| Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
|---|---|---|---|---|---|
| 5881 | 3 - Design Control Reference | 2 - Production Item | INTEGRATED POWER SYSTEMS LLC | 03526 | |
| 0N659029-1 | 7 - Vendor Item Drawing Reference | 2 - Production Item | NATIONAL SECURITY AGENCY | 98230 | |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
Vendor Item Drawing Reference (formerly Specification Control Reference). The number assigned by a design activity to a drawing that is not item-identifying, but which delineates existing commercial or vendor-developed items meeting all engineering and test requirements specified, without imposing additional test/engineering requirements not normally provided by the vendor(s). Includes only those drawings which meet the definition for Vendor Item Drawing in MIL-STD 100. Vendor Item Drawing References are administrative control numbers and shall not be used as part identification numbers.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
| FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 61 | 6130 | 014799550 | A39900 | 00740 | Y | K | B | N | B | A | 0 | 2 Nov 2000 |
Electric Wire, and Power and Distribution Equipment
The item does not have a nuclear hardened feature but does have other critical feature(s) such as tolerance, fit restriction or application.
Full Descriptive - Reference Item Identification
MLI (Non-Significant Military Equipment – Non-SME) — Demilitarization not required — Trade Security Controls (TSCs) required at disposition.
Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.
Represents items with ESD sensitivity.
Item does not contain Precious Metal.
Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
| MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| FJ5N | 3 | C | F | 1 Nov 2000 | ||||||||||||||||||||||||||
Acquire directly from the actual manufacturer, whether or not the prime contractor is the actual manufacturer.
This part requires engineering source approval by the design control activity in order to maintain the quality of the part. An alternate source must qualify in accordance with the design control activity's procedures, as approved by the cognizant Government engineering activity. Valid AMCs: 1, 2, 3, 4 and 5.
Single Agency: Items assigned to a single agency other than the commodity oriented integrated manager for integrated management or control. (These include items controlled by the Energy Research and Development Administration or National Security Agency, or items assigned to the Army Tank-Automotive Command (TACOM) for integrated management.)
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
The reference number is represented by a drawing and the drawing was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the drawing upon request.
USA
Vendor Item Drawing Reference (formerly Specification Control Reference). The number assigned by a design activity to a drawing that is not item-identifying, but which delineates existing commercial or vendor-developed items meeting all engineering and test requirements specified, without imposing additional test/engineering requirements not normally provided by the vendor(s). Includes only those drawings which meet the definition for Vendor Item Drawing in MIL-STD 100. Vendor Item Drawing References are administrative control numbers and shall not be used as part identification numbers.
The reference number is represented by a drawing and the drawing was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the drawing.
| ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
|---|---|---|---|---|---|---|---|---|
| 2 | TU | 0 | 3 Nov 2000 |
An item authorized for procurement which has been included in an item reduction study and which initially does not replace an item not authorized for procurement. In addition, in generic relationships, a code 2 item is related to a code 1 item.
AF Cataloging Agent DLIS-K, Battle Creek, MI 49037-3094
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
| Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| TU |
AF Cataloging Agent DLIS-K, Battle Creek, MI 49037-3094
No Variation. NMFC and UFCC Match.
Air Force Cryptologic Support Group, 230 Hall Blvd, Bldg 2028, San Antonio, TX 78243-7081
DoD INTEGRATED MATERIEL-MANAGED, STOCKED, AND ISSUED. Issue, transfer, or shipment is not subject to specialized controls other than those imposed by the Integrated Materiel Manager/Service supply policy. 1. The item is centrally managed, stocked, and issued. 2. Requisitions must contain the fund citation required to acquire the item. Requisitions will be submitted in accordance with Integrated Materiel Manager(IMM)/Service requisitioning procedures.
Unclassified
1
AIR FORCE ERRC XF3: Stock Fund (Except Munitions); NAVY: Perishable Subsistence Items
Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.
TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.
Department of the Air Force
| MRC | Decoded Requirement | Clear Text Reply |
|---|---|---|
| AKWC | Electrical Power Source Relationship | OPERATING |
| AGAV | End Item Identification | KOK-13A |
| CRTL | Criticality Code Justification | FEAT |
| CWHF | Output Connection Quantity | 1 MULTIPLE POWER OUTPUTS W/IDENTICAL RATINGS |
| CWHJ | Output Connection Type | CONNECTOR, RECEPTACLE 1ST POWER OUTPUT |
| CWGH | Output Current Rating | 0.0 DC AMPERES MINIMUM 1ST POWER OUTPUT AND 7.0 DC AMPERES MAXIMUM 1ST POWER OUTPUT |
| CWGH | Output Current Rating | 0.0 DC MILLIAMPERES MINIMUM 2ND POWER OUTPUT AND 100.0 DC MILLIAMPERES MAXIMUM 2ND POWER OUTPUT |
| APPA | Output Voltage Rating | 10.0 DC VOLTS NOMINAL 2ND POWER OUTPUT |
| APPA | Output Voltage Rating | 5.0 DC VOLTS NOMINAL 1ST POWER OUTPUT |
| APTQ | Input Frequency Rating | 47.0 HERTZ MINIMUM SINGLE OPERATING POWER RQMT AND 440.0 HERTZ MAXIMUM SINGLE OPERATING POWER RQMT |
| ANPM | Input Phase | SINGLE SINGLE OPERATING POWER RQMT |
| APNX | Input Voltage Rating | 115.0 AC POUNDS PER HOUR WET SINGLE OPERATING POWER RQMT |
| ABKW | Overall Height | 3.020 INCHES MAXIMUM |
| ABHP | Overall Length | 8.000 INCHES NOMINAL |
| ABMK | Overall Width | 4.020 INCHES MAXIMUM |
| FEAT | Special Features | E.S.D. CRITICAL UNIT |