6145-01-384-9541

CABLE,SPECIAL PURPOSE,ELECTRICAL


6145-01-384-9541 (6145013849541, 013849541)
Part Number : None
Summary

FSG 61 / FSC 6145

DEMIL: A

DEMIL INT:

HMIC: N

Date Created: 29 Dec 1993

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 6145-01-384-9541 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
Code Definitions

FLIS - SEG A - IDENTIFICATION | NSN 6145-01-384-9541 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
616145013849541A077A016488X1ANA029 Dec 1993
Code Definitions

61

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electric Wire, and Power and Distribution Equipment

6145

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Wire and Cable, Electrical

013849541

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 6145-01-384-9541

A077A0

Federal Item Identification Guide (FIIG_4065)

16488

Item Naming Code (INC_4080)

29 Dec 1993

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

1

Type of Item Identification (TYP_II_4820)


Full Descriptive Item Identification

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

A

Precious Metals Indicator Code (PMIC_0802)


Item does not contain Precious Metal.

0

ADPE Identification Code (ADPEC_0801)


Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)


FLIS - SEG B - MOE RULE DATA | NSN 6145-01-384-9541 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
YB011 Sep 1995
N9BNN9ND00ZGHKE1 Nov 2005
Code Definitions

0

Acquisition Method Code (AMC_2871)


Not Established

Z

Item Management Code (IMC_2744)


Integrated Management: Relinquishment of Service management of an item in designated commodity oriented Federal Supply Classes to the IMM (FSC manager) for management.

GH

Item Management Coding Activity (IMC_ACTY_2748)


Naval Inventory Control Point, Mechanicsburg, PA 17055-0788

KECollaborators

Supplementary Collaborators (SUPPLM_COLLBR_2533)


Naval ICP, Philadelphia, PA 19111


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 6145-01-384-9541 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
597029 Dec 1993
Code Definitions

5

Item Standardization Code (ISC_2650)


An item authorized for procurement that has not yet been subject to item standardization.

97

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


DLIS-LFF, Battle Creek, MI 49037-3084

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

29 Dec 1993

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 6145-01-384-9541 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
KZ743Z9AHZW030310Z15080CABLE-OR-WIRE
Code Definitions

KZ

Originating Activity Code (ORIG_ACTY_CD_4210)


Defense Supply Center Philadelphia, Philadelphia, PA 19101

743

Water Commodity Code (WRT_CMDTY_CD_9275)


Electrical Cable

Z

Type Cargo Code (TYPE_CGO_CD_9260)


No special type of cargo code applicable

9

Special Handling Code (SP_HDLG_CD_9240)


No special handling required

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

H

Air Commodity Code (AIR_CMTY_HDLG_9215)


Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.

Z

Air Special Handling Code (AIR_CMTY_HDLG_9215)


No special handling required.

W

Less Than Truckload (CLAS_RTNG_CD_2770)


Variable Rating

030310

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

Z

NMFC Sub Item Number (SUB_ITM_NBR_0861)

15080

Uniform Freight Classification (UFC_CD_MODF_3040)

CABLE-OR-WIRE

Freight Description (FRT_DESC_4020)

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG H - MANAGEMENT DATA | NSN 6145-01-384-9541 Submit RFQ
Unit PriceMOESOSAACCIICQUPReparabilityUISLC
DNSMSZU1FT0
DSSMSZU1FT0
Code Definitions

SMS

Source of Supply (SOS_CD_3690) or Source of Supply Modifier (SOSM_CD_2948)


Defense Logistics Agency, Enterprise Business Systems

Z

Acquisition Advice Code (AAC_2507)


INSURANCE/NUMERIC STOCKAGE OBJECTIVE ITEM. Items which may be required occasionally or intermittently, and prudence requires that a nominal quantity of materiel be stocked due to the essentiality or the lead time of the item. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with IMM/Service requisitioning procedures.

U

Controlled Item Inventory Code (CIIC_2863)


Unclassified

1

Quantity Unit Pack (QUP_6106)


1

FT

Unit of Issue (UI_3050)


Foot - Unit of linear measurement, sometimes expressed as “linear foot”.

0

Shelf Life Code (SLC_2943)


TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.

DN

Service / Agency Code (MOE_CD_2833)


Department of the Navy

DS

Service / Agency Code (MOE_CD_2833)


Defense Logistics Agency


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 6145-01-384-9541 Submit RFQ
MRCDecoded RequirementClear Text Reply
HUESColorBLACK 4TH POSITION JACKET CABLE
HUESColorWHITE 1ST POSITION PRIMARY INSULATION ALL CONDUCTORS
CXCWConductor FormSTRANDED ALL CONDUCTORS
CXDQConductor Arrangement And Quantity1 TRIPLES
ADVLCross Section Outside Diameter0.204 INCHES NOMINAL
AAGRCross-Sectional Shape StyleROUND
AMQNConductor Quantity3
MATTMaterialCOPPER 3RD POSITION SHIELD BRAID, METALLIC CABLE
MATTMaterialCOPPER CORE CONDUCTOR ALL CONDUCTORS
MATTMaterialPLASTIC POLYVINYL CHLORIDE 1ST POSITION PRIMARY INSULATION ALL CONDUCTORS
MATTMaterialPLASTIC POLYVINYL CHLORIDE 4TH POSITION JACKET CABLE
MATTMaterialPLASTIC POLYETHYLENE TEREPHTHALATE 2ND POSITION TAPE CABLE
MDCLMaterial Document And ClassificationASTM B33 ASSN STD SINGLE MATERIAL RESPONSE CORE CONDUCTOR ALL CONDUCTORS
CXDCRound Conductor Size20 AWG ALL CONDUCTORS
FEATSpecial FeaturesCONDUCTORS ARE NUMBERED CONSECUTIVELY IN BLACK ON WHITE INSULATION AT APPROXIMATELEY 1 INCH INTERVALS.
CXFKVoltage Rating600.0 MAXIMUM ROOT MEAN SQUARE (RMS) OPERATING VOLTAGE ALL CONDUCTORS
CXDGStrand Awg Size Per Conductor28 ALL CONDUCTORS
BLNZStrand Quantity Per Conductor7 ALL CONDUCTORS
STDCSurface Treatment Document And ClassificationASTM B33 ASSN STD SINGLE TREATMENT RESPONSE CORE CONDUCTOR ALL CONDUCTORS
SFTTSurface TreatmentTIN 3RD POSITION SHIELD BRAID, METALLIC CABLE
SFTTSurface TreatmentTIN CORE CONDUCTOR ALL CONDUCTORS
ABJHTemp Rating-40.0 DEG CELSIUS AND 105.0 DEG CELSIUS


Back to Top
Back to Top