6150-00-291-6824

CABLE ASSEMBLY,SPECIAL PURPOSE,ELECTRICAL


6150-00-291-6824 (6150002916824, 002916824)
Part Number (1 listing): B542001794-1
Summary

FSG 61 / FSC 6150

DEMIL: A

DEMIL INT:

HMIC: N

Date Created: 14 Sep 1973

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 6150-00-291-6824 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
B542001794-13 - Design Control Reference2 - Production ItemKEARFOTT CORPORATION  88818    CAGE 88818  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.


FLIS - SEG A - IDENTIFICATION | NSN 6150-00-291-6824 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
616150002916824A077A000782XM6ANS014 Sep 1973
Code Definitions

61

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electric Wire, and Power and Distribution Equipment

6150

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Miscellaneous Electric Power and Distribution Equipment

002916824

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 6150-00-291-6824

A077A0

Federal Item Identification Guide (FIIG_4065)

00782

Item Naming Code (INC_4080)

14 Sep 1973

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

M

Type of Item Identification (TYP_II_4820)


Partial Descriptive - Reference Item Identification (Type 1A Concept)

6

Reference / Partial Descriptive Method Reason Code (RPDMRC_4765)


An approved item name and FIIG may exist, but it has previously been established and documented that industry refuses to provide the technical data sufficient for preparation on a full descriptive method item identification based on policy, restricted or proprietary data rights, nonexistence of technical data, etc.

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

S

Precious Metals Indicator Code (PMIC_0802)


Item contains silver.

0

ADPE Identification Code (ADPEC_0801)


Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)


FLIS - SEG B - MOE RULE DATA | NSN 6150-00-291-6824 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
YB011 May 1997
Code Definitions

FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 6150-00-291-6824 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
2GP030 Sep 1974
Code Definitions

2

Item Standardization Code (ISC_2650)


An item authorized for procurement which has been included in an item reduction study and which initially does not replace an item not authorized for procurement. In addition, in generic relationships, a code 2 item is related to a code 1 item.

GP

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


Naval Inventory Control Point, Philadelphia, PA 19111-5098

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

30 Sep 1974

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 6150-00-291-6824 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
SE743ZZAVZP061130X34350CABLE-ASSEMBLY1
Code Definitions

SE

Originating Activity Code (ORIG_ACTY_CD_4210)


San Antonio Air Logistics Center, Kelly AFB, TX 78241-5000

743

Water Commodity Code (WRT_CMDTY_CD_9275)


Electrical Cable

Z

Type Cargo Code (TYPE_CGO_CD_9260)


No special type of cargo code applicable

Z

Special Handling Code (SP_HDLG_CD_9240)


No special handling required. Heavy Lift (HL). Five short tons (10,000 lbs) or more. Applies to any piece, package, or palletized, unitized or containerized unit (excluding SEAVAN/MILVAN). Outsized Dimensions. Dimensions of any piece, package, or palletized, unitized or containerized unit (excluding SEAVAN/MILVAN, CONEXs, and POVs) which exceed six (6) feet in any dimension.

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

V

Air Commodity Code (AIR_CMTY_HDLG_9215)


Vehicles, machinery, shop and warehouse equipment and supplies, including special tools and equipment, ground servicing and special purpose vehicles, marine equipment and supplies, repair and maintenance parts for the above.

Z

Air Special Handling Code (AIR_CMTY_HDLG_9215)


No special handling required.

P

Less Than Truckload (CLAS_RTNG_CD_2770)


77.5

061130

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

X

NMFC Sub Item Number (SUB_ITM_NBR_0861)

34350

Uniform Freight Classification (UFC_CD_MODF_3040)

CABLE-ASSEMBLY

Freight Description (FRT_DESC_4020)

1 Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


A Variation Exists. NMFC and UFCC Do Not Match. Activity needs to determine which of these descriptions apply.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 6150-00-291-6824 Submit RFQ
MRCDecoded RequirementClear Text Reply
AMQNConductor Quantity43
CXDQConductor Arrangement And Quantity43 SINGLES
CXCWConductor FormSTRANDED ALL CONDUCTORS
ZZZVFsc Application DataTEST SET,CONTROL,SPECIALLY DESIGNED,ACFT
MATTMaterialCOPPER 1ST POSITION CONDUCTOR ALL CONDUCTORS
MATTMaterialPLASTIC POLYALKENE 1ST POSITION PRIMARY INSULATION ALL CONDUCTORS
MATTMaterialPLASTIC POLYVINYL CHLORIDE 1ST POSITION SLEEVE CABLE OR RUBBER CHLOROPRENE CLASS CR 1ST POSITION SLEEVE CABLE
MATTMaterialPLASTIC POLYVINYLIDENE FLUORIDE 2ND POSITION JACKET ALL CONDUCTORS
MATTMaterialTIN 2ND POSITION CONDUCTOR ALL CONDUCTORS
CXDCRound Conductor Size22 AWG ALL CONDUCTORS
AAJUOverall Length26.000 INCHES
CXDGStrand Awg Size Per Conductor34 ALL CONDUCTORS
BLNZStrand Quantity Per Conductor19 ALL CONDUCTORS
STYLStyle DesignatorINTERNAL ANGLE AND INTERNAL STRAIGHT CONNECTOR
SFTTSurface TreatmentSILVER CORE CONDUCTOR ALL CONDUCTORS
CXGNTerminal Commercial And Government Entity Code02660 1ST END ALL CONDUCTORS
CXGNTerminal Commercial And Government Entity Code02660 BOTH ENDS ALL CONDUCTORS
CXGGTerminal Manufacturer Identifying Reference Number57-30500 2ND END ALL CONDUCTORS
CXGGTerminal Manufacturer Identifying Reference Number204748-1 1ST END ALL CONDUCTORS
AKRZTermination TypeCONNECTOR PLUG BOTH ENDS ALL CONDUCTORS


Back to Top