6130-01-612-5594

RUGGEDISED DC UNINTERRUPTED POWER SUPPLY SYSTEM


6130-01-612-5594 (6130016125594, 016125594)
Part Number (1 listing): SUVT40KH4B4S
Summary

FSG 61 / FSC 6130

DEMIL: B

DEMIL INT: 3

HMIC: N

Date Created: 15 Oct 2012

MSDS: None

Hazmat: None

Export License Required:
Critical Munitions List Item or Sensitive Commerce Control List Item

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 6130-01-612-5594 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
SUVT40KH4B4S3 - Design Control Reference9 - No Longer UsedSCHNEIDER ELECTRIC IT CORPORATION  0MG77      
SUVT40KH4B4S5 - Replaced / Discontinued2 - Production ItemBAE SYSTEMS AUSTRALIA LTD  Z3522      
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

5 - Replaced / Discontinued

Reference Number Category Code (DRN_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

9 - No Longer Used

Reference Number Variation Code (DRN_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.


FLIS - SEG A - IDENTIFICATION | NSN 6130-01-612-5594 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
616130016125594A3990052201X43BNAA015 Oct 2012
Code Definitions

61

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electric Wire, and Power and Distribution Equipment

6130

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Converters, Electrical, Nonrotating

016125594

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 6130-01-612-5594

A39900

Federal Item Identification Guide (FIIG_4065)

52201

Item Naming Code (INC_4080)

15 Oct 2012

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

4

Type of Item Identification (TYP_II_4820)


Partial Descriptive Item Identification (Type 1 Concept)

3

Reference / Partial Descriptive Method Reason Code (RPDMRC_4765)


An approved item name and FIIG exist but the item involved is so unique in design that it cannot be fully described in accordance with the FIIG.

B

Demilitarization Code (DEMIL_CD_0167)


MLI (Non-Significant Military Equipment – Non-SME) — Demilitarization not required — Trade Security Controls (TSCs) required at disposition.

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

A

Electrostatic Discharge Code (ESD_EMI_CD_2043)


No known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity.

A

Precious Metals Indicator Code (PMIC_0802)


Item does not contain Precious Metal.

0

ADPE Identification Code (ADPEC_0801)


Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)


FLIS - SEG B - MOE RULE DATA | NSN 6130-01-612-5594 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
ZA011 Oct 2012
Code Definitions

FLIS - SEG C - REFERENCE NUMBER | NSN 6130-01-612-5594 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
43949ZDSUVT40KH4B4S  0MG77  
4524ZADSUVT40KH4B4S  Z3522  
Code Definitions

4

Reference Number Format Code (RNFC_2920)


Number is totally in-the-clear (without modification) as originally configured by the manufacturer, design control activity, or supplier.

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

9

Reference Number Variation Code (RNVC_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.

4

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the technical documentation.

9Z

Reference Number Action Activity Code (RNAAC_2900)


DLIS-K, Battle Creek, MI 49037-3084

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.

5

Reference Number Category Code (RNCC_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

ZA

Reference Number Action Activity Code (RNAAC_2900)


Australia


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 6130-01-612-5594 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
597015 Oct 2012
Code Definitions

5

Item Standardization Code (ISC_2650)


An item authorized for procurement that has not yet been subject to item standardization.

97

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


DLIS-LFF, Battle Creek, MI 49037-3084

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

15 Oct 2012

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 6130-01-612-5594 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
ZA
Code Definitions

ZA

Originating Activity Code (ORIG_ACTY_CD_4210)


Australia

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 6130-01-612-5594 Submit RFQ
MRCDecoded RequirementClear Text Reply
AEXRBattery Quantity4
CWWBBattery Recovery Time300.0
AYNHOperating Ambient Temp Range+0.0 TO 40.0 DEG CELSIUS
CWGNOutput PhaseTHREE SINGLE POWER OUTPUT
APTSOutput Frequency Rating47.0 HERTZ MINIMUM AND 53.0 HERTZ MAXIMUM SINGLE POWER OUTPUT
APPAOutput Voltage Rating230.0 AC VOLTS MINIMUM AND 400.0 AC VOLTS MAXIMUM SINGLE POWER OUTPUT
CWGSOutput Waveform And Current TypeSINUSOIDAL AC SINGLE POWER OUTPUT
BHQNRectification MethodFULL WAVE OPEN BRIDGE
APTQInput Frequency Rating47.0 HERTZ MINIMUM AND 70.0 HERTZ MAXIMUM SINGLE OPERATING POWER RQMT
ANPMInput PhaseTHREE SINGLE OPERATING POWER RQMT
APNXInput Voltage Rating400.0 AC VOLTS NOMINAL SINGLE OPERATING POWER RQMT
AMQYInstallation DesignFLOOR
ABKWOverall Height1499.0 MILLIMETERS MAXIMUM
ABHPOverall Length813.0 MILLIMETERS MAXIMUM
ABMKOverall Width559.0 MILLIMETERS MAXIMUM
CXCYPart Name Assigned By Controlling AgencyAPC SMART-UPS VT
FEATSpecial FeaturesBUILT-IN MAINT BYPASS; BUILT-IN STATIC BYPASS; MULTI-FUNCTION LCD STATUS AND CONTROL CONSOLE; AUDIBLE AND VISUAL ALARMS


Back to Top
Back to Top