6130-01-529-6222

POWER SUPPLY


6130-01-529-6222 (6130015296222, 015296222)
Part Number (1 listing): 25-74471-12
Summary

FSG 61 / FSC 6130

DEMIL: C

DEMIL INT: 1

HMIC: N

Date Created: 22 Apr 2005

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 6130-01-529-6222 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
25-74471-123 - Design Control Reference2 - Production ItemTHE BOEING COMPANY  81205    CAGE 81205  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.


FLIS - SEG A - IDENTIFICATION | NSN 6130-01-529-6222 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
616130015296222A3990000740M43CNBU022 Apr 2005
Code Definitions

61

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electric Wire, and Power and Distribution Equipment

6130

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Converters, Electrical, Nonrotating

015296222

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 6130-01-529-6222

A39900

Federal Item Identification Guide (FIIG_4065)

00740

Item Naming Code (INC_4080)

22 Apr 2005

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

M

Item Criticality (CRITL_CD_FIIG_3843)


The item is specifically designed to be or selected as being nuclear hard. In addition the item has other critical features such as tolerance, fit restrictions or application.

4

Type of Item Identification (TYP_II_4820)


Partial Descriptive Item Identification (Type 1 Concept)

3

Reference / Partial Descriptive Method Reason Code (RPDMRC_4765)


An approved item name and FIIG exist but the item involved is so unique in design that it cannot be fully described in accordance with the FIIG.

C

Demilitarization Code (DEMIL_CD_0167)


MLI (SME) — Remove and/or demilitarize installed key point(s) as prescribed in DOD 4160.21-M-1 — Defense Demilitarization Manual, or lethal parts, components and accessories

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

B

Electrostatic Discharge Code (ESD_EMI_CD_2043)


Represents items with ESD sensitivity.

U

Precious Metals Indicator Code (PMIC_0802)


Precious Metal Content is unknown.

0

ADPE Identification Code (ADPEC_0801)


Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)


FLIS - SEG B - MOE RULE DATA | NSN 6130-01-529-6222 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
FUU43BFDFH1 Apr 2005
Code Definitions

3

Acquisition Method Code (AMC_2871)


Acquire directly from the actual manufacturer, whether or not the prime contractor is the actual manufacturer.

B

Acquisition Method Suffix Code (AMSC_2876)


Acquisition of this part is restricted to source(s) specified on "Source Control", "Altered Item" or "Selected Item" drawings/documents. Valid AMCs: 1, 2, 3, 4 and 5.

F

Nonconsumable Item Material Support Code (NIMSC_0076)


An activity within the Air Force is providing depot maintenance support.

D

Item Management Code (IMC_2744)


Major End Items of Equipment: Items of such importance to the operations readiness of operating units that they are subject to continuing centralized individual item management and asset control throughout all command and support echelons.

FHDSOR

Depot Source of Repair Codes (DSOR_0903)


Ogden Air Logistics Center (OO-ALC), Hill AFB, UT


FLIS - SEG C - REFERENCE NUMBER | NSN 6130-01-529-6222 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
321ZZ25-74471-12  81205   CAGE/81205
Code Definitions

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

1

Document Availability Code (DAC_2640)


The reference number is represented by a drawing and the drawing was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the drawing upon request.

ZZ

Reference Number Action Activity Code (RNAAC_2900)


USA


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 6130-01-529-6222 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
597022 Apr 2005
Code Definitions

5

Item Standardization Code (ISC_2650)


An item authorized for procurement that has not yet been subject to item standardization.

97

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


DLIS-LFF, Battle Creek, MI 49037-3084

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

22 Apr 2005

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 6130-01-529-6222 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
TK65839AHZM062900X35110RECTIFIERS-NOI-BATTERY-ELIMINATORS
Code Definitions

TK

Originating Activity Code (ORIG_ACTY_CD_4210)


HQ AFMC/GLSC 401 SCM/GUMB, Wright-Patterson AFB, OH 45433-5000

658

Water Commodity Code (WRT_CMDTY_CD_9275)


Electical Appliances, Small

3

Type Cargo Code (TYPE_CGO_CD_9260)


Electrostatic Sensitive Device (ESD), subject to damage caused by electrostatic discharge. (See DoD 4500.32-R, Volume 1, Appendix A, Section I for additional information on ESD devices).

9

Special Handling Code (SP_HDLG_CD_9240)


No special handling required

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

H

Air Commodity Code (AIR_CMTY_HDLG_9215)


Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.

Z

Air Special Handling Code (AIR_CMTY_HDLG_9215)


No special handling required.

M

Less Than Truckload (CLAS_RTNG_CD_2770)


85

062900

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

X

NMFC Sub Item Number (SUB_ITM_NBR_0861)

35110

Uniform Freight Classification (UFC_CD_MODF_3040)

RECTIFIERS-NOI-BATTERY-ELIMINATORS

Freight Description (FRT_DESC_4020)

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG H - MANAGEMENT DATA | NSN 6130-01-529-6222 Submit RFQ
Unit PriceMOESOSAACCIICQUPReparabilityUISLC
DFFGZC71TEA0
Code Definitions

FGZ

Source of Supply (SOS_CD_3690) or Source of Supply Modifier (SOSM_CD_2948)


Ogden Air Logistics Center, 5851 F Ave, Hill AFB, UT 84056-5713

C

Acquisition Advice Code (AAC_2507)


SERVICE/AGENCY-MANAGED (Service/Agency use only.) Issue, transfer, or shipment is not subject to specialized controls other than those imposed by individual Services supply policy. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with Service requisitioning procedures.

7

Controlled Item Inventory Code (CIIC_2863)


Non-Sensitive (SRC-N/A) — UNCLASSIFIED AA&E or Items assigned a Demilitarization Code other than A, B, Q or P for which another CIIC is inappropriate. (NOTE: The loss, theft, unlawful 011disposition, and/or recovery of an item with CIIC 7 will be investigated in accordance with DoD 4000.25-2-M and DoD 7200.14–R, Volume 12, Chapter7).

1

Quantity Unit Pack (QUP_6106)


1

T

Reparability Code (REP_CD_DLA_2934 / REP_CD_CG_0709 / ERRC_CD_AF_2655 / RECOV_CD_MC_2891 / RECOV_CD_AR_2892 / MAT_CTL_NVY_2832)


AIR FORCE ERRC XD2: AF Recoverable Assembly Management System (AFRAMS); NAVY: Terminal Items

EA

Unit of Issue (UI_3050)


Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.

0

Shelf Life Code (SLC_2943)


TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.

DF

Service / Agency Code (MOE_CD_2833)


Department of the Air Force


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 6130-01-529-6222 Submit RFQ
MRCDecoded RequirementClear Text Reply
APPAOutput Voltage Rating5.1 DC VOLTS NOMINAL 1ST POWER OUTPUT
APPAOutput Voltage Rating6.0 DC VOLTS NOMINAL 2ND POWER OUTPUT
APPAOutput Voltage Rating6.0 DC VOLTS NOMINAL 3RD POWER OUTPUT
APPAOutput Voltage Rating2.0 DC VOLTS NOMINAL 4TH POWER OUTPUT
APPAOutput Voltage Rating12.0 DC VOLTS NOMINAL 5TH POWER OUTPUT
APPAOutput Voltage Rating17.0 DC VOLTS NOMINAL 6TH POWER OUTPUT
APPAOutput Voltage Rating28.0 DC VOLTS NOMINAL 7TH POWER OUTPUT
APPAOutput Voltage Rating41.0 DC VOLTS NOMINAL 8TH POWER OUTPUT
APPAOutput Voltage Rating70.0 DC VOLTS NOMINAL 9TH POWER OUTPUT
CWGHOutput Current Rating7.0 DC AMPERES NOMINAL 1ST POWER OUTPUT
CWGHOutput Current Rating3.2 DC AMPERES NOMINAL 2ND POWER OUTPUT
CWGHOutput Current Rating3.2 DC AMPERES NOMINAL 3RD POWER OUTPUT
CWGHOutput Current Rating4.0 DC AMPERES NOMINAL 4TH POWER OUTPUT
CWGHOutput Current Rating6.0 DC AMPERES NOMINAL 5TH POWER OUTPUT
CWGHOutput Current Rating75.0 DC AMPERES NOMINAL 6TH POWER OUTPUT
CWGHOutput Current Rating200.0 DC AMPERES NOMINAL 7TH POWER OUTPUT
CWGHOutput Current Rating10.0 DC AMPERES NOMINAL 8TH POWER OUTPUT
CWGHOutput Current Rating300.0 DC AMPERES NOMINAL 9TH POWER OUTPUT
AKWCElectrical Power Source RelationshipOPERATING
AKAEMaximum Operating Altitude Rating7000.0 FEET
ABHPOverall Length21.000 INCHES NOMINAL
ABMKOverall Width19.000 INCHES NOMINAL
CRTLCriticality Code JustificationNHCF
NHCFNuclear Hardness Critical FeatureHARDENED
AGAVEnd Item IdentificationLGM-30 MINUTEMAN


Back to Top