6145-14-205-1806

WIRE,ELECTRICAL


6145-14-205-1806 (6145142051806, 142051806)
Part Numbers (6 listings): 1600-0-60BJAUNE | 1600A0-60-4 | 1600A0-60B4 | 9666 | 9551812102 | 1600-0-60JAUNE |
Summary

FSG 61 / FSC 6145

DEMIL:

DEMIL INT:

HMIC:

Date Created: 1 Jan 1964

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 6145-14-205-1806 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
1600-0-60BJAUNE3 - Design Control Reference2 - Production ItemNEXANS FRANCE  F0241      
1600A0-60-45 - Replaced / Discontinued2 - Production ItemNEXANS FRANCE  F0241      
1600A0-60B45 - Replaced / Discontinued2 - Production ItemNEXANS FRANCE  F0241      
96665 - Replaced / Discontinued2 - Production ItemSOC EXPLOITATION MATERIELS  F0754      
95518121025 - Replaced / Discontinued2 - Production ItemTURBOMECA  F0228    CAGE F0228  
1600-0-60JAUNE5 - Replaced / Discontinued2 - Production ItemNEXANS FRANCE  F0241      
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

5 - Replaced / Discontinued

Reference Number Category Code (DRN_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.


FLIS - SEG A - IDENTIFICATION | NSN 6145-14-205-1806 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
6161451420518060079811 Jan 1964
Code Definitions

61

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electric Wire, and Power and Distribution Equipment

6145

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Wire and Cable, Electrical

142051806

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 6145-14-205-1806

00798

Item Naming Code (INC_4080)

1 Jan 1964

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

1

Type of Item Identification (TYP_II_4820)


Full Descriptive Item Identification


FLIS - SEG B - MOE RULE DATA | NSN 6145-14-205-1806 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
YA
YB
YW
ZD
ZF
ZP
Code Definitions

FLIS - SEG C - REFERENCE NUMBER | NSN 6145-14-205-1806 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
332637D1600-0-60BJAUNE  F0241  
352637D1600-0-60JAUNE  F0241  
352348D1600A0-60-4  F0241  
352637D1600A0-60B4  F0241  
352665D9666  F0754  
352637D9551812102  F0228   CAGE/F0228
Code Definitions

3

Reference Number Format Code (RNFC_2920)


Number format is unknown. (Coded RNFC 3 by the Defense Logistics Information Service upon implementation of FLIS.)

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

6

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing but the documentation was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.

37

Reference Number Action Activity Code (RNAAC_2900)


Department of Interior, Washington, DC 20006

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.

5

Reference Number Category Code (RNCC_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

3

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the technical documentation upon request.

48

Reference Number Action Activity Code (RNAAC_2900)


Federal Aviation Administration, Oklahoma City, OK 73125

65

Reference Number Action Activity Code (RNAAC_2900)


National Institutes of Health, Rockville, MD 20892




Back to Top
Back to Top