6130-01-504-5885

INVERTER,POWER,STATIC


6130-01-504-5885 (6130015045885, 015045885)
Part Numbers (2 listings): PC251-123A | A8409900 |
Summary

FSG 61 / FSC 6130

DEMIL: A

DEMIL INT: 1

HMIC: N

Date Created: 3 Feb 2003

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 6130-01-504-5885 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
PC251-123A3 - Design Control Reference2 - Production ItemMARATHONNORCO AEROSPACE, INC.  74025      
A84099005 - Replaced / Discontinued2 - Production ItemASE SPA  A9217      
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

5 - Replaced / Discontinued

Reference Number Category Code (DRN_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.


FLIS - SEG A - IDENTIFICATION | NSN 6130-01-504-5885 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
616130015045885A3990022284X46ANAA03 Feb 2003
Code Definitions

61

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electric Wire, and Power and Distribution Equipment

6130

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Converters, Electrical, Nonrotating

015045885

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 6130-01-504-5885

A39900

Federal Item Identification Guide (FIIG_4065)

22284

Item Naming Code (INC_4080)

3 Feb 2003

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

4

Type of Item Identification (TYP_II_4820)


Partial Descriptive Item Identification (Type 1 Concept)

6

Reference / Partial Descriptive Method Reason Code (RPDMRC_4765)


An approved item name and FIIG may exist, but it has previously been established and documented that industry refuses to provide the technical data sufficient for preparation on a full descriptive method item identification based on policy, restricted or proprietary data rights, nonexistence of technical data, etc.

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

A

Electrostatic Discharge Code (ESD_EMI_CD_2043)


No known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity.

A

Precious Metals Indicator Code (PMIC_0802)


Item does not contain Precious Metal.

0

ADPE Identification Code (ADPEC_0801)


Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)


FLIS - SEG B - MOE RULE DATA | NSN 6130-01-504-5885 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
ZR011 Feb 2003
Code Definitions

FLIS - SEG C - REFERENCE NUMBER | NSN 6130-01-504-5885 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
43249ZDPC251-123A  74025  
4521ZRAA8409900  A9217  
Code Definitions

4

Reference Number Format Code (RNFC_2920)


Number is totally in-the-clear (without modification) as originally configured by the manufacturer, design control activity, or supplier.

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

4

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the technical documentation.

9Z

Reference Number Action Activity Code (RNAAC_2900)


DLIS-K, Battle Creek, MI 49037-3084

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.

5

Reference Number Category Code (RNCC_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

1

Document Availability Code (DAC_2640)


The reference number is represented by a drawing and the drawing was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the drawing upon request.

ZR

Reference Number Action Activity Code (RNAAC_2900)


Italy

A

Reference Number Status Code (RNSC_2923)


Manufacturer and reference number are authorized for procurement. Under this reference number items can be procured only from the manufacturer identified by the NCAGE. NOTE: This code may only be used for reference numbers originating from manufacturers' standards or catalogs or for copyrighted drawing numbers.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 6130-01-504-5885 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
59703 Feb 2003
Code Definitions

5

Item Standardization Code (ISC_2650)


An item authorized for procurement that has not yet been subject to item standardization.

97

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


DLIS-LFF, Battle Creek, MI 49037-3084

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

3 Feb 2003

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 6130-01-504-5885 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
AM
Code Definitions

AM

Originating Activity Code (ORIG_ACTY_CD_4210)


U.S. Army Medical Materiel Agency, Frederick, MD 21701-5001

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 6130-01-504-5885 Submit RFQ
MRCDecoded RequirementClear Text Reply
AGAVEnd Item IdentificationFIXED WING AND HELICOPTER QUALIFIED
AKAEMaximum Operating Altitude Rating50000.0 FEET
AYNHOperating Ambient Temp Range-55.0/+71.0 DEG CELSIUS
APPAOutput Voltage Rating26.0 AC VOLTS NOMINAL 2ND POWER OUTPUT
APPAOutput Voltage Rating115.0 AC VOLTS NOMINAL 1ST POWER OUTPUT
CWHMInput Current Rating11.9 DC AMPERES NOMINAL 1ST OPERATING POWER RQMT
APNXInput Voltage Rating24.0 DC VOLTS MINIMUM 2ND OPERATING POWER RQMT AND 32.0 DC VOLTS MAXIMUM 2ND OPERATING POWER RQMT
APNXInput Voltage Rating28.0 DC VOLTS NOMINAL 1ST OPERATING POWER RQMT
AMQYInstallation DesignBOLT
ABKWOverall Height69.9 MILLIMETERS NOMINAL
ABHPOverall Length177.8 MILLIMETERS NOMINAL
ABMKOverall Width127.0 MILLIMETERS NOMINAL
CXCYPart Name Assigned By Controlling AgencyPC-251-123A LIGHTWEIGHT STATIC INVERTER
FEATSpecial FeaturesOUTPUT CONFIGURATION MONOPHASE SINEWAVE; EFFICIENCY 75 PCT NOMINAL; UNIT HAS REVERSE POLARITY PROTECTION; FREQUENCY MONITOR AUTOMATICALLY SHUTS THE INVERTER OFF SHOULD THE FREQUENCY DRIFT BELOW 370 HZ OR ABOVE 430 HZ; FAULTMONITOR PROVIDES 27 VDC OUTPUT AT 100 MA TO AN ANNUNCIATOR DEVICE UNDER NORMAL CONDITION; NO POWER IS AVAILABLE UNDER FAULT CONDITIONS; COOLING HI-REL BLOWER; ENVIRONMENTAL CONDITIONS RFI EMISSION MEETS RTCA DO-160A CAT Z; MATING CONNECTOR MS3476L14-9S


Back to Top
Back to Top