RATINGS AND 5.7 DC AMPERES MAXIMUM MULTIPLE POWER OUTPUTS W/IDENTICAL RATINGS |
| BGQR | Output Wattage Rating | 200.0 WATTS NOMINAL SINGLE POWER OUTPUT |
| APPA | Output Voltage Rating | 0.0 DC VOLTS MINIMUM AND 15.0 DC VOLTS MAXIMUM 1ST POWER OUTPUT |
| APPA | Output Voltage Rating | 0.0 DC VOLTS MINIMUM AND 15.0 DC VOLTS MAXIMUM 2ND POWER OUTPUT |
| APPA | Output Voltage Rating | 0.0 DC VOLTS MINIMUM AND 15.0 DC VOLTS MAXIMUM 3RD POWER OUTPUT |
| APPA | Output Voltage Rating | 0.0 DC VOLTS MINIMUM AND 36.0 DC VOLTS MAXIMUM 4TH POWER OUTPUT |
| APPA | Output Voltage Rating | 0.0 DC VOLTS MINIMUM AND 36.0 DC VOLTS MAXIMUM 5TH POWER OUTPUT |
| APPA | Output Voltage Rating | 0.0 DC VOLTS MINIMUM AND 36.0 DC VOLTS MAXIMUM 6TH POWER OUTPUT |
| APTQ | Input Frequency Rating | 47.0 HERTZ MINIMUM SINGLE OPERATING POWER RQMT AND 63.0 HERTZ MAXIMUM SINGLE OPERATING POWER RQMT |
| ANPM | Input Phase | SINGLE SINGLE OPERATING POWER RQMT |
| APNX | Input Voltage Rating | 90.0 AC POUNDS PER HOUR DRY SINGLE OPERATING POWER RQMT AND 264.0 AC POUNDS PER HOUR WITH RETAINING CHAIN SINGLE OPERATING POWER RQMT |
| AEAS | Major Components | ASSEMBLY CONSISTS OF ONE RACK ADAPTER, P/N RA-55; ONE POWER SUPPLY CONTROLLER, P/N MST488-27; THREE MST15-12M POWER SUPPLIES; THREE MST36-5M POWER SUPPLIES AND TWO RFP55-1 FILLER PANELS |
| BGQF | Power Unit Quantity | 6 |
| AMKG | Power Unit Type | REGULATED BIAS SINGLE OPERATING POWER RQMT |
| ABKW | Overall Height | 7.000 INCHES NOMINAL |
| ABHP | Overall Length | 22.000 INCHES NOMINAL |
| ABMK | Overall Width | 19.000 INCHES NOMINAL |
| CXCY | Part Name Assigned By Controlling Agency | DC POWER SUPPLY |
| FEAT | Special Features | ELECTROSTATIC SENSITIVE |