6145-00-455-2808

WIRE,ELECTRICAL


6145-00-455-2808 (6145004552808, 004552808)
Part Number (1 listing): SM1501E30-908
Summary

FSG 61 / FSC 6145

DEMIL: A

DEMIL INT:

HMIC: N

Date Created: 23 Apr 1969

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 6145-00-455-2808 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
SM1501E30-9083 - Design Control Reference2 - Production ItemGE AVIATION SYSTEMS LLC  35351    CAGE 35351  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.


FLIS - SEG A - IDENTIFICATION | NSN 6145-00-455-2808 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
616145004552808A077A000798X1ANS23 Apr 1969
Code Definitions

61

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electric Wire, and Power and Distribution Equipment

6145

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Wire and Cable, Electrical

004552808

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 6145-00-455-2808

A077A0

Federal Item Identification Guide (FIIG_4065)

00798

Item Naming Code (INC_4080)

23 Apr 1969

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

1

Type of Item Identification (TYP_II_4820)


Full Descriptive Item Identification

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

S

Precious Metals Indicator Code (PMIC_0802)


Item contains silver.


FLIS - SEG B - MOE RULE DATA | NSN 6145-00-455-2808 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
YJ011 Apr 1991
ZE011 Apr 1991
ZG011 Aug 2011
Code Definitions

FLIS - SEG C - REFERENCE NUMBER | NSN 6145-00-455-2808 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
3324TADSM1501E30-908  35351   CAGE/35351
Code Definitions

3

Reference Number Format Code (RNFC_2920)


Number format is unknown. (Coded RNFC 3 by the Defense Logistics Information Service upon implementation of FLIS.)

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

4

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the technical documentation.

TA

Reference Number Action Activity Code (RNAAC_2900)


Sacramento Air Logistics Center, McClellan AFB, CA 95652-5609

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 6145-00-455-2808 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
6KZ015 Feb 1973
Code Definitions

6

Item Standardization Code (ISC_2650)


An item authorized for procurement that is in a specific Federal Supply Class (FSC) or item name grouping consisting primarily of items which are one-of-a-kind; therefore, little or no potential exists for elimination of items through formal item reduction studies.

KZ

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


Defense Supply Center Philadelphia, Philadelphia, PA 19101

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

15 Feb 1973

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 6145-00-455-2808 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
KZ658Z9AHZW030310Z15080CABLE-OR-WIRE
Code Definitions

KZ

Originating Activity Code (ORIG_ACTY_CD_4210)


Defense Supply Center Philadelphia, Philadelphia, PA 19101

658

Water Commodity Code (WRT_CMDTY_CD_9275)


Electical Appliances, Small

Z

Type Cargo Code (TYPE_CGO_CD_9260)


No special type of cargo code applicable

9

Special Handling Code (SP_HDLG_CD_9240)


No special handling required

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

H

Air Commodity Code (AIR_CMTY_HDLG_9215)


Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.

Z

Air Special Handling Code (AIR_CMTY_HDLG_9215)


No special handling required.

W

Less Than Truckload (CLAS_RTNG_CD_2770)


Variable Rating

030310

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

Z

NMFC Sub Item Number (SUB_ITM_NBR_0861)

15080

Uniform Freight Classification (UFC_CD_MODF_3040)

CABLE-OR-WIRE

Freight Description (FRT_DESC_4020)

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 6145-00-455-2808 Submit RFQ
MRCDecoded RequirementClear Text Reply
CXCWConductor FormSTRANDED SINGLE CONDUCTOR
MATTMaterialSTEEL CORE CONDUCTOR SINGLE CONDUCTOR
MATTMaterialCOPPER 1ST POSITION CONDUCTOR SINGLE CONDUCTOR
MATTMaterialPLASTIC POLYTETRAFLUOROETHYLENE 1ST POSITION PRIMARY INSULATION SINGLE CONDUCTOR
SFTTSurface TreatmentSILVER CORE CONDUCTOR SINGLE CONDUCTOR
CXDCRound Conductor Size30 AWG SINGLE CONDUCTOR
BLNZStrand Quantity Per Conductor7 SINGLE CONDUCTOR
CXDGStrand Awg Size Per Conductor38 SINGLE CONDUCTOR
HUESColorWHITE 1ST POSITION COVER SINGLE CONDUCTOR
ASGFTracer ColorBLACK FIRST TRACER SINGLE CONDUCTOR
ASGFTracer ColorGRAY SECOND TRACER SINGLE CONDUCTOR
CXFKVoltage Rating300.0 AC MAXIMUM RATED WORKING VOLTAGE SINGLE CONDUCTOR
AAGRCross-Sectional Shape StyleROUND
ADVLCross Section Outside Diameter0.028 INCHES NOMINAL
FEATSpecial FeaturesCOPPER STRANDS AROUND A STEEL REINFORCING STRAND


Back to Top