Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
80216 | 3 - Design Control Reference | 2 - Production Item | SOUTH BAY CABLE CORP. | 20857 | ![]() |
5266823 | 5 - Replaced / Discontinued | 2 - Production Item | NAVAL SEA SYSTEMS COMMAND | 53711 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
61 | 6145 | 014071696 | A077A0 | 16488 | X | 1 | A | N | A | 0 | 22 Jan 1995 |
Electric Wire, and Power and Distribution Equipment
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Full Descriptive Item Identification
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.
Item does not contain Precious Metal.
Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
N9BN | N9ND | 0 | 0 | Z | GH | HD | 1 Nov 2005 |
Not Established
Integrated Management: Relinquishment of Service management of an item in designated commodity oriented Federal Supply Classes to the IMM (FSC manager) for management.
Naval Inventory Control Point, Mechanicsburg, PA 17055-0788
Naval Inventory Control Point, Mechanicsburg, PA 17055-0788
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
The reference number is represented by a drawing, but the drawing was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.
USA
Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.
The reference number is represented by an engineering drawing and the drawing is available for unlimited use. The drawing will be furnished by the activity identified by the RNAAC upon request.
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
5 | 97 | 0 | 22 Jan 1995 |
An item authorized for procurement that has not yet been subject to item standardization.
DLIS-LFF, Battle Creek, MI 49037-3084
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
KZ | 743 | Z | 9 | A | H | Z | W | 030310 | Z | 15080 | CABLE-OR-WIRE |
Defense Supply Center Philadelphia, Philadelphia, PA 19101
Electrical Cable
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
No special handling required.
Variable Rating
No Variation. NMFC and UFCC Match.
Defense Logistics Agency, Enterprise Business Systems
INSURANCE/NUMERIC STOCKAGE OBJECTIVE ITEM. Items which may be required occasionally or intermittently, and prudence requires that a nominal quantity of materiel be stocked due to the essentiality or the lead time of the item. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with IMM/Service requisitioning procedures.
Unclassified
1
Foot - Unit of linear measurement, sometimes expressed as “linear foot”.
TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.
Department of the Navy
Defense Logistics Agency
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
HUES | Color | BLACK 1ST POSITION PRIMARY INSULATION FIRST CONDUCTOR |
HUES | Color | ORANGE 1ST POSITION PRIMARY INSULATION NINTH CONDUCTOR |
HUES | Color | RED 1ST POSITION PRIMARY INSULATION THIRD CONDUCTOR |
HUES | Color | WHITE 1ST POSITION PRIMARY INSULATION SECOND CONDUCTOR |
HUES | Color | BROWN 1ST POSITION PRIMARY INSULATION FOURTH CONDUCTOR |
HUES | Color | GREEN 1ST POSITION PRIMARY INSULATION EIGHTH CONDUCTOR |
HUES | Color | GREEN 1ST POSITION PRIMARY INSULATION SIXTH CONDUCTOR |
HUES | Color | YELLOW 1ST POSITION PRIMARY INSULATION FIFTH CONDUCTOR |
HUES | Color | YELLOW 1ST POSITION PRIMARY INSULATION SEVENTH CONDUCTOR |
CXCW | Conductor Form | STRANDED SINGLE CONDUCTOR |
CXFG | Conductor Sequence Within Groups | FIFTH CONDUCTOR THIRD GROUP AND SIXTH CONDUCTOR THIRD GROUP |
CXFG | Conductor Sequence Within Groups | FIRST CONDUCTOR FIRST GROUP AND SECOND CONDUCTOR FIRST GROUP |
CXFG | Conductor Sequence Within Groups | SEVENTH CONDUCTOR FOURTH GROUP AND EIGHTH CONDUCTOR FOURTH GROUP AND NINTH CONDUCTOR FOURTH GROUP |
CXFG | Conductor Sequence Within Groups | THIRD CONDUCTOR SECOND GROUP AND FOURTH CONDUCTOR SECOND GROUP |
CXDQ | Conductor Arrangement And Quantity | 2 SINGLES AND 2 TWISTED PAIR AND 1 TRIPLES |
ADVL | Cross Section Outside Diameter | 0.665 INCHES NOMINAL |
AAGR | Cross-Sectional Shape Style | ROUND |
CXDT | Group Quantity | 4 |
AMQN | Conductor Quantity | 9 |
MATT | Material | COPPER 2ND POSITION SHIELD BRAID, METALLIC SECOND CONDUCTOR |
MATT | Material | COPPER 2ND POSITION SHIELD BRAID, METALLIC FIRST CONDUCTOR |
MATT | Material | COPPER 5TH POSITION SHIELD BRAID, METALLIC THIRD GROUP |
MATT | Material | COPPER CORE CONDUCTOR ALL CONDUCTORS |
MATT | Material | PLASTIC POLYETHYLENE 1ST POSITION PRIMARY INSULATION FIRST CONDUCTOR |
MATT | Material | PLASTIC POLYETHYLENE 1ST POSITION PRIMARY INSULATION SECOND CONDUCTOR |
MATT | Material | PLASTIC POLYETHYLENE TEREPHTHALATE 4TH POSITION TAPE ALL GROUPS |
MATT | Material | PLASTIC POLYETHYLENE TEREPHTHALATE 3RD POSITION TAPE FIRST CONDUCTOR |
MATT | Material | PLASTIC POLYETHYLENE TEREPHTHALATE 3RD POSITION TAPE SECOND CONDUCTOR |
MATT | Material | PLASTIC POLYPROPYLENE 1ST POSITION PRIMARY INSULATION EIGHTH CONDUCTOR |
MATT | Material | PLASTIC POLYPROPYLENE 1ST POSITION PRIMARY INSULATION FIFTH CONDUCTOR |
MATT | Material | PLASTIC POLYPROPYLENE 1ST POSITION PRIMARY INSULATION FOURTH CONDUCTOR |
MATT | Material | PLASTIC POLYPROPYLENE 1ST POSITION PRIMARY INSULATION NINTH CONDUCTOR |
MATT | Material | PLASTIC POLYPROPYLENE 1ST POSITION PRIMARY INSULATION SEVENTH CONDUCTOR |
MATT | Material | PLASTIC POLYPROPYLENE 1ST POSITION PRIMARY INSULATION SIXTH CONDUCTOR |
MATT | Material | PLASTIC POLYPROPYLENE 1ST POSITION PRIMARY INSULATION THIRD CONDUCTOR |
MATT | Material | PLASTIC POLYURETHANE 6TH POSITION JACKET CABLE |
CXDC | Round Conductor Size | 16 AWG 3RD CONDUCTOR |
CXDC | Round Conductor Size | 16 AWG 4TH CONDUCTOR |
CXDC | Round Conductor Size | 16 AWG 5TH CONDUCTOR |
CXDC | Round Conductor Size | 16 AWG 6TH CONDUCTOR |
CXDC | Round Conductor Size | 18 AWG 7TH CONDUCTOR |
CXDC | Round Conductor Size | 18 AWG 8TH CONDUCTOR |
CXDC | Round Conductor Size | 18 AWG 9TH CONDUCTOR |
CXDC | Round Conductor Size | 22 AWG 1ST CONDUCTOR |
CXDC | Round Conductor Size | 22 AWG 2ND CONDUCTOR |
CXDG | Strand Awg Size Per Conductor | 26 7TH CONDUCTOR |
CXDG | Strand Awg Size Per Conductor | 26 8TH CONDUCTOR |
CXDG | Strand Awg Size Per Conductor | 26 9TH CONDUCTOR |
CXDG | Strand Awg Size Per Conductor | 30 1ST CONDUCTOR |
CXDG | Strand Awg Size Per Conductor | 30 2ND CONDUCTOR |
CXDG | Strand Awg Size Per Conductor | 29 3RD CONDUCTOR |
CXDG | Strand Awg Size Per Conductor | 29 4TH CONDUCTOR |
CXDG | Strand Awg Size Per Conductor | 29 5TH CONDUCTOR |
CXDG | Strand Awg Size Per Conductor | 29 6TH CONDUCTOR |
BLNZ | Strand Quantity Per Conductor | 19 6TH CONDUCTOR |
BLNZ | Strand Quantity Per Conductor | 19 3RD CONDUCTOR |
BLNZ | Strand Quantity Per Conductor | 19 4TH CONDUCTOR |
BLNZ | Strand Quantity Per Conductor | 19 5TH CONDUCTOR |
BLNZ | Strand Quantity Per Conductor | 7 7TH CONDUCTOR |
BLNZ | Strand Quantity Per Conductor | 7 8TH CONDUCTOR |
BLNZ | Strand Quantity Per Conductor | 7 9TH CONDUCTOR |
BLNZ | Strand Quantity Per Conductor | 7 1ST CONDUCTOR |
BLNZ | Strand Quantity Per Conductor | 7 2ND CONDUCTOR |
SFTT | Surface Treatment | TIN 2ND POSITION SHIELD BRAID, METALLIC FIRST CONDUCTOR |
SFTT | Surface Treatment | TIN 2ND POSITION SHIELD BRAID, METALLIC SECOND CONDUCTOR |
SFTT | Surface Treatment | TIN 3RD POSITION SHIELD BRAID, METALLIC THIRD GROUP |
SFTT | Surface Treatment | TIN CORE CONDUCTOR ALL CONDUCTORS |
ABJH | Temp Rating | -28.0 DEG CELSIUS AND 65.0 DEG CELSIUS |