6130-01-578-9931

POWER SUPPLY


6130-01-578-9931 (6130015789931, 015789931)
Part Number (1 listing): SUINT1000RTXL2UA
Summary

FSG 61 / FSC 6130

DEMIL: A

DEMIL INT: 1

HMIC: N

Date Created: 27 Oct 2009

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 6130-01-578-9931 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
SUINT1000RTXL2UA3 - Design Control Reference2 - Production ItemTRIPPE MANUFACTURING COMPANY  65836      
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.


FLIS - SEG A - IDENTIFICATION | NSN 6130-01-578-9931 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
616130015789931A3990000740X46ANAA027 Oct 2009
Code Definitions

61

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electric Wire, and Power and Distribution Equipment

6130

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Converters, Electrical, Nonrotating

015789931

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 6130-01-578-9931

A39900

Federal Item Identification Guide (FIIG_4065)

00740

Item Naming Code (INC_4080)

27 Oct 2009

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

4

Type of Item Identification (TYP_II_4820)


Partial Descriptive Item Identification (Type 1 Concept)

6

Reference / Partial Descriptive Method Reason Code (RPDMRC_4765)


An approved item name and FIIG may exist, but it has previously been established and documented that industry refuses to provide the technical data sufficient for preparation on a full descriptive method item identification based on policy, restricted or proprietary data rights, nonexistence of technical data, etc.

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

A

Electrostatic Discharge Code (ESD_EMI_CD_2043)


No known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity.

A

Precious Metals Indicator Code (PMIC_0802)


Item does not contain Precious Metal.

0

ADPE Identification Code (ADPEC_0801)


Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)


FLIS - SEG B - MOE RULE DATA | NSN 6130-01-578-9931 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
WU011 Oct 2009
Code Definitions

FLIS - SEG C - REFERENCE NUMBER | NSN 6130-01-578-9931 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
43249ZDSUINT1000RTXL2UA  65836  
Code Definitions

4

Reference Number Format Code (RNFC_2920)


Number is totally in-the-clear (without modification) as originally configured by the manufacturer, design control activity, or supplier.

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

4

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the technical documentation.

9Z

Reference Number Action Activity Code (RNAAC_2900)


DLIS-K, Battle Creek, MI 49037-3084

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 6130-01-578-9931 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
597027 Oct 2009
Code Definitions

5

Item Standardization Code (ISC_2650)


An item authorized for procurement that has not yet been subject to item standardization.

97

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


DLIS-LFF, Battle Creek, MI 49037-3084

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

27 Oct 2009

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 6130-01-578-9931 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
Code Definitions

01

Originating Activity Code (ORIG_ACTY_CD_4210)


Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 6130-01-578-9931 Submit RFQ
MRCDecoded RequirementClear Text Reply
AYNHOperating Ambient Temp Range+35.0/+104.0 DEG FAHRENHEIT
CWGHOutput Current Rating1000.0 AC VOLT-AMPERE NOMINAL SINGLE POWER OUTPUT
APTSOutput Frequency Rating50.0 HERTZ MINIMUM SINGLE POWER OUTPUT AND 60.0 HERTZ MAXIMUM SINGLE POWER OUTPUT
APPAOutput Voltage Rating230.0 AC VOLTS NOMINAL SINGLE POWER OUTPUT
BGQROutput Wattage Rating800.0 WATTS NOMINAL SINGLE POWER OUTPUT
CWHMInput Current Rating4.2 AC AMPERES NOMINAL 4TH OPERATING POWER RQMT
CWHMInput Current Rating4.6 AC AMPERES NOMINAL 3RD OPERATING POWER RQMT
CWHMInput Current Rating4.9 AC AMPERES NOMINAL 2ND OPERATING POWER RQMT
CWHMInput Current Rating5.1 AC AMPERES NOMINAL 1ST OPERATING POWER RQMT
APNXInput Voltage Rating200.0 AC VOLTS NOMINAL 1ST OPERATING POWER RQMT
APNXInput Voltage Rating220.0 AC VOLTS NOMINAL 2ND OPERATING POWER RQMT
APNXInput Voltage Rating230.0 AC VOLTS NOMINAL 3RD OPERATING POWER RQMT
APNXInput Voltage Rating240.0 AC VOLTS NOMINAL 4TH OPERATING POWER RQMT
AMQYInstallation DesignRACK
FEATSpecial FeaturesHOT-SWAPPABLE BATTERIES; COLD-START OPERATION; AUTOMATIC INVERTER BYPASS; POWER ALERT AND SOFTWARE CABLING; 2 IEC C13 TO C14 INTERCONNECTION CABLES; 6 OUTLETS; FAULT-TOLERANT AUTO BYPASS; ZERO TRANSFER RATE