6130-01-468-3166

POWER SUPPLY


6130-01-468-3166 (6130014683166, 014683166)
Part Number (1 listing): BK300
Summary

FSG 61 / FSC 6130

DEMIL: A

DEMIL INT: 1

HMIC: N

Date Created: 5 Oct 1999

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 6130-01-468-3166 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
BK3003 - Design Control Reference9 - No Longer UsedSCHNEIDER ELECTRIC IT CORPORATION  0MG77      
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

9 - No Longer Used

Reference Number Variation Code (DRN_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.


FLIS - SEG A - IDENTIFICATION | NSN 6130-01-468-3166 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
616130014683166A3990000740X1ANAA05 Oct 1999
Code Definitions

61

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electric Wire, and Power and Distribution Equipment

6130

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Converters, Electrical, Nonrotating

014683166

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 6130-01-468-3166

A39900

Federal Item Identification Guide (FIIG_4065)

00740

Item Naming Code (INC_4080)

5 Oct 1999

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

1

Type of Item Identification (TYP_II_4820)


Full Descriptive Item Identification

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

A

Electrostatic Discharge Code (ESD_EMI_CD_2043)


No known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity.

A

Precious Metals Indicator Code (PMIC_0802)


Item does not contain Precious Metal.

0

ADPE Identification Code (ADPEC_0801)


Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)


FLIS - SEG B - MOE RULE DATA | NSN 6130-01-468-3166 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
ZC011 Oct 1999
ZX011 Sep 2000
Code Definitions

FLIS - SEG C - REFERENCE NUMBER | NSN 6130-01-468-3166 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
43949ZDBK300  0MG77  
Code Definitions

4

Reference Number Format Code (RNFC_2920)


Number is totally in-the-clear (without modification) as originally configured by the manufacturer, design control activity, or supplier.

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

9

Reference Number Variation Code (RNVC_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.

4

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the technical documentation.

9Z

Reference Number Action Activity Code (RNAAC_2900)


DLIS-K, Battle Creek, MI 49037-3084

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 6130-01-468-3166 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
59705 Oct 1999
Code Definitions

5

Item Standardization Code (ISC_2650)


An item authorized for procurement that has not yet been subject to item standardization.

97

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


DLIS-LFF, Battle Creek, MI 49037-3084

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

5 Oct 1999

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 6130-01-468-3166 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
DF
Code Definitions

DF

Originating Activity Code (ORIG_ACTY_CD_4210)


U.S. Army Tank Automotive Command, Warren, MI 48090

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 6130-01-468-3166 Submit RFQ
MRCDecoded RequirementClear Text Reply
AKWCElectrical Power Source RelationshipOPERATING
CWHYBattery Feature And TypeRECHARGEABLE LEAD ACID CELL
CWJFBattery LocationINTERNAL
AEXRBattery Quantity1
CXMXBattery Power Supply Emergency Operating Time20.7
CWWBBattery Recovery Time360.0
AYNHOperating Ambient Temp Range+32.0/+120.0 DEG FAHRENHEIT
CWHFOutput Connection Quantity2 SINGLE POWER OUTPUT
CWHJOutput Connection TypeRECEPTACLE, ELECTRICAL SINGLE POWER OUTPUT
CWGHOutput Current Rating300.0 AC VOLT-AMPERE NOMINAL SINGLE POWER OUTPUT
APTSOutput Frequency Rating55.0 HERTZ MINIMUM SINGLE POWER OUTPUT AND 65.0 HERTZ MAXIMUM SINGLE POWER OUTPUT
CWGNOutput PhaseSINGLE SINGLE POWER OUTPUT
APPAOutput Voltage Rating120.0 AC VOLTS NOMINAL SINGLE POWER OUTPUT
APTQInput Frequency Rating55.0 HERTZ MINIMUM SINGLE OPERATING POWER RQMT AND 65.0 HERTZ MAXIMUM SINGLE OPERATING POWER RQMT
ANPMInput PhaseSINGLE SINGLE OPERATING POWER RQMT
CWHTInput Connection Quantity1 SINGLE OPERATING POWER RQMT
CWHQInput Connection TypeCONNECTOR, PLUG SINGLE OPERATING POWER RQMT
APNXInput Voltage Rating120.0 AC POUNDS PER HOUR WET SINGLE OPERATING POWER RQMT
ABKWOverall Height6.000 INCHES MAXIMUM
ABHPOverall Length13.100 INCHES MAXIMUM
ABMKOverall Width3.400 INCHES MAXIMUM
CXCYPart Name Assigned By Controlling AgencyBACK-UPS 300 UNINTERRUPTIBLE POWER SUPPLY
FEATSpecial FeaturesSINE WAVEFORM TYPE; 13.1 POUNDS WEIGHT; BEIGE COLOR; 40 DBA NOISE; 10 BTU/HR ONLINE THERMAL DISSIPATION; 4MS TYPICAL TO 8MS MAXIMUM TRANSFER TIME; 320 JOULES SURGE RATING


Back to Top