6130-01-641-9933

POWER SUPPLY


6130-01-641-9933 (6130016419933, 016419933)
Part Number (1 listing): 6627A-700-750
Summary

FSG 61 / FSC 6130

DEMIL: A

DEMIL INT: 1

HMIC: N

Date Created: 10 Feb 2015

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 6130-01-641-9933 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
6627A-700-7503 - Design Control Reference2 - Production ItemAGILENT TECHNOLOGIES, INC.  1LQK8    CAGE 1LQK8  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.


FLIS - SEG A - IDENTIFICATION | NSN 6130-01-641-9933 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
616130016419933A3990000740X1ANA010 Feb 2015
Code Definitions

61

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electric Wire, and Power and Distribution Equipment

6130

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Converters, Electrical, Nonrotating

016419933

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 6130-01-641-9933

A39900

Federal Item Identification Guide (FIIG_4065)

00740

Item Naming Code (INC_4080)

10 Feb 2015

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

1

Type of Item Identification (TYP_II_4820)


Full Descriptive Item Identification

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

A

Precious Metals Indicator Code (PMIC_0802)


Item does not contain Precious Metal.

0

ADPE Identification Code (ADPEC_0801)


Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)


FLIS - SEG B - MOE RULE DATA | NSN 6130-01-641-9933 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
YB011 Feb 2015
Code Definitions

FLIS - SEG C - REFERENCE NUMBER | NSN 6130-01-641-9933 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
43219ZD6627A-700-750  1LQK8   CAGE/1LQK8
Code Definitions

4

Reference Number Format Code (RNFC_2920)


Number is totally in-the-clear (without modification) as originally configured by the manufacturer, design control activity, or supplier.

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

1

Document Availability Code (DAC_2640)


The reference number is represented by a drawing and the drawing was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the drawing upon request.

9Z

Reference Number Action Activity Code (RNAAC_2900)


DLIS-K, Battle Creek, MI 49037-3084

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.


FLIS - SEG G - FREIGHT DATA | NSN 6130-01-641-9933 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
Code Definitions

EA

Originating Activity Code (ORIG_ACTY_CD_4210)


Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 6130-01-641-9933 Submit RFQ
MRCDecoded RequirementClear Text Reply
CXCYPart Name Assigned By Controlling AgencyMULTIPLE OUTPUT LINEAR SYSTEM DC POWER SUPPLY
APTQInput Frequency Rating47.0 HERTZ MINIMUM AND 66.0 HERTZ MAXIMUM 1ST OPERATING POWER RQMT
APTQInput Frequency Rating47.0 HERTZ MINIMUM AND 66.0 HERTZ MAXIMUM 2ND OPERATING POWER RQMT
APTQInput Frequency Rating47.0 HERTZ MINIMUM AND 66.0 HERTZ MAXIMUM 3RD OPERATING POWER RQMT
APTQInput Frequency Rating47.0 HERTZ MINIMUM AND 66.0 HERTZ MAXIMUM 4TH OPERATING POWER RQMT
ANPMInput PhaseSINGLE 1ST OPERATING POWER RQMT
ANPMInput PhaseSINGLE 3RD OPERATING POWER RQMT
ANPMInput PhaseSINGLE 4TH OPERATING POWER RQMT
ANPMInput PhaseSINGLE 2ND OPERATING POWER RQMT
APNXInput Voltage Rating100.0 AC VOLTS MINIMUM AND 240.0 AC VOLTS MAXIMUM 1ST OPERATING POWER RQMT
APNXInput Voltage Rating100.0 AC VOLTS MINIMUM AND 240.0 AC VOLTS MAXIMUM 2ND OPERATING POWER RQMT
APNXInput Voltage Rating100.0 AC VOLTS MINIMUM AND 240.0 AC VOLTS MAXIMUM 3RD OPERATING POWER RQMT
APNXInput Voltage Rating100.0 AC VOLTS MINIMUM AND 240.0 AC VOLTS MAXIMUM 4TH OPERATING POWER RQMT
CWGZRipple Voltage At Full Load500.0 MICROVOLTS RMS 1ST POWER OUTPUT
CWGZRipple Voltage At Full Load500.0 MICROVOLTS RMS 2ND POWER OUTPUT
CWGZRipple Voltage At Full Load500.0 MICROVOLTS RMS 3RD POWER OUTPUT
CWGZRipple Voltage At Full Load500.0 MICROVOLTS RMS 4TH POWER OUTPUT
CWGHOutput Current Rating2.0 DC AMPERES MINIMUM AND 0.8 DC AMPERES MAXIMUM 1ST POWER OUTPUT
CWGHOutput Current Rating2.0 DC AMPERES MINIMUM AND 0.8 DC AMPERES MAXIMUM 2ND POWER OUTPUT
CWGHOutput Current Rating2.0 DC AMPERES MINIMUM AND 0.8 DC AMPERES MAXIMUM 3RD POWER OUTPUT
CWGHOutput Current Rating2.0 DC AMPERES MINIMUM AND 0.8 DC AMPERES MAXIMUM 4TH POWER OUTPUT
APTSOutput Frequency Rating47.0 HERTZ MINIMUM AND 66.0 HERTZ MAXIMUM 1ST POWER OUTPUT
APTSOutput Frequency Rating47.0 HERTZ MINIMUM AND 66.0 HERTZ MAXIMUM 2ND POWER OUTPUT
APTSOutput Frequency Rating47.0 HERTZ MINIMUM AND 66.0 HERTZ MAXIMUM 3RD POWER OUTPUT
APTSOutput Frequency Rating47.0 HERTZ MINIMUM AND 66.0 HERTZ MAXIMUM 4TH POWER OUTPUT
CWGNOutput PhaseSINGLE 2ND POWER OUTPUT
CWGNOutput PhaseSINGLE 3RD POWER OUTPUT
CWGNOutput PhaseSINGLE 4TH POWER OUTPUT
CWGNOutput PhaseSINGLE 1ST POWER OUTPUT
APPAOutput Voltage Rating20.0 DC VOLTS MINIMUM AND 50.0 DC VOLTS MAXIMUM 1ST POWER OUTPUT
APPAOutput Voltage Rating20.0 DC VOLTS MINIMUM AND 50.0 DC VOLTS MAXIMUM 2ND POWER OUTPUT
APPAOutput Voltage Rating20.0 DC VOLTS MINIMUM AND 50.0 DC VOLTS MAXIMUM 3RD POWER OUTPUT
APPAOutput Voltage Rating20.0 DC VOLTS MINIMUM AND 50.0 DC VOLTS MAXIMUM 4TH POWER OUTPUT
BGQROutput Wattage Rating40.0 WATTS NOMINAL 1ST POWER OUTPUT
BGQROutput Wattage Rating40.0 WATTS NOMINAL 2ND POWER OUTPUT
BGQROutput Wattage Rating40.0 WATTS NOMINAL 3RD POWER OUTPUT
ABKWOverall Height132.6 MILLIMETERS NOMINAL
ABHPOverall Length497.8 MILLIMETERS NOMINAL
ABMKOverall Width425.5 MILLIMETERS NOMINAL


Back to Top