6130-01-644-7696

POWER SUPPLY


6130-01-644-7696 (6130016447696, 016447696)
Part Numbers (3 listings): BADGERII | 340-08-104-01 | 340-08-104 |
Summary

FSG 61 / FSC 6130

DEMIL: Q

DEMIL INT: 3

HMIC: N

Date Created: 19 May 2015

MSDS: None

Hazmat: None

Export License Required:
Critical Munitions List Item or Sensitive Commerce Control List Item

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 6130-01-644-7696 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
BADGER II3 - Design Control Reference2 - Production ItemMISSION POWER SOLUTIONS, INC  1FWR8      
340-08-104-015 - Replaced / Discontinued2 - Production ItemJENKINS ENGINEERING DEFENCE SYSTEMS  Z2B33      
340-08-1045 - Replaced / Discontinued9 - No Longer UsedJENKINS ENGINEERING DEFENCE SYSTEMS  Z2B33      
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

5 - Replaced / Discontinued

Reference Number Category Code (DRN_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

9 - No Longer Used

Reference Number Variation Code (DRN_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.


FLIS - SEG A - IDENTIFICATION | NSN 6130-01-644-7696 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
616130016447696A3990000740X1QNAA019 May 2015
Code Definitions

61

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electric Wire, and Power and Distribution Equipment

6130

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Converters, Electrical, Nonrotating

016447696

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 6130-01-644-7696

A39900

Federal Item Identification Guide (FIIG_4065)

00740

Item Naming Code (INC_4080)

19 May 2015

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

1

Type of Item Identification (TYP_II_4820)


Full Descriptive Item Identification

Q

Demilitarization Code (DEMIL_CD_0167)


CCLI — Commerce Control List Item Demilitarization not required. CCLI are dual-use (military, commercial, and other strategic uses) items under the jurisdiction of the Bureau of Export Administration, U.S. Department of Commerce, through the Export Administration Regulations. The types of items under the Commerce Control List (CCL) are commodities (i.e., equipment, materials, electronics, propulsion systems, etc.), software, and technology. The CCL does not include those items exclusively controlled by another department or agency of the U.S. Government.

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

A

Electrostatic Discharge Code (ESD_EMI_CD_2043)


No known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity.

A

Precious Metals Indicator Code (PMIC_0802)


Item does not contain Precious Metal.

0

ADPE Identification Code (ADPEC_0801)


Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)


FLIS - SEG B - MOE RULE DATA | NSN 6130-01-644-7696 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
ZA011 May 2015
Code Definitions

FLIS - SEG C - REFERENCE NUMBER | NSN 6130-01-644-7696 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
43219ZDBADGER II  1FWR8  
452EZAA340-08-104-01  Z2B33  
4593ZAB340-08-104  Z2B33  
Code Definitions

4

Reference Number Format Code (RNFC_2920)


Number is totally in-the-clear (without modification) as originally configured by the manufacturer, design control activity, or supplier.

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

1

Document Availability Code (DAC_2640)


The reference number is represented by a drawing and the drawing was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the drawing upon request.

9Z

Reference Number Action Activity Code (RNAAC_2900)


DLIS-K, Battle Creek, MI 49037-3084

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.

5

Reference Number Category Code (RNCC_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

E

Document Availability Code (DAC_2640)


The reference number is represented by engineering data other than an engineering drawing. The data is available for unlimited use and will be furnished by the activity identified by the RNAAC upon request.

ZA

Reference Number Action Activity Code (RNAAC_2900)


Australia

A

Reference Number Status Code (RNSC_2923)


Manufacturer and reference number are authorized for procurement. Under this reference number items can be procured only from the manufacturer identified by the NCAGE. NOTE: This code may only be used for reference numbers originating from manufacturers' standards or catalogs or for copyrighted drawing numbers.

9

Reference Number Variation Code (RNVC_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.

3

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the technical documentation upon request.

B

Reference Number Status Code (RNSC_2923)


Manufacturer and/or reference number are not authorized for procurement. NOTE: This code may be used for obsolete or informative reference numbers only.


FLIS - SEG G - FREIGHT DATA | NSN 6130-01-644-7696 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
ZA
Code Definitions

ZA

Originating Activity Code (ORIG_ACTY_CD_4210)


Australia

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 6130-01-644-7696 Submit RFQ
MRCDecoded RequirementClear Text Reply
CBBLFeatures ProvidedEMI FILTER
CXCYPart Name Assigned By Controlling AgencyBADGER II
APTQInput Frequency Rating47.0 HERTZ MINIMUM AND 500.0 HERTZ MAXIMUM SINGLE OPERATING POWER RQMT
ANPMInput PhaseSINGLE SINGLE OPERATING POWER RQMT
APNXInput Voltage Rating85.0 AC VOLTS MINIMUM AND 254.0 AC VOLTS MAXIMUM SINGLE OPERATING POWER RQMT
CWGHOutput Current Rating40.0 AC AMPERES NOMINAL SINGLE POWER OUTPUT
APPAOutput Voltage Rating110.0 AC VOLTS MINIMUM AND 220.0 AC VOLTS MAXIMUM SINGLE POWER OUTPUT
APTSOutput Frequency Rating52.0 HERTZ MINIMUM AND 500.0 HERTZ MAXIMUM SINGLE POWER OUTPUT
CWGNOutput PhaseSINGLE SINGLE POWER OUTPUT
ABKWOverall Height2.55 INCHES NOMINAL
ABHPOverall Length13.75 INCHES NOMINAL
ABMKOverall Width7.0 INCHES NOMINAL
FEATSpecial FeaturesPOWER FACTOR CORRECTED AC-DC SWITCHER; UP TO 12 ISOLATED OUTPUTS; FAN COOLED; SOFT START FOR LIMITING INRUSH CURRENT; -20, -40, OR -55?C OPERATING TEMPERATURE; HEAVY-DUTY RUGGED ENCLOSURE DESIGNED FOR A HIGH SHOCK AND VIBRATION ENVIRONMENT


Back to Top