6145-01-354-2603

CABLE,POWER,ELECTRICAL


6145-01-354-2603 (6145013542603, 013542603)
Part Number (1 listing): 0-79045-846
Summary

FSG 61 / FSC 6145

DEMIL: A

DEMIL INT:

HMIC: N

Date Created: 26 Feb 1992

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 6145-01-354-2603 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
0-79045-8463 - Design Control Reference2 - Production ItemRAYTHEON COMPANY  15090    CAGE 15090  
0-79045-8465 - Replaced / Discontinued9 - No Longer UsedHUGHES MISSILE SYSTEMS CO  14170    CAGE 14170  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

5 - Replaced / Discontinued

Reference Number Category Code (DRN_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

9 - No Longer Used

Reference Number Variation Code (DRN_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.


FLIS - SEG A - IDENTIFICATION | NSN 6145-01-354-2603 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
616145013542603A077A000232X1ANA026 Feb 1992
Code Definitions

61

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electric Wire, and Power and Distribution Equipment

6145

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Wire and Cable, Electrical

013542603

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 6145-01-354-2603

A077A0

Federal Item Identification Guide (FIIG_4065)

00232

Item Naming Code (INC_4080)

26 Feb 1992

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

1

Type of Item Identification (TYP_II_4820)


Full Descriptive Item Identification

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

A

Precious Metals Indicator Code (PMIC_0802)


Item does not contain Precious Metal.

0

ADPE Identification Code (ADPEC_0801)


Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)


FLIS - SEG B - MOE RULE DATA | NSN 6145-01-354-2603 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
FXGXFXTX3DZSX1 Nov 2005
Code Definitions

3

Acquisition Method Code (AMC_2871)


Acquire directly from the actual manufacturer, whether or not the prime contractor is the actual manufacturer.

D

Acquisition Method Suffix Code (AMSC_2876)


The data needed to produce this item from additional sources is not physically available. Valid AMCs: 3, 4 and 5.

Z

Item Management Code (IMC_2744)


Integrated Management: Relinquishment of Service management of an item in designated commodity oriented Federal Supply Classes to the IMM (FSC manager) for management.

SX

Item Management Coding Activity (IMC_ACTY_2748)


Oklahoma City Air Logistics Center, Tinker AFB, OK 73145-3043


FLIS - SEG C - REFERENCE NUMBER | NSN 6145-01-354-2603 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
325ZZ0-79045-846  15090   CAGE/15090
59EKZ0-79045-846  14170   CAGE/14170
Code Definitions

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

5

Document Availability Code (DAC_2640)


The reference number is represented by a drawing, but the drawing was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.

ZZ

Reference Number Action Activity Code (RNAAC_2900)


USA

5

Reference Number Category Code (RNCC_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

9

Reference Number Variation Code (RNVC_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.

E

Document Availability Code (DAC_2640)


The reference number is represented by engineering data other than an engineering drawing. The data is available for unlimited use and will be furnished by the activity identified by the RNAAC upon request.

KZ

Reference Number Action Activity Code (RNAAC_2900)


Defense Supply Center Philadelphia, Philadelphia, PA 19101


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 6145-01-354-2603 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
597026 Feb 1992
Code Definitions

5

Item Standardization Code (ISC_2650)


An item authorized for procurement that has not yet been subject to item standardization.

97

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


DLIS-LFF, Battle Creek, MI 49037-3084

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

26 Feb 1992

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 6145-01-354-2603 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
KH743Z9AHZW030310Z15080CABLE-OR-WIRE
Code Definitions

KH

Originating Activity Code (ORIG_ACTY_CD_4210)


Defense Industrial Supply Center, Philadelphia, PA 19111

743

Water Commodity Code (WRT_CMDTY_CD_9275)


Electrical Cable

Z

Type Cargo Code (TYPE_CGO_CD_9260)


No special type of cargo code applicable

9

Special Handling Code (SP_HDLG_CD_9240)


No special handling required

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

H

Air Commodity Code (AIR_CMTY_HDLG_9215)


Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.

Z

Air Special Handling Code (AIR_CMTY_HDLG_9215)


No special handling required.

W

Less Than Truckload (CLAS_RTNG_CD_2770)


Variable Rating

030310

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

Z

NMFC Sub Item Number (SUB_ITM_NBR_0861)

15080

Uniform Freight Classification (UFC_CD_MODF_3040)

CABLE-OR-WIRE

Freight Description (FRT_DESC_4020)

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG H - MANAGEMENT DATA | NSN 6145-01-354-2603 Submit RFQ
Unit PriceMOESOSAACCIICQUPReparabilityUISLC
DFSMSJU1NFT0
DSSMSJU1NFT0
Code Definitions

SMS

Source of Supply (SOS_CD_3690) or Source of Supply Modifier (SOSM_CD_2948)


Defense Logistics Agency, Enterprise Business Systems

J

Acquisition Advice Code (AAC_2507)


NOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition.

U

Controlled Item Inventory Code (CIIC_2863)


Unclassified

1

Quantity Unit Pack (QUP_6106)


1

N

Reparability Code (REP_CD_DLA_2934 / REP_CD_CG_0709 / ERRC_CD_AF_2655 / RECOV_CD_MC_2891 / RECOV_CD_AR_2892 / MAT_CTL_NVY_2832)


AIR FORCE ERRC XB3: Stock Fund (Except Munitions); DLA: This item has been reviewed and a determination made that the item cannot or should not be restored to a serviceable condition from an unserviceable condition; NAVY: 1I cog not stocked print on demand flat forms

FT

Unit of Issue (UI_3050)


Foot - Unit of linear measurement, sometimes expressed as “linear foot”.

0

Shelf Life Code (SLC_2943)


TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.

DF

Service / Agency Code (MOE_CD_2833)


Department of the Air Force

DS

Service / Agency Code (MOE_CD_2833)


Defense Logistics Agency


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 6145-01-354-2603 Submit RFQ
MRCDecoded RequirementClear Text Reply
AMQNConductor Quantity7
CXCWConductor FormSTRANDED ALL CONDUCTORS
MATTMaterialCOPPER CORE CONDUCTOR ALL CONDUCTORS
MATTMaterialPLASTIC POLYVINYL CHLORIDE 1ST POSITION PRIMARY INSULATION ALL CONDUCTORS
MATTMaterialGLASS FIBER 2ND POSITION BRAID, NON-METALLIC ALL CONDUCTORS
MATTMaterialPLASTIC NYLON 3RD POSITION JACKET ALL CONDUCTORS
SFTTSurface TreatmentTIN CORE CONDUCTOR CABLE
SFTTSurface TreatmentTIN 4TH POSITION SHIELD BRAID, METALLIC CABLE
STDCSurface Treatment Document And ClassificationASTM B33 ASSN STD SINGLE TREATMENT RESPONSE CORE CONDUCTOR ALL CONDUCTORS
CXDCRound Conductor Size18 AWG ALL CONDUCTORS
BLNZStrand Quantity Per Conductor19 ALL CONDUCTORS
CXDGStrand Awg Size Per Conductor30 ALL CONDUCTORS
CXDQConductor Arrangement And Quantity7 SINGLES
HUESColorWHITE 1ST POSITION PRIMARY INSULATION FIRST CONDUCTOR
HUESColorRED 1ST POSITION PRIMARY INSULATION SECOND CONDUCTOR
HUESColorRED 1ST POSITION PRIMARY INSULATION THIRD CONDUCTOR
HUESColorRED 1ST POSITION PRIMARY INSULATION FIFTH CONDUCTOR
HUESColorRED 1ST POSITION PRIMARY INSULATION SIXTH CONDUCTOR
HUESColorRED 1ST POSITION PRIMARY INSULATION SEVENTH CONDUCTOR
HUESColorRED 1ST POSITION TUBE FOURTH CONDUCTOR
HUESColorWHITE 6TH POSITION BRAID, NON-METALLIC CABLE
ASGFTracer ColorBLUE SINGLE TRACER SECOND CONDUCTOR
ASGFTracer ColorYELLOW SINGLE TRACER THIRD CONDUCTOR
ASGFTracer ColorGREEN SINGLE TRACER FOURTH CONDUCTOR
ASGFTracer ColorWHITE SINGLE TRACER FIFTH CONDUCTOR
ASGFTracer ColorBLACK SINGLE TRACER SIXTH CONDUCTOR
ASGFTracer ColorBROWN SINGLE TRACER SEVENTH CONDUCTOR
CXFKVoltage Rating600.0 MAXIMUM ROOT MEAN SQUARE (RMS) OPERATING VOLTAGE ALL CONDUCTORS
AAGRCross-Sectional Shape StyleROUND
ADVLCross Section Outside Diameter0.327 INCHES NOMINAL
ABJHTemp Rating105.0 DEG CELSIUS
MATTMaterialCOPPER 4TH POSITION SECONDARY INSULATION CABLE
MATTMaterialPLASTIC POLYETHYLENE TEREPHTHALATE 5TH POSITION TAPE CABLE
MATTMaterialPLASTIC POLYAMIDE 6TH POSITION BRAID, NON-METALLIC CABLE
MDCLMaterial Document And ClassificationASTM B33 ASSN STD SINGLE MATERIAL RESPONSE CORE CONDUCTOR ALL CONDUCTORS
MDCLMaterial Document And ClassificationASTM B33 ASSN STD SINGLE MATERIAL RESPONSE 4TH POSITION SHIELD BRAID, METALLIC CABLE


Back to Top
Back to Top