Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
836-4902177 | 3 - Design Control Reference | 2 - Production Item | SPECIALTY CABLE CORP. | 60685 | ![]() |
RSS5-129B22CSNJ | 3 - Design Control Reference | 9 - No Longer Used | ROCKBESTOS CO THE A MEMBER OF THE | 77872 | ![]() |
H17-3031 | 5 - Replaced / Discontinued | 9 - No Longer Used | ROCKBESTOS CO THE A MEMBER OF THE | 77872 | ![]() |
LE572-0006-0006 | 7 - Vendor Item Drawing Reference | 2 - Production Item | BOEING COMPANY, THE | 43999 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.
Vendor Item Drawing Reference (formerly Specification Control Reference). The number assigned by a design activity to a drawing that is not item-identifying, but which delineates existing commercial or vendor-developed items meeting all engineering and test requirements specified, without imposing additional test/engineering requirements not normally provided by the vendor(s). Includes only those drawings which meet the definition for Vendor Item Drawing in MIL-STD 100. Vendor Item Drawing References are administrative control numbers and shall not be used as part identification numbers.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
61 | 6145 | 013560143 | A077A0 | 16488 | X | 1 | A | N | A | 27 Mar 1992 |
Electric Wire, and Power and Distribution Equipment
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Full Descriptive Item Identification
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.
Item does not contain Precious Metal.
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
FXGX | FXTX | 3 | C | Z | SX | 1 Nov 2005 |
Acquire directly from the actual manufacturer, whether or not the prime contractor is the actual manufacturer.
This part requires engineering source approval by the design control activity in order to maintain the quality of the part. An alternate source must qualify in accordance with the design control activity's procedures, as approved by the cognizant Government engineering activity. Valid AMCs: 1, 2, 3, 4 and 5.
Integrated Management: Relinquishment of Service management of an item in designated commodity oriented Federal Supply Classes to the IMM (FSC manager) for management.
Oklahoma City Air Logistics Center, Tinker AFB, OK 73145-3043
RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
3 | 2 | 5 | ZZ | 836-4902177 | 60685 | ![]() | ||||||
3 | 9 | 5 | KZ | RSS5-129B22CSNJ | 77872 | ![]() | ||||||
5 | 9 | 5 | KZ | H17-3031 | 77872 | ![]() | ||||||
7 | 2 | A | KZ | LE572-0006-0006 | 43999 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
The reference number is represented by a drawing, but the drawing was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.
USA
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
Defense Supply Center Philadelphia, Philadelphia, PA 19101
Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.
Vendor Item Drawing Reference (formerly Specification Control Reference). The number assigned by a design activity to a drawing that is not item-identifying, but which delineates existing commercial or vendor-developed items meeting all engineering and test requirements specified, without imposing additional test/engineering requirements not normally provided by the vendor(s). Includes only those drawings which meet the definition for Vendor Item Drawing in MIL-STD 100. Vendor Item Drawing References are administrative control numbers and shall not be used as part identification numbers.
The reference number is represented by an engineering drawing and the drawing is available for unlimited use. The drawing will be furnished by the activity identified by the RNAAC upon request.
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
5 | 97 | 0 | 27 Mar 1992 |
An item authorized for procurement that has not yet been subject to item standardization.
DLIS-LFF, Battle Creek, MI 49037-3084
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
KH | 743 | Z | 9 | A | H | Z | W | 030310 | Z | 15080 | CABLE-OR-WIRE |
Defense Industrial Supply Center, Philadelphia, PA 19111
Electrical Cable
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
No special handling required.
Variable Rating
No Variation. NMFC and UFCC Match.
Defense Logistics Agency, Enterprise Business Systems
NOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition.
Unclassified
1
AIR FORCE ERRC XB3: Stock Fund (Except Munitions); DLA: This item has been reviewed and a determination made that the item cannot or should not be restored to a serviceable condition from an unserviceable condition; NAVY: 1I cog not stocked print on demand flat forms
Foot - Unit of linear measurement, sometimes expressed as “linear foot”.
TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.
500
Department of the Air Force
Defense Logistics Agency
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
CXCW | Conductor Form | STRANDED ALL CONDUCTORS |
CXDQ | Conductor Arrangement And Quantity | 3 SINGLES |
ADVL | Cross Section Outside Diameter | 0.230 INCHES NOMINAL |
AAGR | Cross-Sectional Shape Style | ROUND |
AMQN | Conductor Quantity | 3 |
MATT | Material | COPPER ALLOY CORE CONDUCTOR ALL CONDUCTORSMICA 1ST POSITION PRIMARY INSULATION ALL CONDUCTORSPLASTIC POLYTETRAFLUOROETHYLENE 2ND POSITION SECONDARY INSULATION ALL CONDUCTORS AND PLASTIC POLYIMIDE 2ND POSITION SECONDARY INSULATION ALL CONDUCTORSGLASS 3RD POSITION BRAID, NON-METALLIC ALL CONDUCTORS AND PLASTIC POLYTETRAFLUOROETHYLENE 3RD POSITION BRAID, NON-METALLIC ALL CONDUCTORSPLASTIC POLYTETRAFLUOROETHYLENE 4TH POSITION COATING ALL CONDUCTORSCOPPER 5TH POSITION SHIELD BRAID, METALLIC CABLEPLASTIC POLYTETRAFLUOROETHYLENE 6TH POSITION TAPE CABLEGLASS 7TH POSITION BRAID, NON-METALLIC CABLE AND PLASTIC POLYTETRAFLUOROETHYLENE 7TH POSITION BRAID, NON-METALLIC CABLEPLASTIC POLYTETRAFLUOROETHYLENE 8TH POSITION COATING CABLE |
CXDC | Round Conductor Size | 22 AWG ALL CONDUCTORS |
CXFK | Voltage Rating | 600.0 MAXIMUM ROOT MEAN SQUARE (RMS) OPERATING VOLTAGE ALL CONDUCTORS |
CXDG | Strand Awg Size Per Conductor | 34 ALL CONDUCTORS |
BLNZ | Strand Quantity Per Conductor | 19 ALL CONDUCTORS |
SFTT | Surface Treatment | NICKEL CORE CONDUCTOR ALL CONDUCTORSNICKEL 5TH POSITION SHIELD BRAID, METALLIC CABLE |
ABJH | Temp Rating | 260.0 DEG CELSIUS |