| Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
|---|---|---|---|---|---|
| HP3-EXBHE1 | 3 - Design Control Reference | 1 - Incomplete Part Number | NATIONAL ELECTRICAL MFRS ASSN | 1P787 | |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.
| FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 61 | 6145 | 016524438 | A077A0 | 00798 | X | 1 | A | N | A | S | 0 | 23 Feb 2016 |
Electric Wire, and Power and Distribution Equipment
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Full Descriptive Item Identification
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.
No known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity.
Item contains silver.
Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
| MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| FUGX | 0 | 0 | Z | SU | 1 Feb 2016 | |||||||||||||||||||||||||
Not Established
Integrated Management: Relinquishment of Service management of an item in designated commodity oriented Federal Supply Classes to the IMM (FSC manager) for management.
Ogden Air Logistics Center, Hill AFB, UT 84056-5609
| RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 3 | 1 | E | ZZ | HP3-EXBHE1 | 1P787 | | ||||||
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.
The reference number is represented by engineering data other than an engineering drawing. The data is available for unlimited use and will be furnished by the activity identified by the RNAAC upon request.
USA
| Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| GX | 743 | Z | 9 | A | H | Z | W | 030310 | Z | 15080 | CABLE-OR-WIRE |
HQ Defense Logistics Agency, Enterprise Business, Systems, Fort Belvoir, VA 22060
Electrical Cable
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
No special handling required.
Variable Rating
No Variation. NMFC and UFCC Match.
Defense Logistics Agency, Enterprise Business Systems
INSURANCE/NUMERIC STOCKAGE OBJECTIVE ITEM. Items which may be required occasionally or intermittently, and prudence requires that a nominal quantity of materiel be stocked due to the essentiality or the lead time of the item. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with IMM/Service requisitioning procedures.
Unclassified
No QUP
AIR FORCE ERRC XB3: Stock Fund (Except Munitions); DLA: This item has been reviewed and a determination made that the item cannot or should not be restored to a serviceable condition from an unserviceable condition; NAVY: 1I cog not stocked print on demand flat forms
Foot - Unit of linear measurement, sometimes expressed as “linear foot”.
TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.
Department of the Air Force
Defense Logistics Agency
| MRC | Decoded Requirement | Clear Text Reply |
|---|---|---|
| HUES | Color | BROWN CORE PRIMARY INSULATION ALL CONDUCTORS |
| CXCW | Conductor Form | STRANDED ALL CONDUCTORS |
| AAGR | Cross-Sectional Shape Style | ROUND |
| AGAV | End Item Identification | MOBILE UNIT |
| MDCL | Material Document And Classification | ASTM B 3 NATIONAL STD/SPEC SINGLE MATERIAL RESPONSE CORE CONDUCTOR ALL CONDUCTORS |
| MDCL | Material Document And Classification | ASTM D 4895 NATIONAL STD/SPEC SINGLE MATERIAL RESPONSE CORE PRIMARY INSULATION ALL CONDUCTORS |
| MATT | Material | COPPER CORE CONDUCTOR ALL CONDUCTORS |
| MATT | Material | PLASTIC POLYTETRAFLUOROETHYLENE CORE PRIMARY INSULATION ALL CONDUCTORS |
| CXCY | Part Name Assigned By Controlling Agency | INSULATED HIGH TEMPERATURE HOOK-UP WIRE TYPE E |
| PMLC | Precious Material And Location | CONDUCTOR COATING SILVER |
| PRMT | Precious Material | SILVER |
| CXDC | Round Conductor Size | 18 AWG ALL CONDUCTORS |
| ABKV | Outside Diameter | 0.074 INCHES MAXIMUM ALL CONDUCTORS |
| CXFK | Voltage Rating | 600.0 MAXIMUM ROOT MEAN SQUARE (RMS) OPERATING VOLTAGE ALL CONDUCTORS |
| CXDG | Strand Awg Size Per Conductor | 30 ALL CONDUCTORS |
| BLNZ | Strand Quantity Per Conductor | 19 ALL CONDUCTORS |
| STDC | Surface Treatment Document And Classification | ASTM B 298 NATIONAL STD/SPEC SINGLE TREATMENT RESPONSE CORE CONDUCTOR ALL CONDUCTORS |
| SFTT | Surface Treatment | SILVER CORE CONDUCTOR ALL CONDUCTORS |