Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
S | 3 - Design Control Reference | 1 - Incomplete Part Number | UNDERWRITERS LABORATORIES INC | 88193 | |
TIREX2C0NDUCT0RS10AWG | 3 - Design Control Reference | 2 - Production Item | TYCO ELECTRONICS INTEGRATED CABLE | 78310 | |
S2N010AWG259STRANDSN034 | 3 - Design Control Reference | 2 - Production Item | UNDERWRITERS LABORATORIES INC. | 81345 |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
61 | 6145 | 001606192 | A077A0 | 00232 | X | 1 | A | N | U | 1 Jan 1963 |
Electric Wire, and Power and Distribution Equipment
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Full Descriptive Item Identification
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.
Precious Metal Content is unknown.
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ZH01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZU01 | 1 Apr 1991 |
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
3 | KZ | 1 | 1 | KZ | 0 | 30 Dec 1966 | 6145005481076 | 30 Dec 1966 |
An item which, as a result of a formal item reduction study, is accepted as not authorized for procurement.
Defense Supply Center Philadelphia, Philadelphia, PA 19101
Represents an item for which a U.S. activity proposed cancelled-invalid or cancelled-use action or that the NIIN Status Code be changed to 9, and one or more NATO/FC did not concur in the proposal. See volume 4, chapter 4.9.Item is restricted to North Atlantic Treaty Organization/foreign country (NATO/FC) use only.Represents an item for which a U.S. activity proposed cancelled-invalid or cancelled-use action or that the NIIN Status Code be changed to 9, and one or more NATO/FC did not concur in the proposal. Item is restricted to North Atlantic Treaty Organization/foreign country (NATO/FC) use only.
An item authorized for procurement as a result of a formal item reduction study and accepted as a replacement for one or more items not authorized for procurement. In addition, in generic relationships, a code 1 item is related to a code 2 item.
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
S | 743 | Z | 9 | A | H | Z | W | 030310 | Z | 15080 | CABLE-OR-WIRE |
60
Electrical Cable
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
No special handling required.
Variable Rating
No Variation. NMFC and UFCC Match.
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
AMQN | Conductor Quantity | 2 |
CXCW | Conductor Form | STRANDED ALL CONDUCTORS |
MATT | Material | COPPER CORE CONDUCTOR ALL CONDUCTORS |
MATT | Material | RUBBER NATURAL 1ST POSITION PRIMARY INSULATION ALL CONDUCTORS |
MATT | Material | COTTON 1ST POSITION BRAID, NON-METALLIC CABLE |
MDCL | Material Document And Classification | MIL-I-3930,TYPE IS MIL SPEC SINGLE MATERIAL RESPONSE 1ST POSITION PRIMARY INSULATION ALL CONDUCTORS |
SFTT | Surface Treatment | TIN CORE CONDUCTOR ALL CONDUCTORS |
CXDC | Round Conductor Size | 10 AWG ALL CONDUCTORS |
BLNZ | Strand Quantity Per Conductor | 259 ALL CONDUCTORS |
CXDG | Strand Awg Size Per Conductor | 34 ALL CONDUCTORS |
HUES | Color | BLACK 1ST POSITION COVER FIRST CONDUCTOR |
HUES | Color | WHITE 2ND POSITION COVER SECOND CONDUCTOR |
CXFK | Voltage Rating | 600.0 AC MAXIMUM RATED WORKING VOLTAGE ALL CONDUCTORS |
AAGR | Cross-Sectional Shape Style | ROUND |
ADVL | Cross Section Outside Diameter | 0.640 INCHES NOMINAL |