| Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
|---|---|---|---|---|---|
| MRW161KV | 3 - Design Control Reference | 2 - Production Item | KEPCO, INC. | 85604 | |
| 222-4270-160 | 5 - Replaced / Discontinued | 2 - Production Item | ROCKWELL COLLINS FRANCE | F5491 | |
| 218-0313-010 | 5 - Replaced / Discontinued | 2 - Production Item | ROCKWELL COLLINS FRANCE | F5491 | |
| 218-0313-010 | 5 - Replaced / Discontinued | 2 - Production Item | ROCKWELL COLLINS, INC. | 13499 | |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
| FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 61 | 6130 | 014713471 | A39900 | 00740 | X | 1 | A | N | A | A | 0 | 31 Jan 2000 |
Electric Wire, and Power and Distribution Equipment
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Full Descriptive Item Identification
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.
No known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity.
Item does not contain Precious Metal.
Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
| MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| ZF01 | 1 Jan 2000 | |||||||||||||||||||||||||||||
| RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 4 | 3 | 2 | 4 | 9Z | D | MRW161KV | 85604 | | ||||
| 4 | 5 | 2 | 4 | ZF | B | 218-0313-010 | F5491 | | ||||
| 4 | 5 | 2 | 4 | ZF | A | 222-4270-160 | F5491 | | ||||
| 4 | 5 | 2 | 5 | 9Z | D | 218-0313-010 | 13499 | | ||||
Number is totally in-the-clear (without modification) as originally configured by the manufacturer, design control activity, or supplier.
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the technical documentation.
DLIS-K, Battle Creek, MI 49037-3084
Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.
Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.
France
Manufacturer and/or reference number are not authorized for procurement. NOTE: This code may be used for obsolete or informative reference numbers only.
Manufacturer and reference number are authorized for procurement. Under this reference number items can be procured only from the manufacturer identified by the NCAGE. NOTE: This code may only be used for reference numbers originating from manufacturers' standards or catalogs or for copyrighted drawing numbers.
The reference number is represented by a drawing, but the drawing was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.
| ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
|---|---|---|---|---|---|---|---|---|
| 5 | 97 | 0 | 31 Jan 2000 |
An item authorized for procurement that has not yet been subject to item standardization.
DLIS-LFF, Battle Creek, MI 49037-3084
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
| Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No Variation. NMFC and UFCC Match.
| MRC | Decoded Requirement | Clear Text Reply |
|---|---|---|
| AKWC | Electrical Power Source Relationship | OPERATING |
| CBBL | Features Provided | EMI FILTER AND OVER VOLTAGE PROTECTOR |
| AYNH | Operating Ambient Temp Range | +0.1/+71.0 DEG CELSIUS |
| CWHF | Output Connection Quantity | 1 MULTIPLE POWER OUTPUTS W/IDENTICAL RATINGS |
| CWHJ | Output Connection Type | PIN PLUG MULTIPLE POWER OUTPUTS W/IDENTICAL RATINGS |
| CWGH | Output Current Rating | 6.0 DC AMPERES MAXIMUM 1ST POWER OUTPUT |
| CWGH | Output Current Rating | 0.4 DC AMPERES MAXIMUM 3RD POWER OUTPUT |
| CWGH | Output Current Rating | 2.0 DC AMPERES MAXIMUM 2ND POWER OUTPUT |
| APPA | Output Voltage Rating | -15.0 DC VOLTS NOMINAL 3RD POWER OUTPUT |
| APPA | Output Voltage Rating | 5.0 DC VOLTS NOMINAL 1ST POWER OUTPUT |
| APPA | Output Voltage Rating | 15.0 DC VOLTS NOMINAL 2ND POWER OUTPUT |
| BGQR | Output Wattage Rating | 60.0 WATTS MAXIMUM MULTIPLE POWER OUTPUTS W/IDENTICAL RATINGS |
| APTQ | Input Frequency Rating | 47.0 HERTZ MINIMUM SINGLE OPERATING POWER RQMT AND 440.0 HERTZ MAXIMUM SINGLE OPERATING POWER RQMT |
| ANPM | Input Phase | SINGLE SINGLE OPERATING POWER RQMT |
| CWHM | Input Current Rating | 1.3 AC AMPERES MINIMUM SINGLE OPERATING POWER RQMT AND 0.8 AC AMPERES MAXIMUM SINGLE OPERATING POWER RQMT |
| APNX | Input Voltage Rating | 130.0 DC VOLTS MINIMUM 1ST ALTERNATE OPERATING POWER RQMT AND 370.0 DC VOLTS MAXIMUM 1ST ALTERNATE OPERATING POWER RQMT |
| APNX | Input Voltage Rating | 90.0 AC VOLTS MINIMUM 1ST OPERATING POWER RQMT AND 264.0 AC VOLTS MAXIMUM 1ST OPERATING POWER RQMT |
| CWWY | Power Supply Efficiency Line | 72.0 |
| ABKW | Overall Height | 1.500 INCHES NOMINAL |
| ABHP | Overall Length | 6.300 INCHES NOMINAL |
| ABMK | Overall Width | 3.940 INCHES NOMINAL |
| FEAT | Special Features | STORAGE TEMPERATURE MINUS 40.0 DEGC TO 85.0 DEGC |
| CWKG | Ventilation Design Type | CONVECTION |