| Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
|---|---|---|---|---|---|
| 85164 | 3 - Design Control Reference | 2 - Production Item | BELDEN WIRE & CABLE CO | 3GY56 | |
| A8931-000042 | D - Drawing Number Reference | 9 - No Longer Used | AMHERST SYSTEMS, INC. | 1L4J7 | |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
Drawing Number Reference. A number assigned by a design activity to a drawing or other technical documentation which identifies a drawing/document that is related to an item of supply or production but does not qualify for assignment of codes 1,3,5,7, or C. Code D reference numbers will not be used in item-of-supply determinations.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
| FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 61 | 6145 | 016526346 | A077A0 | 16488 | X | 1 | A | N | A | A | 0 | 29 Feb 2016 |
Electric Wire, and Power and Distribution Equipment
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Full Descriptive Item Identification
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.
No known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity.
Item does not contain Precious Metal.
Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
| MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| FUGX | 0 | 0 | Z | SU | 1 Feb 2016 | |||||||||||||||||||||||||
Not Established
Integrated Management: Relinquishment of Service management of an item in designated commodity oriented Federal Supply Classes to the IMM (FSC manager) for management.
Ogden Air Logistics Center, Hill AFB, UT 84056-5609
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the technical documentation upon request.
USA
Drawing Number Reference. A number assigned by a design activity to a drawing or other technical documentation which identifies a drawing/document that is related to an item of supply or production but does not qualify for assignment of codes 1,3,5,7, or C. Code D reference numbers will not be used in item-of-supply determinations.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
The reference number is represented by an engineering drawing and the drawing is available for unlimited use. The drawing will be furnished by the activity identified by the RNAAC upon request.
| Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| GX | 743 | Z | 9 | A | H | Z | W | 030310 | Z | 15080 | CABLE-OR-WIRE |
HQ Defense Logistics Agency, Enterprise Business, Systems, Fort Belvoir, VA 22060
Electrical Cable
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
No special handling required.
Variable Rating
No Variation. NMFC and UFCC Match.
Defense Logistics Agency, Enterprise Business Systems
INSURANCE/NUMERIC STOCKAGE OBJECTIVE ITEM. Items which may be required occasionally or intermittently, and prudence requires that a nominal quantity of materiel be stocked due to the essentiality or the lead time of the item. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with IMM/Service requisitioning procedures.
Unclassified
No QUP
AIR FORCE ERRC XB3: Stock Fund (Except Munitions); DLA: This item has been reviewed and a determination made that the item cannot or should not be restored to a serviceable condition from an unserviceable condition; NAVY: 1I cog not stocked print on demand flat forms
Foot - Unit of linear measurement, sometimes expressed as “linear foot”.
TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.
Department of the Air Force
Defense Logistics Agency
| MRC | Decoded Requirement | Clear Text Reply |
|---|---|---|
| AWTB | Accessory Wire Type And Quantity | 1 DRAIN |
| CXCW | Conductor Form | STRANDED ALL CONDUCTORS |
| AAGR | Cross-Sectional Shape Style | ROUND |
| CBBL | Features Provided | ROHS DIRECTIVE COMPLIANCE |
| AMQN | Conductor Quantity | 8 |
| AGAV | End Item Identification | MOBILE UNIT |
| MATT | Material | ALUMINUM CORE TAPE OVERALL |
| MATT | Material | PLASTIC ETHYLENE-TETRAFLUOROETHYLENE CORE PRIMARY INSULATION OVERALL |
| MATT | Material | TIN AND COPPER CORE CONDUCTOR OVERALL |
| CXCY | Part Name Assigned By Controlling Agency | CABLE, 20AWG 4 TWISTED PR |
| CXDC | Round Conductor Size | WG20 AWG ALL CONDUCTORS |
| FEAT | Special Features | CHARACTERISTIC IMPEDANCE IS 73 OHMS NOM;INDUCTANCE IS 0.186 MICROHENRIESNOM;CAPACITANCE CONDUCTOR TO CONDUCTOR IS 23 PF/FT;CAPACITANCE COND.TO OTHER CONDUCTOR AND SHIELD IS 40 PF/FT;CONDUCTOR DC RESISTANCE IS 9.3 OHM/1000FT;OPERATING VOLTAGE IS 300 V RMS MAX; RECOMMENDED CURRENT IS 4 AMPS PER CONDUCTORMAX AT 25C DEGREES |
| CXDG | Strand Awg Size Per Conductor | 28 ALL CONDUCTORS |
| BLNZ | Strand Quantity Per Conductor | 7 ALL CONDUCTORS |
| ABJH | Temp Rating | -60.0 DEG CELSIUS AND 150.0 DEG CELSIUS |