6130-01-475-9437

POWER SUPPLY


6130-01-475-9437 (6130014759437, 014759437)
Part Number (1 listing): E1401-69202
Summary

FSG 61 / FSC 6130

DEMIL: Q

DEMIL INT: 6

HMIC: N

Date Created: 19 Jun 2000

MSDS: None

Hazmat: None

Export License Required:
Munitions List Item or Commerce Control List Item

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 6130-01-475-9437 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
E1401-692023 - Design Control Reference2 - Production ItemHEWLETT PACKARD CO  28480    CAGE 28480  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.


FLIS - SEG A - IDENTIFICATION | NSN 6130-01-475-9437 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
616130014759437A3990000740X46QNBA019 Jun 2000
Code Definitions

61

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electric Wire, and Power and Distribution Equipment

6130

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Converters, Electrical, Nonrotating

014759437

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 6130-01-475-9437

A39900

Federal Item Identification Guide (FIIG_4065)

00740

Item Naming Code (INC_4080)

19 Jun 2000

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

4

Type of Item Identification (TYP_II_4820)


Partial Descriptive Item Identification (Type 1 Concept)

6

Reference / Partial Descriptive Method Reason Code (RPDMRC_4765)


An approved item name and FIIG may exist, but it has previously been established and documented that industry refuses to provide the technical data sufficient for preparation on a full descriptive method item identification based on policy, restricted or proprietary data rights, nonexistence of technical data, etc.

Q

Demilitarization Code (DEMIL_CD_0167)


CCLI — Commerce Control List Item Demilitarization not required. CCLI are dual-use (military, commercial, and other strategic uses) items under the jurisdiction of the Bureau of Export Administration, U.S. Department of Commerce, through the Export Administration Regulations. The types of items under the Commerce Control List (CCL) are commodities (i.e., equipment, materials, electronics, propulsion systems, etc.), software, and technology. The CCL does not include those items exclusively controlled by another department or agency of the U.S. Government.

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

B

Electrostatic Discharge Code (ESD_EMI_CD_2043)


Represents items with ESD sensitivity.

A

Precious Metals Indicator Code (PMIC_0802)


Item does not contain Precious Metal.

0

ADPE Identification Code (ADPEC_0801)


Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)


FLIS - SEG B - MOE RULE DATA | NSN 6130-01-475-9437 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
FUU400FDFH1 Jun 2000
ZG011 May 2006
Code Definitions

0

Acquisition Method Code (AMC_2871)


Not Established

F

Nonconsumable Item Material Support Code (NIMSC_0076)


An activity within the Air Force is providing depot maintenance support.

D

Item Management Code (IMC_2744)


Major End Items of Equipment: Items of such importance to the operations readiness of operating units that they are subject to continuing centralized individual item management and asset control throughout all command and support echelons.

FHDSOR

Depot Source of Repair Codes (DSOR_0903)


Ogden Air Logistics Center (OO-ALC), Hill AFB, UT


FLIS - SEG C - REFERENCE NUMBER | NSN 6130-01-475-9437 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
322ZZE1401-69202  28480   CAGE/28480
Code Definitions

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

2

Document Availability Code (DAC_2640)


The reference number is represented by a drawing and the drawing was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the drawing.

ZZ

Reference Number Action Activity Code (RNAAC_2900)


USA


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 6130-01-475-9437 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
597019 Jun 2000
Code Definitions

5

Item Standardization Code (ISC_2650)


An item authorized for procurement that has not yet been subject to item standardization.

97

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


DLIS-LFF, Battle Creek, MI 49037-3084

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

19 Jun 2000

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 6130-01-475-9437 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
TK658Z9AHZM062900X35110RECTIFIERS-NOI-BATTERY-ELIMINATORS
Code Definitions

TK

Originating Activity Code (ORIG_ACTY_CD_4210)


HQ AFMC/GLSC 401 SCM/GUMB, Wright-Patterson AFB, OH 45433-5000

658

Water Commodity Code (WRT_CMDTY_CD_9275)


Electical Appliances, Small

Z

Type Cargo Code (TYPE_CGO_CD_9260)


No special type of cargo code applicable

9

Special Handling Code (SP_HDLG_CD_9240)


No special handling required

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

H

Air Commodity Code (AIR_CMTY_HDLG_9215)


Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.

Z

Air Special Handling Code (AIR_CMTY_HDLG_9215)


No special handling required.

M

Less Than Truckload (CLAS_RTNG_CD_2770)


85

062900

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

X

NMFC Sub Item Number (SUB_ITM_NBR_0861)

35110

Uniform Freight Classification (UFC_CD_MODF_3040)

RECTIFIERS-NOI-BATTERY-ELIMINATORS

Freight Description (FRT_DESC_4020)

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG H - MANAGEMENT DATA | NSN 6130-01-475-9437 Submit RFQ
Unit PriceMOESOSAACCIICQUPReparabilityUISLC
DFFGZMU1TEA0
Code Definitions

FGZ

Source of Supply (SOS_CD_3690) or Source of Supply Modifier (SOSM_CD_2948)


Ogden Air Logistics Center, 5851 F Ave, Hill AFB, UT 84056-5713

M

Acquisition Advice Code (AAC_2507)


RESTRICTED REQUISITIONS-MAJOR OVERHAUL (Service/Agency use only.) Items (Assemblies and/or component parts) which for lack of specialized tools, test equipment, etc., can be used only by major overhaul activities. Base, post, camp or station activities will not requisition unless authorized to perform major overhaul function.

U

Controlled Item Inventory Code (CIIC_2863)


Unclassified

1

Quantity Unit Pack (QUP_6106)


1

T

Reparability Code (REP_CD_DLA_2934 / REP_CD_CG_0709 / ERRC_CD_AF_2655 / RECOV_CD_MC_2891 / RECOV_CD_AR_2892 / MAT_CTL_NVY_2832)


AIR FORCE ERRC XD2: AF Recoverable Assembly Management System (AFRAMS); NAVY: Terminal Items

EA

Unit of Issue (UI_3050)


Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.

0

Shelf Life Code (SLC_2943)


TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.

DF

Service / Agency Code (MOE_CD_2833)


Department of the Air Force


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 6130-01-475-9437 Submit RFQ
MRCDecoded RequirementClear Text Reply
AGAVEnd Item IdentificationMMIII MISSILE GUIDANCE SET,LGM-30G
AYNHOperating Ambient Temp Range+0.1/+55.0 DEG CELSIUS
CWGHOutput Current Rating30.0 DC AMPERES MINIMUM 7TH POWER OUTPUT AND 35.0 DC AMPERES MAXIMUM 7TH POWER OUTPUT
CWGHOutput Current Rating60.0 DC AMPERES MINIMUM 1ST POWER OUTPUT AND 65.0 DC AMPERES MAXIMUM 1ST POWER OUTPUT
CWGHOutput Current Rating60.0 DC AMPERES MINIMUM 6TH POWER OUTPUT AND 65.0 DC AMPERES MAXIMUM 6TH POWER OUTPUT
CWGHOutput Current Rating10.0 DC AMPERES MINIMUM 5TH POWER OUTPUT AND 12.0 DC AMPERES MAXIMUM 5TH POWER OUTPUT
CWGHOutput Current Rating12.0 DC AMPERES MINIMUM 3RD POWER OUTPUT AND 14.0 DC AMPERES MAXIMUM 3RD POWER OUTPUT
CWGHOutput Current Rating12.0 DC AMPERES MINIMUM 4TH POWER OUTPUT AND 14.0 DC AMPERES MAXIMUM 4TH POWER OUTPUT
CWGHOutput Current Rating12.0 DC AMPERES MINIMUM 2ND POWER OUTPUT AND 14.0 DC AMPERES MAXIMUM 2ND POWER OUTPUT
APPAOutput Voltage Rating-12.0 DC VOLTS NOMINAL 3RD POWER OUTPUT
APPAOutput Voltage Rating-2.0 DC VOLTS NOMINAL 7TH POWER OUTPUT
APPAOutput Voltage Rating-24.0 DC VOLTS NOMINAL 5TH POWER OUTPUT
APPAOutput Voltage Rating-5.2 DC VOLTS NOMINAL 6TH POWER OUTPUT
APPAOutput Voltage Rating5.0 DC VOLTS NOMINAL 1ST POWER OUTPUT
APPAOutput Voltage Rating12.0 DC VOLTS NOMINAL 2ND POWER OUTPUT
APPAOutput Voltage Rating24.0 DC VOLTS NOMINAL 4TH POWER OUTPUT
APTQInput Frequency Rating400.0 HERTZ NOMINAL SINGLE OPERATING POWER RQMT
ABKWOverall Height16.800 INCHES NOMINAL
ABHPOverall Length23.700 INCHES NOMINAL
ABMKOverall Width12.200 INCHES NOMINAL


Back to Top