6145-00-191-3618

CABLE,POWER,ELECTRICAL


6145-00-191-3618 (6145001913618, 001913618)
Part Number : None
Summary

FSG 61 / FSC 6145

DEMIL: A

DEMIL INT:

HMIC: N

Date Created: 1 Jan 1963

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 6145-00-191-3618 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
Code Definitions

FLIS - SEG A - IDENTIFICATION | NSN 6145-00-191-3618 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
616145001913618A077A000232X1ANU1 Jan 1963
Code Definitions

61

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electric Wire, and Power and Distribution Equipment

6145

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Wire and Cable, Electrical

001913618

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 6145-00-191-3618

A077A0

Federal Item Identification Guide (FIIG_4065)

00232

Item Naming Code (INC_4080)

1 Jan 1963

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

1

Type of Item Identification (TYP_II_4820)


Full Descriptive Item Identification

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

U

Precious Metals Indicator Code (PMIC_0802)


Precious Metal Content is unknown.


FLIS - SEG B - MOE RULE DATA | NSN 6145-00-191-3618 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
G77000C1 Apr 1991
ZW011 Nov 1998
Code Definitions

0

Acquisition Method Code (AMC_2871)


Not Established

C

Acquisition Advice Code (AAC_2507)


SERVICE/AGENCY-MANAGED (Service/Agency use only.) Issue, transfer, or shipment is not subject to specialized controls other than those imposed by individual Services supply policy. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with Service requisitioning procedures.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 6145-00-191-3618 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
2KZ015 Dec 1974
Code Definitions

2

Item Standardization Code (ISC_2650)


An item authorized for procurement which has been included in an item reduction study and which initially does not replace an item not authorized for procurement. In addition, in generic relationships, a code 2 item is related to a code 1 item.

KZ

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


Defense Supply Center Philadelphia, Philadelphia, PA 19101

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

15 Dec 1974

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 6145-00-191-3618 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
Code Definitions

XX

Originating Activity Code (ORIG_ACTY_CD_4210)


Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG H - MANAGEMENT DATA | NSN 6145-00-191-3618 Submit RFQ
Unit PriceMOESOSAACCIICQUPReparabilityUISLC
DNS9IDUUFT0
Code Definitions

S9I

Source of Supply (SOS_CD_3690) or Source of Supply Modifier (SOSM_CD_2948)


DLA Troop Support, Philadelphia, PA 19111 ** No longer valid for input **

D

Acquisition Advice Code (AAC_2507)


DoD INTEGRATED MATERIEL-MANAGED, STOCKED, AND ISSUED. Issue, transfer, or shipment is not subject to specialized controls other than those imposed by the Integrated Materiel Manager/Service supply policy. 1. The item is centrally managed, stocked, and issued. 2. Requisitions must contain the fund citation required to acquire the item. Requisitions will be submitted in accordance with Integrated Materiel Manager(IMM)/Service requisitioning procedures.

U

Controlled Item Inventory Code (CIIC_2863)


Unclassified

U

Quantity Unit Pack (QUP_6106)


250

FT

Unit of Issue (UI_3050)


Foot - Unit of linear measurement, sometimes expressed as “linear foot”.

0

Shelf Life Code (SLC_2943)


TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.

DN

Service / Agency Code (MOE_CD_2833)


Department of the Navy


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 6145-00-191-3618 Submit RFQ
MRCDecoded RequirementClear Text Reply
CXCWConductor FormSTRANDED ALL CONDUCTORS
CXDQConductor Arrangement And Quantity2 SINGLES
AAGRCross-Sectional Shape StyleROUND
AMQNConductor Quantity2
MATTMaterialCOPPER CORE CONDUCTOR ALL CONDUCTORS
MATTMaterialCOTTON 5TH POSITION BRAID, NON-METALLIC CABLE
MATTMaterialRUBBER NATURAL OR RUBBER SYNTHETIC 2ND POSITION PRIMARY INSULATION ALL CONDUCTORS
MATTMaterialRUBBER NATURAL OR RUBBER SYNTHETIC 4TH POSITION JACKET CABLE
CXDCRound Conductor Size14 AWG ALL CONDUCTORS
FEATSpecial FeaturesBRAID FIBROUS ALL CONDUCTORS,COVERING CHARACTERISTICS; BASIC BODY COLOR PER CONDUCTOR:BLACK FIRST CONDUCTOR,WHITE SECOND CONDUCTOR; LARGEST CROSS SECTION 0.475 IN.
CXFKVoltage Rating600.0 AC MAXIMUM RATED WORKING VOLTAGE ALL CONDUCTORS
CXDGStrand Awg Size Per Conductor26 1ST CONDUCTOR
CXDGStrand Awg Size Per Conductor36 2ND CONDUCTOR
BLNZStrand Quantity Per Conductor17 1ST CONDUCTOR
BLNZStrand Quantity Per Conductor164 2ND CONDUCTOR
SFTTSurface TreatmentTIN 1ST POSITION CONDUCTOR ALL CONDUCTORS


Back to Top