6130-01-519-5332

POWER SUPPLY


6130-01-519-5332 (6130015195332, 015195332)
Part Numbers (3 listings): 787-904 | 831-101 | PS374121.01.5.840 |
Summary

FSG 61 / FSC 6130

DEMIL: A

DEMIL INT: 1

HMIC: N

Date Created: 22 Apr 2004

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 6130-01-519-5332 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
787-9043 - Design Control Reference2 - Production ItemWAGO CORPORATION  65996      
831-1015 - Replaced / Discontinued2 - Production ItemORBITAL SYSTEMS, LTD.  399N6      
PS374121.01.5.8407 - Vendor Item Drawing Reference2 - Production ItemCAE INC  35181      
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

5 - Replaced / Discontinued

Reference Number Category Code (DRN_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

7 - Vendor Item Drawing Reference

Reference Number Category Code (DRN_2910)


Vendor Item Drawing Reference (formerly Specification Control Reference). The number assigned by a design activity to a drawing that is not item-identifying, but which delineates existing commercial or vendor-developed items meeting all engineering and test requirements specified, without imposing additional test/engineering requirements not normally provided by the vendor(s). Includes only those drawings which meet the definition for Vendor Item Drawing in MIL-STD 100. Vendor Item Drawing References are administrative control numbers and shall not be used as part identification numbers.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.


FLIS - SEG A - IDENTIFICATION | NSN 6130-01-519-5332 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
616130015195332A3990000740X46ANAA022 Apr 2004
Code Definitions

61

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electric Wire, and Power and Distribution Equipment

6130

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Converters, Electrical, Nonrotating

015195332

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 6130-01-519-5332

A39900

Federal Item Identification Guide (FIIG_4065)

00740

Item Naming Code (INC_4080)

22 Apr 2004

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

4

Type of Item Identification (TYP_II_4820)


Partial Descriptive Item Identification (Type 1 Concept)

6

Reference / Partial Descriptive Method Reason Code (RPDMRC_4765)


An approved item name and FIIG may exist, but it has previously been established and documented that industry refuses to provide the technical data sufficient for preparation on a full descriptive method item identification based on policy, restricted or proprietary data rights, nonexistence of technical data, etc.

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

A

Electrostatic Discharge Code (ESD_EMI_CD_2043)


No known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity.

A

Precious Metals Indicator Code (PMIC_0802)


Item does not contain Precious Metal.

0

ADPE Identification Code (ADPEC_0801)


Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)


FLIS - SEG B - MOE RULE DATA | NSN 6130-01-519-5332 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
ZC011 Apr 2004
YJ011 May 2010
Code Definitions

FLIS - SEG C - REFERENCE NUMBER | NSN 6130-01-519-5332 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
43229ZD787-904  65996  
45249ZD831-101  399N6  
47229ZDPS374121.01.5.840  35181  
Code Definitions

4

Reference Number Format Code (RNFC_2920)


Number is totally in-the-clear (without modification) as originally configured by the manufacturer, design control activity, or supplier.

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

2

Document Availability Code (DAC_2640)


The reference number is represented by a drawing and the drawing was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the drawing.

9Z

Reference Number Action Activity Code (RNAAC_2900)


DLIS-K, Battle Creek, MI 49037-3084

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.

5

Reference Number Category Code (RNCC_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

4

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the technical documentation.

7

Reference Number Category Code (RNCC_2910)


Vendor Item Drawing Reference (formerly Specification Control Reference). The number assigned by a design activity to a drawing that is not item-identifying, but which delineates existing commercial or vendor-developed items meeting all engineering and test requirements specified, without imposing additional test/engineering requirements not normally provided by the vendor(s). Includes only those drawings which meet the definition for Vendor Item Drawing in MIL-STD 100. Vendor Item Drawing References are administrative control numbers and shall not be used as part identification numbers.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 6130-01-519-5332 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
597022 Apr 2004
Code Definitions

5

Item Standardization Code (ISC_2650)


An item authorized for procurement that has not yet been subject to item standardization.

97

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


DLIS-LFF, Battle Creek, MI 49037-3084

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

22 Apr 2004

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 6130-01-519-5332 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
DF
Code Definitions

DF

Originating Activity Code (ORIG_ACTY_CD_4210)


U.S. Army Tank Automotive Command, Warren, MI 48090

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 6130-01-519-5332 Submit RFQ
MRCDecoded RequirementClear Text Reply
AGAVEnd Item IdentificationCP140 FLIGHT SIMULATOR
AYNHOperating Ambient Temp Range-40.0/+60.0 DEG CELSIUS
CWGHOutput Current Rating10.0 DC AMPERES NOMINAL SINGLE POWER OUTPUT
APPAOutput Voltage Rating24.0 DC VOLTS MINIMUM SINGLE POWER OUTPUT AND 26.4 DC VOLTS MAXIMUM SINGLE POWER OUTPUT
BGQROutput Wattage Rating240.0 WATTS NOMINAL SINGLE POWER OUTPUT
CWHMInput Current Rating2.5 AC AMPERES NOMINAL SINGLE OPERATING POWER RQMT AND 1.3 DC AMPERES NOMINAL SINGLE OPERATING POWER RQMT
APNXInput Voltage Rating85.0 AC VOLTS MINIMUM SINGLE OPERATING POWER RQMT AND 264.0 AC VOLTS MAXIMUM SINGLE OPERATING POWER RQMT AND 90.0 DC VOLTS MINIMUM SINGLE OPERATING POWER RQMT AND 350.0 DC VOLTS MAXIMUM SINGLE OPERATING POWER RQMT
CWGZRipple Voltage At Full Load0.42 VOLTS RMS SINGLE POWER OUTPUT
ABKWOverall Height103.0 MILLIMETERS NOMINAL
ABHPOverall Length138.0 MILLIMETERS NOMINAL
ABMKOverall Width114.0 MILLIMETERS NOMINAL
CXCYPart Name Assigned By Controlling AgencyPOWER SUPPLY, DIN RAIL 24 VDC, 10 A, SINGLE OUTPUT
FEATSpecial FeaturesINPUT FUSE 6.3 A SLOW; FUNCTION INDICATOR LED, GREEN; EFFICIENCY, AC 230 V, 89 PCT; DEVIATION STATIC LOAD CHANGE 350 MV; DEVIATION DYNAMIC LOAD CHANGE 10-90 PCT 2.6-3.0 V; PEAK TO AVERAGE RIPPLE FACTOR 5 PCT; OUTPUT HOLD UP TIME 15 MS; OUTPUT PROTECTION MEASURES OVERLOAD AND SHORT CIRCUIT PROTECTION; DIELECTRIC STRENGTH INPUT/OUTPUT AC 3 KV; NOMINAL OPERATING MODE 100 PCT CONTINUOUS DUTY; RELATIVE HUMIDITY 93 PCT NO CONDENSATION; STORAGE TEMPERATURE M40.0-P100.0 DEG C; MOUNTING SYSTEM TO BE SNAPPED ONTO DIN RAIL IN ACCORDANCE WITH EN 50022, FOR VERTICAL MOUNTING, MODULAR


Back to Top