6130-01-623-3348

POWER SUPPLY,UNINTERRUPTIBLE


6130-01-623-3348 (6130016233348, 016233348)
Part Number (1 listing): EP2000T
Summary

FSG 61 / FSC 6130

DEMIL: A

DEMIL INT: 1

HMIC: N

Date Created: 8 Nov 2013

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 6130-01-623-3348 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
EP2000T3 - Design Control Reference2 - Production ItemGE DIGITAL ENERGY  3B4L6      
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.


FLIS - SEG A - IDENTIFICATION | NSN 6130-01-623-3348 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
616130016233348A3990067374X1ANAA08 Nov 2013
Code Definitions

61

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electric Wire, and Power and Distribution Equipment

6130

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Converters, Electrical, Nonrotating

016233348

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 6130-01-623-3348

A39900

Federal Item Identification Guide (FIIG_4065)

67374

Item Naming Code (INC_4080)

8 Nov 2013

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

1

Type of Item Identification (TYP_II_4820)


Full Descriptive Item Identification

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

A

Electrostatic Discharge Code (ESD_EMI_CD_2043)


No known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity.

A

Precious Metals Indicator Code (PMIC_0802)


Item does not contain Precious Metal.

0

ADPE Identification Code (ADPEC_0801)


Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)


FLIS - SEG B - MOE RULE DATA | NSN 6130-01-623-3348 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
ZH011 Nov 2013
Code Definitions

FLIS - SEG C - REFERENCE NUMBER | NSN 6130-01-623-3348 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
323ZZEP2000T  3B4L6  
Code Definitions

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

3

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the technical documentation upon request.

ZZ

Reference Number Action Activity Code (RNAAC_2900)


USA


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 6130-01-623-3348 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
59708 Nov 2013
Code Definitions

5

Item Standardization Code (ISC_2650)


An item authorized for procurement that has not yet been subject to item standardization.

97

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


DLIS-LFF, Battle Creek, MI 49037-3084

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

8 Nov 2013

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 6130-01-623-3348 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
ZH
Code Definitions

ZH

Originating Activity Code (ORIG_ACTY_CD_4210)


Republic of Korea

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 6130-01-623-3348 Submit RFQ
MRCDecoded RequirementClear Text Reply
AJJYDocument Source3B4L6
CXMXBattery Power Supply Emergency Operating Time120.0
CWJFBattery LocationINTERNAL
AEXRBattery Quantity1
ADZCEnvironmental ProtectionGENERAL PURPOSE
ANRQFrequency Regulation Percent85.0 SINGLE POWER OUTPUT
CWGHOutput Current Rating2000.0 AC VOLT-AMPERE NOMINAL MULTIPLE POWER OUTPUTS W/IDENTICAL RATINGS
APTSOutput Frequency Rating50.0 HERTZ MINIMUM AND 60.0 HERTZ MAXIMUM MULTIPLE POWER OUTPUTS W/IDENTICAL RATINGS
CWGNOutput PhaseSINGLE MULTIPLE POWER OUTPUTS W/IDENTICAL RATINGS
BGQROutput Wattage Rating1400.0 WATTS NOMINAL MULTIPLE POWER OUTPUTS W/IDENTICAL RATINGS
APPAOutput Voltage Rating220.0 AC VOLTS NOMINAL AND 230.0 AC VOLTS NOMINAL AND 240.0 AC VOLTS NOMINAL MULTIPLE POWER OUTPUTS W/IDENTICAL RATINGS
APTQInput Frequency Rating56.0 HERTZ MINIMUM AND 64.0 HERTZ MAXIMUM SINGLE OPERATING POWER RQMT
APNXInput Voltage Rating110.0 AC VOLTS NOMINAL AND 30.0 AC VOLTS NOMINAL SINGLE OPERATING POWER RQMT
ANPMInput PhaseSINGLE SINGLE OPERATING POWER RQMT
ABKWOverall Height340.0 MILLIMETERS NOMINAL
ABHPOverall Length460.0 MILLIMETERS NOMINAL
ABMKOverall Width192.0 MILLIMETERS NOMINAL
CXCYPart Name Assigned By Controlling AgencyDIGITAL ENERGY EP SERIES UPS TOWER
CWKGVentilation Design TypeSINGLE FAN


Back to Top
Back to Top