| Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
|---|---|---|---|---|---|
| 81665 | 3 - Design Control Reference | 2 - Production Item | GENERAL CABLE CORPORATION | 81774 | |
| 81665.99.01 | 5 - Replaced / Discontinued | 2 - Production Item | GENERAL CABLE CORPORATION | 81774 | |
| 81665-21-01 | 5 - Replaced / Discontinued | 2 - Production Item | GENERAL CABLE CORPORATION | 81774 | |
| 571483 | 5 - Replaced / Discontinued | 2 - Production Item | SOUTHWIRE CO | 22123 | |
| 079407016655 | 5 - Replaced / Discontinued | 2 - Production Item | GENERAL CABLE CORPORATION | 81774 | |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
| FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 61 | 6145 | 015182622 | A077A0 | 00232 | X | 4 | 6 | A | N | A | A | 0 | 5 Mar 2004 |
Electric Wire, and Power and Distribution Equipment
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Partial Descriptive Item Identification (Type 1 Concept)
An approved item name and FIIG may exist, but it has previously been established and documented that industry refuses to provide the technical data sufficient for preparation on a full descriptive method item identification based on policy, restricted or proprietary data rights, nonexistence of technical data, etc.
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.
No known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity.
Item does not contain Precious Metal.
Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
| MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| ZC01 | 1 Mar 2004 | |||||||||||||||||||||||||||||
| RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 4 | 3 | 2 | 4 | 9Z | D | 81665 | 81774 | | ||||
| 4 | 5 | 2 | 6 | 9Z | D | 81665-21-01 | 81774 | | ||||
| 4 | 5 | 2 | 4 | 9Z | D | 81665.99.01 | 81774 | | ||||
| 4 | 5 | 2 | 4 | 9Z | D | 571483 | 22123 | | ||||
| 4 | 5 | 2 | 4 | 9Z | D | 079407016655 | 81774 | | ||||
Number is totally in-the-clear (without modification) as originally configured by the manufacturer, design control activity, or supplier.
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the technical documentation.
DLIS-K, Battle Creek, MI 49037-3084
Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.
Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.
The reference number is represented by technical documentation other than a drawing but the documentation was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.
| ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
|---|---|---|---|---|---|---|---|---|
| 5 | 97 | 0 | 5 Mar 2004 |
An item authorized for procurement that has not yet been subject to item standardization.
DLIS-LFF, Battle Creek, MI 49037-3084
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
| Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| DF |
U.S. Army Tank Automotive Command, Warren, MI 48090
No Variation. NMFC and UFCC Match.
| MRC | Decoded Requirement | Clear Text Reply |
|---|---|---|
| CXDM | Conductor Cross-Sectional Shape | TUBULAR SOLID ALL CONDUCTORS |
| CXCW | Conductor Form | STRANDED ALL CONDUCTORS |
| CXDQ | Conductor Arrangement And Quantity | 5 MOLDED |
| ADVL | Cross Section Outside Diameter | 1.610 INCHES NOMINAL |
| AAGR | Cross-Sectional Shape Style | ROUND |
| CXDT | Group Quantity | 1 |
| AMQN | Conductor Quantity | 5 |
| ABKV | Outside Diameter | 1.610 INCHES NOMINAL ALL CONDUCTORS |
| MATT | Material | COPPER CORE CONDUCTOR ALL CONDUCTORS |
| CXDC | Round Conductor Size | 5 AWG ALL CONDUCTORS |
| CXCY | Part Name Assigned By Controlling Agency | CAROL BRAND INDUSTRIAL-GRADE CABLE, SUPER VU-TRON, TYPE W, ROUND, 90 DEG C, 2000 VOLTS, NO OF CONDUCTORS 5, CONDUCTOR SIZE 2 AWG/KCMIL, CONDUCTOR/STRANDS 259-BLACK, FACTORY REEL |
| FEAT | Special Features | MULTI CONDUCTOR; CONDUCTOR FULLY ANNEALED, STRANDED BARE COPPER; INSULATION COLOR CODED, PREMIUM GRADE COLOR CODED 90 DEG C; JACKET SUPER VU-TRON 90 DEG C, BLACK; JACKET COLOR BLACK; CURRENT AMPS 121; APPROXIMATE NET WEIGHT LBS PER 1,000 FT 2340; UPC 079407016655; SCC-14 5007-94-070-16655; WEIGHT PER UNIT OF MEASURE 1.942; APPLICATION 5 CONDUCTOR CABLES USE IN APPLICATIONS WHERE SEPARATING THE SYSTEM NEUTRAL FROM THE FRAME GROUND IS REQUIRED |
| CXDG | Strand Awg Size Per Conductor | 2 ALL CONDUCTORS |
| BLNZ | Strand Quantity Per Conductor | 259 ALL CONDUCTORS |
| ABJH | Temp Rating | -40.0 DEG CELSIUS AND 90.0 DEG CELSIUS |