Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
2846703-1 | 3 - Design Control Reference | 2 - Production Item | NAVAIR AND NAVSEA MANAGED | 10001 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
61 | 6150 | 003701253 | A077A0 | 04581 | X | K | A | N | U | 5 Mar 1969 |
Electric Wire, and Power and Distribution Equipment
Miscellaneous Electric Power and Distribution Equipment
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Full Descriptive - Reference Item Identification
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.
Precious Metal Content is unknown.
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ZE01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
N9BG | N9GD | 1 | G | Z | HD | HD | 1 May 2006 |
Suitable for competitive acquisition. Potential sources shall include dealers/distributors. If sources are limited to the prime contractor and a subcontractor, a competitive code shall not be assigned unless both sources are expected to compete independently for contracts for the part.
The Government has unlimited rights to the technical data, and the data package is complete. Valid AMCs: 1 and 2.
Integrated Management: Relinquishment of Service management of an item in designated commodity oriented Federal Supply Classes to the IMM (FSC manager) for management.
Naval Inventory Control Point, Mechanicsburg, PA 17055-0788
Naval Inventory Control Point, Mechanicsburg, PA 17055-0788
RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
3 | 3 | 2 | 1 | HD | D | 2846703-1 | 10001 | ![]() |
Number format is unknown. (Coded RNFC 3 by the Defense Logistics Information Service upon implementation of FLIS.)
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
The reference number is represented by a drawing and the drawing was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the drawing upon request.
Naval Inventory Control Point, Mechanicsburg, PA 17055-0788
Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
1 | CX | 0 | 3 | CX | 1 | 12 Mar 1978 | 6150003701217 | 14 Mar 1978 |
1 | CX | 0 | 3 | CX | 1 | 14 Mar 1984 | 6150003701256 | 14 Mar 1978 |
An item authorized for procurement as a result of a formal item reduction study and accepted as a replacement for one or more items not authorized for procurement. In addition, in generic relationships, a code 1 item is related to a code 2 item.
Defense Supply Center Richmond, Richmond, VA 23297-5000
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
An item which, as a result of a formal item reduction study, is accepted as not authorized for procurement.
Represents an item for which a U.S. activity proposed cancelled-invalid or cancelled-use action or that the NIIN Status Code be changed to 9, and one or more NATO/FC did not concur in the proposal. See volume 4, chapter 4.9.Item is restricted to North Atlantic Treaty Organization/foreign country (NATO/FC) use only.Represents an item for which a U.S. activity proposed cancelled-invalid or cancelled-use action or that the NIIN Status Code be changed to 9, and one or more NATO/FC did not concur in the proposal. Item is restricted to North Atlantic Treaty Organization/foreign country (NATO/FC) use only.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
HD | 743 | Z | 9 | A | H | Z | J | 062360 | X | 34890 | LEADS-LEAD-WIRES-ELEC-ARTICLE-ETC |
Naval Inventory Control Point, Mechanicsburg, PA 17055-0788
Electrical Cable
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
No special handling required.
100.2
No Variation. NMFC and UFCC Match.
Defense Logistics Agency, Enterprise Business Systems
NOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition.
Unclassified
1
Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.
TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.
Department of the Navy
Defense Logistics Agency
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
HUES | Color | BLACK CORE CONDUCTOR SINGLE CONDUCTOR |
CXCW | Conductor Form | STRANDED SINGLE CONDUCTOR |
ADVL | Cross Section Outside Diameter | 0.128 INCHES NOMINAL |
AAGR | Cross-Sectional Shape Style | ROUND |
MATT | Material | COPPER CORE CONDUCTOR SINGLE CONDUCTOR |
MATT | Material | PLASTIC 1ST POSITION PRIMARY INSULATION SINGLE CONDUCTOR |
AXBQ | Lead Overall Length | 61.000 INCHES NOMINAL |
CXDC | Round Conductor Size | 12 AWG SINGLE CONDUCTOR |
FEAT | Special Features | TERMINAL END WRAPPED WITH RED INSULATION TAPE |
CXFK | Voltage Rating | 600.0 AC MAXIMUM RATED WORKING VOLTAGE SINGLE CONDUCTOR |
CXDG | Strand Awg Size Per Conductor | 25 SINGLE CONDUCTOR |
BLNZ | Strand Quantity Per Conductor | 19 SINGLE CONDUCTOR |
SFTT | Surface Treatment | TIN CORE CONDUCTOR THIRD GROUP |
CXGN | Terminal Commercial And Government Entity Code | 96906 1ST END SINGLE CONDUCTOR |
CXFM | Terminal Lug Aperture Size | 0.196 INCHES 1ST END SINGLE CONDUCTOR |
CXGG | Terminal Manufacturer Identifying Reference Number | MS20659-5 1ST END SINGLE CONDUCTOR |