6130-01-519-5333

POWER SUPPLY


6130-01-519-5333 (6130015195333, 015195333)
Part Numbers (2 listings): S82K-01505 | PS302367.03.5.840 |
Summary

FSG 61 / FSC 6130

DEMIL: A

DEMIL INT: 1

HMIC: N

Date Created: 22 Apr 2004

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 6130-01-519-5333 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
S82K-015053 - Design Control Reference2 - Production ItemOMRON ELECTRONICS LLC  61964      
PS302367.03.5.8405 - Replaced / Discontinued2 - Production ItemCAE INC  35181      
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

5 - Replaced / Discontinued

Reference Number Category Code (DRN_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.


FLIS - SEG A - IDENTIFICATION | NSN 6130-01-519-5333 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
616130015195333A3990000740X46ANAA022 Apr 2004
Code Definitions

61

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electric Wire, and Power and Distribution Equipment

6130

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Converters, Electrical, Nonrotating

015195333

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 6130-01-519-5333

A39900

Federal Item Identification Guide (FIIG_4065)

00740

Item Naming Code (INC_4080)

22 Apr 2004

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

4

Type of Item Identification (TYP_II_4820)


Partial Descriptive Item Identification (Type 1 Concept)

6

Reference / Partial Descriptive Method Reason Code (RPDMRC_4765)


An approved item name and FIIG may exist, but it has previously been established and documented that industry refuses to provide the technical data sufficient for preparation on a full descriptive method item identification based on policy, restricted or proprietary data rights, nonexistence of technical data, etc.

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

A

Electrostatic Discharge Code (ESD_EMI_CD_2043)


No known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity.

A

Precious Metals Indicator Code (PMIC_0802)


Item does not contain Precious Metal.

0

ADPE Identification Code (ADPEC_0801)


Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)


FLIS - SEG B - MOE RULE DATA | NSN 6130-01-519-5333 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
ZC011 Apr 2004
YJ011 May 2010
Code Definitions

FLIS - SEG C - REFERENCE NUMBER | NSN 6130-01-519-5333 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
43229ZDS82K-01505  61964  
45229ZDPS302367.03.5.840  35181  
Code Definitions

4

Reference Number Format Code (RNFC_2920)


Number is totally in-the-clear (without modification) as originally configured by the manufacturer, design control activity, or supplier.

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

2

Document Availability Code (DAC_2640)


The reference number is represented by a drawing and the drawing was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the drawing.

9Z

Reference Number Action Activity Code (RNAAC_2900)


DLIS-K, Battle Creek, MI 49037-3084

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.

5

Reference Number Category Code (RNCC_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 6130-01-519-5333 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
597022 Apr 2004
Code Definitions

5

Item Standardization Code (ISC_2650)


An item authorized for procurement that has not yet been subject to item standardization.

97

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


DLIS-LFF, Battle Creek, MI 49037-3084

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

22 Apr 2004

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 6130-01-519-5333 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
DF
Code Definitions

DF

Originating Activity Code (ORIG_ACTY_CD_4210)


U.S. Army Tank Automotive Command, Warren, MI 48090

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 6130-01-519-5333 Submit RFQ
MRCDecoded RequirementClear Text Reply
AGAVEnd Item IdentificationCP140 FLIGHT SIMULATOR
AYNHOperating Ambient Temp Range-10.0/+100.0 DEG CELSIUS
CWGHOutput Current Rating2.5 AC AMPERES NOMINAL SINGLE POWER OUTPUT
APPAOutput Voltage Rating5.0 AC VOLTS NOMINAL SINGLE POWER OUTPUT
APTQInput Frequency Rating47.0 HERTZ MINIMUM SINGLE OPERATING POWER RQMT AND 450.0 HERTZ MAXIMUM SINGLE OPERATING POWER RQMT
CWHMInput Current Rating0.45 AC AMPERES MINIMUM SINGLE OPERATING POWER RQMT AND 25.0 AC AMPERES MAXIMUM SINGLE OPERATING POWER RQMT
APNXInput Voltage Rating120.0 AC POUNDS PER HOUR DRY SINGLE OPERATING POWER RQMT AND 240.0 AC POUNDS PER HOUR WITH RETAINING CHAIN SINGLE OPERATING POWER RQMT
ABKWOverall Height1.770 INCHES NOMINAL
ABHPOverall Length3.780 INCHES NOMINAL
ABMKOverall Width2.950 INCHES NOMINAL
CXCYPart Name Assigned By Controlling AgencySWITCHING POWER SUPPLY
FEATSpecial FeaturesEFFICIENCY 70-86 PCT; LIFE EXPECTANCY 8 YEARS MIN WITH STANDARD INSTALLATION AT 40 DEG C AT THE RATED INPUT WITH A 50 PCT LOAD; LEAKAGE CURRENT 120 V INPUT 0.5 MA MAX;, 240 V INPUT 1 MA MAX; INRUSH CURRENT 120 V INPUT 15 A MAX, 240 V INPUT 30 A MAX; NOISE FILTER; VOLTAGE ADJUSTMENT RANGE PORM 10 PCT; RIPPLE 2 PCT P-P MAX; INPUT VARIATION INFLUENCE 0.5 PCT MAX; LOAD VARIATION INFLUENCE 1.5 PCT MAX; TEMPERATURE VARIATION INFLUENCE 0.05 PCT DEG C MAX; RISE TIME 100 MS MAX; HOLD TIME 20 MS MIN; OVERLOAD PROTECTION 105 PCT MIN OF RATED LOAD CURRENT, INVERTED L DROP TYPE, AUTOMATIC RESET; STORAGE AMBIENT TEMPERATURE M25.0-P65.0 DEG C; AMBIENT HUMIDITY OPERATING 25-85 PCT, STORAGE 25-90 PCT; DIELECTRIC STRENGTH 2,200 VAC, 50-60 HZ FOR 1 MIN, 2,000 VAC, 50-60 HZ FOR 1 MIN; OUTPUT INDICATOR GREEN LED; 250 G MAX WEIGHT


Back to Top