6145-01-495-0668

CABLE,RADIO FREQUENCY


6145-01-495-0668 (6145014950668, 014950668)
Part Numbers (3 listings): 7726D066A | T-14707 | 5PTM1T04-1 |
Summary

FSG 61 / FSC 6145

DEMIL: A

DEMIL INT: 1

HMIC: N

Date Created: 5 Mar 2002

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 6145-01-495-0668 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
7726D066A3 - Design Control Reference2 - Production ItemTYCO ELECTRONICS CORPORATION  06090    CAGE 06090  
T-147075 - Replaced / Discontinued2 - Production ItemGENERAL CABLE INDUSTRIES, INC.  71124    CAGE 71124  
5PTM1T04-17 - Vendor Item Drawing Reference2 - Production ItemLOCKHEED MARTIN CORPORATION  98897    CAGE 98897  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

5 - Replaced / Discontinued

Reference Number Category Code (DRN_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

7 - Vendor Item Drawing Reference

Reference Number Category Code (DRN_2910)


Vendor Item Drawing Reference (formerly Specification Control Reference). The number assigned by a design activity to a drawing that is not item-identifying, but which delineates existing commercial or vendor-developed items meeting all engineering and test requirements specified, without imposing additional test/engineering requirements not normally provided by the vendor(s). Includes only those drawings which meet the definition for Vendor Item Drawing in MIL-STD 100. Vendor Item Drawing References are administrative control numbers and shall not be used as part identification numbers.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.


FLIS - SEG A - IDENTIFICATION | NSN 6145-01-495-0668 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
616145014950668A077A000779X1ANA05 Mar 2002
Code Definitions

61

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electric Wire, and Power and Distribution Equipment

6145

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Wire and Cable, Electrical

014950668

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 6145-01-495-0668

A077A0

Federal Item Identification Guide (FIIG_4065)

00779

Item Naming Code (INC_4080)

5 Mar 2002

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

1

Type of Item Identification (TYP_II_4820)


Full Descriptive Item Identification

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

A

Precious Metals Indicator Code (PMIC_0802)


Item does not contain Precious Metal.

0

ADPE Identification Code (ADPEC_0801)


Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)


FLIS - SEG B - MOE RULE DATA | NSN 6145-01-495-0668 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
FLL500B1 Mar 2002
Code Definitions

0

Acquisition Method Code (AMC_2871)


Not Established

B

Item Management Code (IMC_2744)


Performance Based Logistics or Contractor Logistics Support: Consumable items that are unique to a weapon system which have been included in a Performance Based Logistics (PBL) or Contractor Logistics Support (CLS) contract. (PICA LOA must be 06 or 23).


FLIS - SEG C - REFERENCE NUMBER | NSN 6145-01-495-0668 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
323ZZ7726D066A  06090   CAGE/06090
525ZZT-14707  71124   CAGE/71124
722ZZ5PTM1T04-1  98897   CAGE/98897
Code Definitions

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

3

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the technical documentation upon request.

ZZ

Reference Number Action Activity Code (RNAAC_2900)


USA

5

Reference Number Category Code (RNCC_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

5

Document Availability Code (DAC_2640)


The reference number is represented by a drawing, but the drawing was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.

7

Reference Number Category Code (RNCC_2910)


Vendor Item Drawing Reference (formerly Specification Control Reference). The number assigned by a design activity to a drawing that is not item-identifying, but which delineates existing commercial or vendor-developed items meeting all engineering and test requirements specified, without imposing additional test/engineering requirements not normally provided by the vendor(s). Includes only those drawings which meet the definition for Vendor Item Drawing in MIL-STD 100. Vendor Item Drawing References are administrative control numbers and shall not be used as part identification numbers.

2

Document Availability Code (DAC_2640)


The reference number is represented by a drawing and the drawing was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the drawing.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 6145-01-495-0668 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
59705 Mar 2002
Code Definitions

5

Item Standardization Code (ISC_2650)


An item authorized for procurement that has not yet been subject to item standardization.

97

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


DLIS-LFF, Battle Creek, MI 49037-3084

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

5 Mar 2002

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 6145-01-495-0668 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
TK
Code Definitions

TK

Originating Activity Code (ORIG_ACTY_CD_4210)


HQ AFMC/GLSC 401 SCM/GUMB, Wright-Patterson AFB, OH 45433-5000

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG H - MANAGEMENT DATA | NSN 6145-01-495-0668 Submit RFQ
Unit PriceMOESOSAACCIICQUPReparabilityUISLC
DFF01DU1NFT0
DFF01DU1FT0
Code Definitions

F01

Source of Supply (SOS_CD_3690) or Source of Supply Modifier (SOSM_CD_2948)


Lockheed Martin Aeronautical Systems, Eagle Global Logistics, FOR DEPOT STORAGE, 15001 Peterson CT, Fort Worth, TX 76177-2324

D

Acquisition Advice Code (AAC_2507)


DoD INTEGRATED MATERIEL-MANAGED, STOCKED, AND ISSUED. Issue, transfer, or shipment is not subject to specialized controls other than those imposed by the Integrated Materiel Manager/Service supply policy. 1. The item is centrally managed, stocked, and issued. 2. Requisitions must contain the fund citation required to acquire the item. Requisitions will be submitted in accordance with Integrated Materiel Manager(IMM)/Service requisitioning procedures.

U

Controlled Item Inventory Code (CIIC_2863)


Unclassified

1

Quantity Unit Pack (QUP_6106)


1

N

Reparability Code (REP_CD_DLA_2934 / REP_CD_CG_0709 / ERRC_CD_AF_2655 / RECOV_CD_MC_2891 / RECOV_CD_AR_2892 / MAT_CTL_NVY_2832)


AIR FORCE ERRC XB3: Stock Fund (Except Munitions); DLA: This item has been reviewed and a determination made that the item cannot or should not be restored to a serviceable condition from an unserviceable condition; NAVY: 1I cog not stocked print on demand flat forms

FT

Unit of Issue (UI_3050)


Foot - Unit of linear measurement, sometimes expressed as “linear foot”.

0

Shelf Life Code (SLC_2943)


TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.

DF

Service / Agency Code (MOE_CD_2833)


Department of the Air Force


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 6145-01-495-0668 Submit RFQ
MRCDecoded RequirementClear Text Reply
AMQNConductor Quantity2
CXCWConductor FormSTRANDED ALL CONDUCTORS
MATTMaterialCOPPER ALLOY CORE CONDUCTOR ALL CONDUCTORS
MATTMaterialPLASTIC ETHYLENE-TETRAFLUOROETHYLENE 1ST POSITION PRIMARY INSULATION ALL CONDUCTORS
MATTMaterialCOPPER ALLOY 2ND POSITION SHIELD BRAID, METALLIC ALL CONDUCTORS
MATTMaterialPLASTIC ETHYLENE-TETRAFLUOROETHYLENE 3RD POSITION JACKET ALL CONDUCTORS
CXDCRound Conductor Size26 AWG ALL CONDUCTORS
BLNZStrand Quantity Per Conductor19 ALL CONDUCTORS
CXDGStrand Awg Size Per Conductor38 ALL CONDUCTORS
AXGHNominal Capacitance In Picofarads30.0 PER FOOT
AAPPElectrical Resistance77.00 OHMS IMPEDANCE
AAGRCross-Sectional Shape StyleROUND
FEATSpecial FeaturesCOMPONENT WIRE IN THE -1 CONDUCTOR CONTAINS "CS95 BERYLLIUM COPPER"


Back to Top
Back to Top