Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
2711727-1 | 3 - Design Control Reference | 2 - Production Item | RAYTHEON COMPANY | 96214 |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
61 | 6135 | 011773552 | T139-A | 60096 | X | M | 3 | B | P | A | 0 | 24 Apr 1984 |
Electric Wire, and Power and Distribution Equipment
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Partial Descriptive - Reference Item Identification (Type 1A Concept)
An approved item name and FIIG exist but the item involved is so unique in design that it cannot be fully described in accordance with the FIIG.
MLI (Non-Significant Military Equipment – Non-SME) — Demilitarization not required — Trade Security Controls (TSCs) required at disposition.
Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
Item does not contain Precious Metal.
Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
FUU5 | 2 | C | D | SU | 1 Apr 1991 |
Suitable for competitive acquisition for the first. time. Potential sources shall include dealers/distributors. If sources are limited to the prime contractor and a subcontractor, a competitive code shall not be assigned unless both sources are expected to compete independently for contracts for the part.
This part requires engineering source approval by the design control activity in order to maintain the quality of the part. An alternate source must qualify in accordance with the design control activity's procedures, as approved by the cognizant Government engineering activity. Valid AMCs: 1, 2, 3, 4 and 5.
Major End Items of Equipment: Items of such importance to the operations readiness of operating units that they are subject to continuing centralized individual item management and asset control throughout all command and support echelons.
Ogden Air Logistics Center, Hill AFB, UT 84056-5609
RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
3 | 2 | 2 | ME | 2711727-1 | 96214 |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
The reference number is represented by a drawing and the drawing was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the drawing.
Engineering Data Support Center, Hill AFB, UT 84056-5609
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
5 | 97 | 0 | 24 Apr 1984 |
An item authorized for procurement that has not yet been subject to item standardization.
DLIS-LFF, Battle Creek, MI 49037-3084
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
SU | 402 | F | 9 | A | 4 | M | M | 064300 | B | 05980 | EXPLOSIVES-AMMO-OR-CARTRIDGES-SUB2 |
Ogden Air Logistics Center, Hill AFB, UT 84056-5609
Fixed Ammunition without Explosive Projectiles and Like items (II-B)
Explosives, class C, UN class 1
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Explosives (any item that has an explosive characteristic that doesn't fall under Ammunition Code 3 including Inert Component Parts.)
Noncontrolled ammunitions excluded from categories I through IV above although reflected as pilferable on the shipment release document. Does not require protection other than that based on the class/degree and hazard/explosive. If none of those characteristics are present, protection will be the same as that provided other pilferable items.
85
No Variation. NMFC and UFCC Match.
Ogden Air Logistics Center, 6033 Elm Lane, Hill AFB, UT 84056-5619
DoD INTEGRATED MATERIEL-MANAGED, STOCKED, AND ISSUED. Issue, transfer, or shipment is not subject to specialized controls other than those imposed by the Integrated Materiel Manager/Service supply policy. 1. The item is centrally managed, stocked, and issued. 2. Requisitions must contain the fund citation required to acquire the item. Requisitions will be submitted in accordance with Integrated Materiel Manager(IMM)/Service requisitioning procedures.
Unclassified
1
AIR FORCE ERRC XB3: Stock Fund (Except Munitions); DLA: This item has been reviewed and a determination made that the item cannot or should not be restored to a serviceable condition from an unserviceable condition; NAVY: 1I cog not stocked print on demand flat forms
Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.
TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.
Department of the Air Force
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
AGAV | End Item Identification | PAVEWAY III LGB |
FEAT | Special Features | UO/L ENVELOPE LG 5.330 IN.PORM 0.250 IN.INSIDE DIA,3.500 IN.;TERMINALS MAX.OF 1.050 IN.FROM THE CENTER OF 3.500 IN.DIA.;LOAD CURRENT-17 VOLTS PORM 2.5 AMPERES PEAK-1.55 AMPERES AVERAGE FOR VARIOUS ELECTRONIC COMPONENTS AND GYRO MOTORS;PLUS 9 VOLTS OUTPUT,5.0 AMPERES FOR VARIOUS ELECTRONIC COMPONENTS;PLUS 28 VOLTS OUTPUT,6.5 AMPERES PEAK,3.85 AMPER AVERAGE FOR TORQUE MOTORS ANDSOLENOID VALVES;OPERATING LIFE BATERY SHALL MAINTAIN VOLTAGE OUTPUT WITHIN LIMITS OF LOAD CONDITIONS FOR A MINIMUM OF 90 SECONDS AFTER 0.5 SECOND INITIATION TIME;9 BRACKETS SPOTWELDED EQUALLED SPACED;TEMPERATURE INDICATOR WHEN BATTERY HAS BEEN EXPOSED TO TEMPERATURE IN EXCESS OF 260 DEGREES F.;IGNITER SHALL BE CONTINUOUS AND HAVE A RESISTANCE 1.0 PORM 0.2 OHMS |