Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
MPD1507 | 3 - Design Control Reference | 1 - Incomplete Part Number | U S ARMY AVIATION AND MISSILE | 18876 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
61 | 6145 | 002259552 | A077A0 | 16488 | X | 1 | A | N | U | 1 Jan 1963 |
Electric Wire, and Power and Distribution Equipment
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Full Descriptive Item Identification
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.
Precious Metal Content is unknown.
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ZH01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZW01 | 1 Nov 2005 | |||||||||||||||||||||||||||||
YB01 | 1 Oct 2008 |
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
6 | KZ | 0 | 11 Jun 1974 |
An item authorized for procurement that is in a specific Federal Supply Class (FSC) or item name grouping consisting primarily of items which are one-of-a-kind; therefore, little or no potential exists for elimination of items through formal item reduction studies.
Defense Supply Center Philadelphia, Philadelphia, PA 19101
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
743 | Z | 9 | A | H | Z | W | 030310 | Z | 15080 | CABLE-OR-WIRE |
Electrical Cable
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
No special handling required.
Variable Rating
No Variation. NMFC and UFCC Match.
Defense Logistics Agency, Enterprise Business Systems
TERMINAL ITEM (NON-STOCKED ITEMS) Future procurement is not authorized. No wholesale stock is available for issue. 1. Requisitions will not be processed to the wholesale manager. 2. Internal Service/agency requisitioning may be continued in accordance with the Service/agency requisitioning policies.
Unclassified
500
Foot - Unit of linear measurement, sometimes expressed as “linear foot”.
TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.
Defense Logistics Agency
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
HUES | Color | WHITE 1ST POSITION COVER ALL CONDUCTORS |
CXCW | Conductor Form | STRANDED ALL CONDUCTORS |
AAGR | Cross-Sectional Shape Style | TWIST |
ADVN | Cross-Sectional Height | 0.054 INCHES NOMINAL |
ADWH | Cross-Sectional Width | 0.108 INCHES NOMINAL |
AMQN | Conductor Quantity | 2 |
MATT | Material | COPPER 1ST POSITION SHIELD BRAID, METALLIC CABLE |
MATT | Material | COPPER CORE CONDUCTOR ALL CONDUCTORS |
MATT | Material | PLASTIC POLYTETRAFLUOROETHYLENE 1ST POSITION PRIMARY INSULATION ALL CONDUCTORS |
MATT | Material | PLASTIC POLYTETRAFLUOROETHYLENE 2ND POSITION JACKET CABLE |
CXDC | Round Conductor Size | 22 AWG ALL CONDUCTORS |
CXFK | Voltage Rating | 600.0 MAXIMUM ROOT MEAN SQUARE (RMS) OPERATING VOLTAGE ALL CONDUCTORS |
CXDG | Strand Awg Size Per Conductor | 34 ALL CONDUCTORS |
BLNZ | Strand Quantity Per Conductor | 19 ALL CONDUCTORS |
SFTT | Surface Treatment | TIN CORE CONDUCTOR ALL CONDUCTORS |
ABJH | Temp Rating | -40.0 DEG CELSIUS AND 80.0 DEG CELSIUS |
ASGF | Tracer Color | BLACK FIRST TRACER FIRST CONDUCTOR |
ASGF | Tracer Color | BLACK FIRST TRACER SECOND CONDUCTOR |
ASGF | Tracer Color | BROWN SECOND TRACER FIRST CONDUCTOR |
ASGF | Tracer Color | ORANGE SECOND TRACER SECOND CONDUCTOR |