Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
A4-25283 | 3 - Design Control Reference | 2 - Production Item | STEWART AVIONICS INC | 96787 | |
67C35465-1 | 3 - Design Control Reference | 2 - Production Item | AIR FORCE UNITED STATES DEPARTMENT | 98748 | |
A4-25283 | 5 - Replaced / Discontinued | 9 - No Longer Used | DUPLEX DIV WARNER AND SWASEY CO | 18859 | |
67C35465-1 | 5 - Replaced / Discontinued | 9 - No Longer Used | SAN ANTONIO AIR LOGISTICS CENTER | 98750 |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
61 | 6150 | 000071725 | A077A0 | 04581 | X | 1 | A | N | U | 6 Jul 1972 |
Electric Wire, and Power and Distribution Equipment
Miscellaneous Electric Power and Distribution Equipment
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Full Descriptive Item Identification
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.
Precious Metal Content is unknown.
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
YJ01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZU01 | 1 Mar 2008 | |||||||||||||||||||||||||||||
ZH01 | 1 Sep 2013 |
RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
3 | 2 | 2 | ZZ | 67C35465-1 | 98748 |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
The reference number is represented by a drawing and the drawing was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the drawing.
USA
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
1 | CX | 0 | 3 | CX | 0 | 30 Jun 1988 | 6150001390814 | 2 Jul 1988 |
An item authorized for procurement as a result of a formal item reduction study and accepted as a replacement for one or more items not authorized for procurement. In addition, in generic relationships, a code 1 item is related to a code 2 item.
Defense Supply Center Richmond, Richmond, VA 23297-5000
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
An item which, as a result of a formal item reduction study, is accepted as not authorized for procurement.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
SE |
San Antonio Air Logistics Center, Kelly AFB, TX 78241-5000
No Variation. NMFC and UFCC Match.
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
CXCW | Conductor Form | STRANDED SINGLE CONDUCTOR |
MATT | Material | COPPER CORE CONDUCTOR SINGLE CONDUCTOR |
MATT | Material | PLASTIC POLYVINYL CHLORIDE 1ST POSITION PRIMARY INSULATION SINGLE CONDUCTOR |
MATT | Material | GLASS FIBER 2ND POSITION SECONDARY INSULATION SINGLE CONDUCTOR |
MATT | Material | PLASTIC POLYAMIDE 3RD POSITION JACKET SINGLE CONDUCTOR |
SFTT | Surface Treatment | TIN CORE CONDUCTOR THIRD GROUP |
CXDC | Round Conductor Size | 4 AWG SINGLE CONDUCTOR |
BLNZ | Strand Quantity Per Conductor | 133 SINGLE CONDUCTOR |
CXDG | Strand Awg Size Per Conductor | 25 SINGLE CONDUCTOR |
HUES | Color | WHITE CORE CONDUCTOR SINGLE CONDUCTOR |
CXFK | Voltage Rating | 600.0 MAXIMUM ROOT MEAN SQUARE (RMS) OPERATING VOLTAGE SINGLE CONDUCTOR |
AAGR | Cross-Sectional Shape Style | ROUND |
ADVL | Cross Section Outside Diameter | 0.355 INCHES NOMINAL |
AKRZ | Termination Type | LUG TERMINAL W/MOUNTING HOLE BOTH ENDS SINGLE CONDUCTOR |
CXFM | Terminal Lug Aperture Size | 0.250 INCHES 1ST END SINGLE CONDUCTOR |
CXFM | Terminal Lug Aperture Size | 0.312 INCHES 2ND END SINGLE CONDUCTOR |
CXGN | Terminal Commercial And Government Entity Code | 96906 BOTH ENDS SINGLE CONDUCTOR |
AXBQ | Lead Overall Length | 47.062 INCHES NOMINAL |