6130-01-528-4656

POWER SUPPLY


6130-01-528-4656 (6130015284656, 015284656)
Part Number (1 listing): RKW24-6.5K
Summary

FSG 61 / FSC 6130

DEMIL: B

DEMIL INT: 3

HMIC: N

Date Created: 14 Mar 2005

MSDS: None

Hazmat: None

Export License Required:
Critical Munitions List Item or Sensitive Commerce Control List Item

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 6130-01-528-4656 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
RKW 24-6.5K3 - Design Control Reference2 - Production ItemKEPCO, INC.  85604    CAGE 85604  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.


FLIS - SEG A - IDENTIFICATION | NSN 6130-01-528-4656 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
616130015284656A3990000740X1BNAA014 Mar 2005
Code Definitions

61

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electric Wire, and Power and Distribution Equipment

6130

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Converters, Electrical, Nonrotating

015284656

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 6130-01-528-4656

A39900

Federal Item Identification Guide (FIIG_4065)

00740

Item Naming Code (INC_4080)

14 Mar 2005

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

1

Type of Item Identification (TYP_II_4820)


Full Descriptive Item Identification

B

Demilitarization Code (DEMIL_CD_0167)


MLI (Non-Significant Military Equipment – Non-SME) — Demilitarization not required — Trade Security Controls (TSCs) required at disposition.

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

A

Electrostatic Discharge Code (ESD_EMI_CD_2043)


No known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity.

A

Precious Metals Indicator Code (PMIC_0802)


Item does not contain Precious Metal.

0

ADPE Identification Code (ADPEC_0801)


Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)


FLIS - SEG B - MOE RULE DATA | NSN 6130-01-528-4656 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
YB011 Apr 2009
Code Definitions

FLIS - SEG C - REFERENCE NUMBER | NSN 6130-01-528-4656 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
43249ZDRKW 24-6.5K  85604   CAGE/85604
Code Definitions

4

Reference Number Format Code (RNFC_2920)


Number is totally in-the-clear (without modification) as originally configured by the manufacturer, design control activity, or supplier.

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

4

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the technical documentation.

9Z

Reference Number Action Activity Code (RNAAC_2900)


DLIS-K, Battle Creek, MI 49037-3084

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 6130-01-528-4656 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
597014 Mar 2005
Code Definitions

5

Item Standardization Code (ISC_2650)


An item authorized for procurement that has not yet been subject to item standardization.

97

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


DLIS-LFF, Battle Creek, MI 49037-3084

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

14 Mar 2005

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 6130-01-528-4656 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
Code Definitions

01

Originating Activity Code (ORIG_ACTY_CD_4210)


Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 6130-01-528-4656 Submit RFQ
MRCDecoded RequirementClear Text Reply
AKWCElectrical Power Source RelationshipOPERATING
AYNHOperating Ambient Temp Range-10.0/+71.0 DEG CELSIUS
CWGNOutput PhaseSINGLE SINGLE POWER OUTPUT
CWGHOutput Current Rating6.5 DC AMPERES NOMINAL SINGLE POWER OUTPUT
APPAOutput Voltage Rating19.2 DC VOLTS MINIMUM SINGLE POWER OUTPUT AND 26.4 DC VOLTS MAXIMUM SINGLE POWER OUTPUT
APTQInput Frequency Rating47.0 HERTZ MINIMUM 1ST OPERATING POWER RQMT AND 66.0 HERTZ MAXIMUM 1ST OPERATING POWER RQMT
APTQInput Frequency Rating47.0 HERTZ MINIMUM 2ND OPERATING POWER RQMT AND 66.0 HERTZ MAXIMUM 2ND OPERATING POWER RQMT
CWHMInput Current Rating2.0 AC AMPERES MAXIMUM 1ST OPERATING POWER RQMT
CWHMInput Current Rating2.0 AC AMPERES MAXIMUM 2ND OPERATING POWER RQMT
ANPMInput PhaseSINGLE 1ST OPERATING POWER RQMT OR TWO 1ST OPERATING POWER RQMT
ANPMInput PhaseSINGLE 2ND OPERATING POWER RQMT
APNXInput Voltage Rating110.0 DC POUNDS PER HOUR DRY 2ND OPERATING POWER RQMT AND 370.0 DC POUNDS PER HOUR WITH RETAINING CHAIN 2ND OPERATING POWER RQMT
APNXInput Voltage Rating85.0 AC POUNDS PER HOUR DRY 1ST OPERATING POWER RQMT AND 265.0 AC POUNDS PER HOUR WITH RETAINING CHAIN 1ST OPERATING POWER RQMT
ABKWOverall Height1.970 INCHES NOMINAL
ABHPOverall Length8.310 INCHES NOMINAL
ABMKOverall Width3.580 INCHES NOMINAL
CXCYPart Name Assigned By Controlling Agency150 WATT SINGLE OUTPUT, PFC, OPEN FRAME POWER SUPPLIES
CWKGVentilation Design TypeAMBIENT AIR


Back to Top
Back to Top