6130-01-657-9603

POWER SUPPLY,UNINTERRUPTIBLE


6130-01-657-9603 (6130016579603, 016579603)
Part Number (1 listing): SY50K100F
Summary

FSG 61 / FSC 6130

DEMIL: A

DEMIL INT: 1

HMIC: N

Date Created: 7 Sep 2016

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 6130-01-657-9603 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
SY50K100F3 - Design Control Reference2 - Production ItemSCHNEIDER ELECTRIC IT CORPORATION  0MG77      
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.


FLIS - SEG A - IDENTIFICATION | NSN 6130-01-657-9603 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
616130016579603A3990067374X43ANAA07 Sep 2016
Code Definitions

61

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electric Wire, and Power and Distribution Equipment

6130

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Converters, Electrical, Nonrotating

016579603

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 6130-01-657-9603

A39900

Federal Item Identification Guide (FIIG_4065)

67374

Item Naming Code (INC_4080)

7 Sep 2016

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

4

Type of Item Identification (TYP_II_4820)


Partial Descriptive Item Identification (Type 1 Concept)

3

Reference / Partial Descriptive Method Reason Code (RPDMRC_4765)


An approved item name and FIIG exist but the item involved is so unique in design that it cannot be fully described in accordance with the FIIG.

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

A

Electrostatic Discharge Code (ESD_EMI_CD_2043)


No known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity.

A

Precious Metals Indicator Code (PMIC_0802)


Item does not contain Precious Metal.

0

ADPE Identification Code (ADPEC_0801)


Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)


FLIS - SEG B - MOE RULE DATA | NSN 6130-01-657-9603 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
ZC011 Sep 2016
Code Definitions

FLIS - SEG C - REFERENCE NUMBER | NSN 6130-01-657-9603 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
43249ZDSY50K100F  0MG77  
Code Definitions

4

Reference Number Format Code (RNFC_2920)


Number is totally in-the-clear (without modification) as originally configured by the manufacturer, design control activity, or supplier.

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

4

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the technical documentation.

9Z

Reference Number Action Activity Code (RNAAC_2900)


DLIS-K, Battle Creek, MI 49037-3084

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.


FLIS - SEG G - FREIGHT DATA | NSN 6130-01-657-9603 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
DF
Code Definitions

DF

Originating Activity Code (ORIG_ACTY_CD_4210)


U.S. Army Tank Automotive Command, Warren, MI 48090

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 6130-01-657-9603 Submit RFQ
MRCDecoded RequirementClear Text Reply
CWHYBattery Feature And TypeRECHARGEABLE LEAD ACID CELL
CWWBBattery Recovery Time2.0
AEXRBattery Quantity5
AKAEMaximum Operating Altitude Rating999.9 METERS
AYNHOperating Ambient Temp Range+0.0 TO 40.0 DEG CELSIUS
APPAOutput Voltage Rating100.0 AC KILOVOLTS MAXIMUM 3RD POWER OUTPUT
APPAOutput Voltage Rating120.0 AC VOLTS NOMINAL 1ST POWER OUTPUT
APPAOutput Voltage Rating208.0 AC VOLTS NOMINAL 2ND POWER OUTPUT
APPAOutput Voltage Rating208.0 AC VOLTS NOMINAL 4TH POWER OUTPUT
CXCYPart Name Assigned By Controlling AgencySYMMETRA PX 50KW SCALABLE TO 100KW, 208V W/STARTUP
CWHMInput Current Rating332.0 AC AMPERES MAXIMUM SINGLE OPERATING POWER RQMT
APTQInput Frequency Rating40.0 HERTZ MINIMUM AND 70.0 HERTZ MAXIMUM SINGLE OPERATING POWER RQMT
APNXInput Voltage Rating208.0 AC VOLTS NOMINAL SINGLE OPERATING POWER RQMT
ANPMInput PhaseTHREE SINGLE OPERATING POWER RQMT
APTSOutput Frequency Rating60.0 HERTZ NOMINAL MULTIPLE POWER OUTPUTS W/IDENTICAL RATINGS
CWGNOutput PhaseTHREE 4TH POWER OUTPUT
BGQROutput Wattage Rating100.0 KILOWATTS MAXIMUM MULTIPLE POWER OUTPUTS W/IDENTICAL RATINGS
ABKWOverall Height2011.0 MILLIMETERS NOMINAL
ABHPOverall Length1070.0 MILLIMETERS NOMINAL
ABMKOverall Width1200.0 MILLIMETERS NOMINAL


Back to Top