6145-00-393-4075

CABLE,POWER,ELECTRICAL


6145-00-393-4075 (6145003934075, 003934075)
Part Numbers (5 listings): 8860 | CIT4147 | 1065 | 12377 | 9620 |
Summary

FSG 61 / FSC 6145

DEMIL: A

DEMIL INT:

HMIC: N

Date Created: 5 Apr 1974

Unit Weight: 75.0 lbs

Unit Size: None

Unit Pack Cube: 2.439 cu ft

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 6145-00-393-4075 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
88603 - Design Control Reference2 - Production ItemJANOR WIRE & CABLE CORP  3N861      
CIT41473 - Design Control Reference2 - Production ItemCABLECO INC  3S767      
10655 - Replaced / Discontinued2 - Production ItemALPHA WIRE CORPORATION  92194    CAGE 92194  
123775 - Replaced / Discontinued2 - Production ItemBERKSHIRE ELECTRIC CABLE CO  97324      
96205 - Replaced / Discontinued2 - Production ItemBELDEN WIRE & CABLE COMPANY LLC  16428      
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

5 - Replaced / Discontinued

Reference Number Category Code (DRN_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.


FLIS - SEG A - IDENTIFICATION | NSN 6145-00-393-4075 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
616145003934075A077A000232X1ANA05 Apr 1974
Code Definitions

61

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electric Wire, and Power and Distribution Equipment

6145

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Wire and Cable, Electrical

003934075

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 6145-00-393-4075

A077A0

Federal Item Identification Guide (FIIG_4065)

00232

Item Naming Code (INC_4080)

5 Apr 1974

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

1

Type of Item Identification (TYP_II_4820)


Full Descriptive Item Identification

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

A

Precious Metals Indicator Code (PMIC_0802)


Item does not contain Precious Metal.

0

ADPE Identification Code (ADPEC_0801)


Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)


FLIS - SEG B - MOE RULE DATA | NSN 6145-00-393-4075 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
FXGXFXTX1ZZSX1 Nov 2005
N9BN1ZZGHHD1 Nov 2005
Code Definitions

1

Acquisition Method Code (AMC_2871)


Suitable for competitive acquisition. Potential sources shall include dealers/distributors. If sources are limited to the prime contractor and a subcontractor, a competitive code shall not be assigned unless both sources are expected to compete independently for contracts for the part.

Z

Acquisition Method Suffix Code (AMSC_2876)


This part is a commercial/non-developmental/off-the-shelf-item. Valid AMCs: 1, 2, 3, 4 and 5.

Z

Item Management Code (IMC_2744)


Integrated Management: Relinquishment of Service management of an item in designated commodity oriented Federal Supply Classes to the IMM (FSC manager) for management.

SX

Item Management Coding Activity (IMC_ACTY_2748)


Oklahoma City Air Logistics Center, Tinker AFB, OK 73145-3043

GH

Item Management Coding Activity (IMC_ACTY_2748)


Naval Inventory Control Point, Mechanicsburg, PA 17055-0788

HDCollaborators

Supplementary Collaborators (SUPPLM_COLLBR_2533)


Naval Inventory Control Point, Mechanicsburg, PA 17055-0788


FLIS - SEG C - REFERENCE NUMBER | NSN 6145-00-393-4075 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
325KZ8860  3N861  
321ZZCIT4147  3S767  
3524SBD1065  92194   CAGE/92194
52EKZ12377  97324  
52EKZ9620  16428  
Code Definitions

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

5

Document Availability Code (DAC_2640)


The reference number is represented by a drawing, but the drawing was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.

KZ

Reference Number Action Activity Code (RNAAC_2900)


Defense Supply Center Philadelphia, Philadelphia, PA 19101

1

Document Availability Code (DAC_2640)


The reference number is represented by a drawing and the drawing was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the drawing upon request.

ZZ

Reference Number Action Activity Code (RNAAC_2900)


USA

3

Reference Number Format Code (RNFC_2920)


Number format is unknown. (Coded RNFC 3 by the Defense Logistics Information Service upon implementation of FLIS.)

5

Reference Number Category Code (RNCC_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

4

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the technical documentation.

SB

Reference Number Action Activity Code (RNAAC_2900)


645 MSSQ/MSIAPCS, Wright-Patterson AFB, OH 45433-5603

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.

E

Document Availability Code (DAC_2640)


The reference number is represented by engineering data other than an engineering drawing. The data is available for unlimited use and will be furnished by the activity identified by the RNAAC upon request.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 6145-00-393-4075 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
6KZ013 Feb 1974
Code Definitions

6

Item Standardization Code (ISC_2650)


An item authorized for procurement that is in a specific Federal Supply Class (FSC) or item name grouping consisting primarily of items which are one-of-a-kind; therefore, little or no potential exists for elimination of items through formal item reduction studies.

KZ

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


Defense Supply Center Philadelphia, Philadelphia, PA 19101

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

13 Feb 1974

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 6145-00-393-4075 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
KZ743Z9AHZW030310Z15080CABLE-OR-WIRE
Code Definitions

KZ

Originating Activity Code (ORIG_ACTY_CD_4210)


Defense Supply Center Philadelphia, Philadelphia, PA 19101

743

Water Commodity Code (WRT_CMDTY_CD_9275)


Electrical Cable

Z

Type Cargo Code (TYPE_CGO_CD_9260)


No special type of cargo code applicable

9

Special Handling Code (SP_HDLG_CD_9240)


No special handling required

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

H

Air Commodity Code (AIR_CMTY_HDLG_9215)


Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.

Z

Air Special Handling Code (AIR_CMTY_HDLG_9215)


No special handling required.

W

Less Than Truckload (CLAS_RTNG_CD_2770)


Variable Rating

030310

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

Z

NMFC Sub Item Number (SUB_ITM_NBR_0861)

15080

Uniform Freight Classification (UFC_CD_MODF_3040)

CABLE-OR-WIRE

Freight Description (FRT_DESC_4020)

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG H - MANAGEMENT DATA | NSN 6145-00-393-4075 Submit RFQ
Unit PriceMOESOSAACCIICQUPReparabilityUISLC
DFSMSJU1NSL0
DNSMSJU1SL0
DSSMSJU1NSL0
Code Definitions

SMS

Source of Supply (SOS_CD_3690) or Source of Supply Modifier (SOSM_CD_2948)


Defense Logistics Agency, Enterprise Business Systems

J

Acquisition Advice Code (AAC_2507)


NOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition.

U

Controlled Item Inventory Code (CIIC_2863)


Unclassified

1

Quantity Unit Pack (QUP_6106)


1

N

Reparability Code (REP_CD_DLA_2934 / REP_CD_CG_0709 / ERRC_CD_AF_2655 / RECOV_CD_MC_2891 / RECOV_CD_AR_2892 / MAT_CTL_NVY_2832)


AIR FORCE ERRC XB3: Stock Fund (Except Munitions); DLA: This item has been reviewed and a determination made that the item cannot or should not be restored to a serviceable condition from an unserviceable condition; NAVY: 1I cog not stocked print on demand flat forms

SL

Unit of Issue (UI_3050)


Spool - A cylindrical form with an edge or rim at each end and an axial hole for a pin or spindle on which a flexible material such as thread or wire is wound. *Requires a quantitative expression

0

Shelf Life Code (SLC_2943)


TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.

DF

Service / Agency Code (MOE_CD_2833)


Department of the Air Force

DN

Service / Agency Code (MOE_CD_2833)


Department of the Navy

DS

Service / Agency Code (MOE_CD_2833)


Defense Logistics Agency


FLIS - SEG W - PACKAGING DATA | NSN 6145-00-393-4075 Submit RFQ
SourcePICA / SICAPackaging CategoryStoragePreservationClean/DryINT QtyUnit WeightUnit SizeUnit Pack CubeItem WeightItem Dims
PPZZ00075.0 lbs2.439 cu ft
Preservation MaterialWrapping MaterialCushioning / DunnageCushioning ThicknessUnit ContainerIntermediate ContainerUnit Container LevelSpecial MarkingLevel A PackingLevel B PackingMinimal PackingOptional Procedure
X00QQ6M
Code Definitions

P

Packaging Data Source Code (PK_DTA_SRC_CD_5148)


Primary Inventory Control Activity (PICA)

P

Primary / Secondary Inventory Control Code (PICA_SICA_IND_5099)


Primary Inventory Control Activity (PICA)

ZZ

Method of Preservation Code (MTHD_PRSRV_CD_5160)


See J.4.1.b

000

Intermediate Container Quantity (INTMD_CTN_QTY_5152)

75.0 lbs

Unit Pack Weight (UP_WT_5153)

2.439 cu ft

Unit Pack Cube (UP_CU_5155)

X

Thickness of Cushioning or Dunnage Code (THK_CUSH_DUN_5165)


As required to protect the item or elements of the package

00

Intermediate Container Code (INTMD_CTNR_CD_5167)


No requirement.

Q

Packing Requirement Code - For Level A (Maximum) Packing (LVL_A_PKG_CD_5170)


Packing shall be accomplished in accordance with table C.II for the packing level specified. Closure sealing and reinforcement shall be in accordance with applicable specification for shipping container.

Q

Packing Requirement Code - For Level B (Intermediate) Packing (LVL_B_PKG_CD_5171)


Packing shall be accomplished in accordance with table C-II for the packing level specified. Closure sealing and reinforcement shall be in accordance with the appropriate shipping container specification.

6

Packing Requirement Code - For Minimal Packing (MINM_PK_RQ_CD_5172)


Packing shall be accomplished to meet the performance test requirements of ASTMD4169, Distribution Cycle 18, Assurance Level 3.

M

Optional Procedure Indicator Code (OPTNL_PRO_IND_5173)


All packaging data is mandatory for compliance and no substitutions are permitted. Fast packs should be included in this category.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 6145-00-393-4075 Submit RFQ
MRCDecoded RequirementClear Text Reply
HUESColorBLACK 1ST POSITION COVER FIRST CONDUCTOR
HUESColorRED 3RD POSITION COVER THIRD CONDUCTOR
HUESColorWHITE 2ND POSITION COVER SECOND CONDUCTOR
HUESColorGRAY 1ST POSITION JACKET CABLE
HUESColorGREEN 4TH POSITION COVER FOURTH CONDUCTOR
HUESColorORANGE 5TH POSITION COVER FIFTH CONDUCTOR
CXDQConductor Arrangement And Quantity5 SINGLES
CXCWConductor FormSTRANDED ALL CONDUCTORS
ADVLCross Section Outside Diameter0.440 INCHES NOMINAL
AAGRCross-Sectional Shape StyleROUND
AMQNConductor Quantity5
MATTMaterialPLASTIC POLYVINYL CHLORIDE 1ST POSITION PRIMARY INSULATION ALL CONDUCTORS
MATTMaterialPLASTIC POLYVINYL CHLORIDE 2ND POSITION JACKET CABLE
MATTMaterialCOPPER 1ST POSITION TAPE CABLE
MATTMaterialCOPPER CORE CONDUCTOR ALL CONDUCTORS
CXDCRound Conductor Size16 AWG ALL CONDUCTORS
CXFKVoltage Rating600.0 MAXIMUM ROOT MEAN SQUARE (RMS) OPERATING VOLTAGE ALL CONDUCTORS
CXDGStrand Awg Size Per Conductor29 ALL CONDUCTORS
BLNZStrand Quantity Per Conductor19 ALL CONDUCTORS
SFTTSurface TreatmentTIN CORE CONDUCTOR ALL CONDUCTORS
ABJHTemp Rating-20.0 DEG CELSIUS AND 80.0 DEG CELSIUS


Back to Top
Back to Top