Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
CPCI-354-1203 | 3 - Design Control Reference | 2 - Production Item | CONDOR D C POWER SUPPLIES INC | 34337 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
61 | 6130 | 016475310 | A39900 | 00740 | X | 4 | 3 | A | N | A | 0 | 24 Aug 2015 |
Electric Wire, and Power and Distribution Equipment
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Partial Descriptive Item Identification (Type 1 Concept)
An approved item name and FIIG exist but the item involved is so unique in design that it cannot be fully described in accordance with the FIIG.
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.
Item does not contain Precious Metal.
Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
YB01 | 1 Aug 2015 |
RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
4 | 3 | 2 | 1 | 9Z | D | CPCI-354-1203 | 34337 | ![]() |
Number is totally in-the-clear (without modification) as originally configured by the manufacturer, design control activity, or supplier.
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
The reference number is represented by a drawing and the drawing was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the drawing upon request.
DLIS-K, Battle Creek, MI 49037-3084
Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No Variation. NMFC and UFCC Match.
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
CBBL | Features Provided | EMI FILTER AND OVER TEMPERATURE PROTECTION AND OVER VOLTAGE PROTECTOR AND REVERSE VOLTAGE PROTECTION AND ROHS DIRECTIVE COMPLIANCE AND REMOTE ERROR SENSING CAPABILITY |
CXCY | Part Name Assigned By Controlling Agency | SYSTEM POWER SUPPLY |
APTQ | Input Frequency Rating | 47.0 HERTZ MINIMUM AND 63.0 HERTZ MAXIMUM SINGLE OPERATING POWER RQMT |
CWGH | Output Current Rating | 4.0 AC AMPERES NOMINAL 4TH POWER OUTPUT |
CWGH | Output Current Rating | 40.0 AC AMPERES NOMINAL 2ND POWER OUTPUT |
CWGH | Output Current Rating | 50.0 AC AMPERES NOMINAL 1ST POWER OUTPUT |
CWGH | Output Current Rating | 12.0 AC AMPERES NOMINAL 3RD POWER OUTPUT |
APPA | Output Voltage Rating | -12.0 AC VOLTS NOMINAL 4TH POWER OUTPUT |
APPA | Output Voltage Rating | 3.3 AC VOLTS NOMINAL 2ND POWER OUTPUT |
APPA | Output Voltage Rating | 5.0 AC VOLTS NOMINAL 1ST POWER OUTPUT |
APPA | Output Voltage Rating | 12.0 AC VOLTS NOMINAL 3RD POWER OUTPUT |
BGQR | Output Wattage Rating | 350.0 WATTS MAXIMUM MULTIPLE POWER OUTPUTS W/IDENTICAL RATINGS |
ABKW | Overall Height | 40.34 MILLIMETERS NOMINAL |
ABHP | Overall Length | 261.9 MILLIMETERS NOMINAL |
ABMK | Overall Width | 165.2 MILLIMETERS NOMINAL |
FEAT | Special Features | EFFICIENCY: 70% TYPICAL; AC INPUT WITH PFC, QUAD OUTPUT, HOT SWAP; 38 PIN MODULAR; 350 W IN 6U X 8HP; RACKMOUNT; AC INPUT VOLTAGE: 90 TO 264 V |