Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
J-C-1270 | 4 - Non-Definitive Specification or Standard Document | 1 - Incomplete Part Number | FEDERAL SPECIFICATIONS | 81348 | |
J-C-1270 ST3CL2SE2GRHKD1 | 5 - Replaced / Discontinued | 1 - Incomplete Part Number | GENERAL SERVICES ADMINISTRATION | 80244 |
Non-Definitive U.S. Government Specification or Standard Reference. Any Government specification or standard reference other than those indicated in code 2 as definitive references. This code shall be used for non-definitive Government specifications and standard references and non-definitive part numbers, type designators, and style numbers included therein which are coded with RNVC 1.
Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.
A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
61 | 6150 | 004856149 | A077A0 | 00485 | X | 1 | A | N | A | 19 Jun 1974 |
Electric Wire, and Power and Distribution Equipment
Miscellaneous Electric Power and Distribution Equipment
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Full Descriptive Item Identification
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.
Item does not contain Precious Metal.
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
G751 | 1 | G | 1 Apr 1991 | |||||||||||||||||||||||||||
G801 | 0 | 0 | 1 Apr 1991 | |||||||||||||||||||||||||||
G861 | 0 | 0 | 1 Apr 1991 | |||||||||||||||||||||||||||
G881 | 0 | 0 | 1 Apr 1991 | |||||||||||||||||||||||||||
G901 | 0 | 0 | 1 Apr 1991 | |||||||||||||||||||||||||||
MC14 | 1 | G | Z | PA | 1 Apr 1991 | |||||||||||||||||||||||||
N9QG | 1 | G | Z | GH | GT | JS | JN | JB | HX | HS | HE | HD | JV | 1 Apr 1991 | ||||||||||||||||
A190 | 1 | G | Z | CD | AJ | BF | BD | AM | 1 Apr 1991 | |||||||||||||||||||||
C014 | 1 | G | 1 Apr 1991 | |||||||||||||||||||||||||||
ZG01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZN01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
YB01 | 1 May 1997 | |||||||||||||||||||||||||||||
B750 | B480 | 0 | 0 | 1 Dec 1999 | ||||||||||||||||||||||||||
FXGS | FAGS | 1 | G | Z | SX | TT | 1 Jun 2000 | |||||||||||||||||||||||
ZH01 | 1 May 2003 | |||||||||||||||||||||||||||||
ZK01 | 1 Jan 2005 | |||||||||||||||||||||||||||||
ZW01 | 1 Dec 2005 | |||||||||||||||||||||||||||||
ZA01 | 1 Nov 2013 | |||||||||||||||||||||||||||||
ZS01 | 1 May 2015 |
Suitable for competitive acquisition. Potential sources shall include dealers/distributors. If sources are limited to the prime contractor and a subcontractor, a competitive code shall not be assigned unless both sources are expected to compete independently for contracts for the part.
The Government has unlimited rights to the technical data, and the data package is complete. Valid AMCs: 1 and 2.
Not Established
Integrated Management: Relinquishment of Service management of an item in designated commodity oriented Federal Supply Classes to the IMM (FSC manager) for management.
Marine Corps Logistics Base, Albany, GA 31704-1128
Naval Inventory Control Point, Mechanicsburg, PA 17055-0788
U.S. Army War Reserve Command, New Cumberland, PA 17070-5008
Oklahoma City Air Logistics Center, Tinker AFB, OK 73145-3043
Naval ICP, Mechanicsburg, PA 17055-0788
Naval Facilities Expeditionary Logistics Center, Port Hueneme, CA 93043
Navy ICP, Mechanicsburg, PA 17055-0788
HE
Naval Air Engineering Center, Lakehurst, NJ 08733
Naval Inventory Control Point, Mechanicsburg, PA 17055-0788
Strategic Systems Programs C/O Tracor Sys Engineering Rockville, MD 20850-1160
U.S. Army Soldier's Biological and Chemical, Command, Natick, MA 01760
U.S. Army Armament and Chemical Acquisition and, Logistics Activity, Rock Island, IL 61299-6000
U.S. Army Aviation and Missile Command, Redstone Arsenal, AL 35898-5230
U.S. Army Medical Materiel Agency, Frederick, MD 21701-5001
Air Force Medical Logistics Office, Fredrick, MD 21701-5006
RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
4 | 1 | 3 | 75 | J-C-1270 | 81348 | |||||||
5 | 1 | 3 | 75 | J-C-1270 ST3CL2SE2GRHKD1 | 80244 |
Non-Definitive U.S. Government Specification or Standard Reference. Any Government specification or standard reference other than those indicated in code 2 as definitive references. This code shall be used for non-definitive Government specifications and standard references and non-definitive part numbers, type designators, and style numbers included therein which are coded with RNVC 1.
A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.
The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the technical documentation upon request.
GSA, FSS/FCSC Washington, DC 20406
Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
1 | CX | 0 | 3 | CX | 1 | 17 Feb 1976 | 6150001440092 | 17 Feb 1976 |
An item authorized for procurement as a result of a formal item reduction study and accepted as a replacement for one or more items not authorized for procurement. In addition, in generic relationships, a code 1 item is related to a code 2 item.
Defense Supply Center Richmond, Richmond, VA 23297-5000
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
An item which, as a result of a formal item reduction study, is accepted as not authorized for procurement.
Represents an item for which a U.S. activity proposed cancelled-invalid or cancelled-use action or that the NIIN Status Code be changed to 9, and one or more NATO/FC did not concur in the proposal. See volume 4, chapter 4.9.Item is restricted to North Atlantic Treaty Organization/foreign country (NATO/FC) use only.Represents an item for which a U.S. activity proposed cancelled-invalid or cancelled-use action or that the NIIN Status Code be changed to 9, and one or more NATO/FC did not concur in the proposal. Item is restricted to North Atlantic Treaty Organization/foreign country (NATO/FC) use only.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
CX | 743 | Z | 9 | A | H | Z | P | 061130 | X | 34350 | CABLE-ASSEMBLY |
Defense Supply Center Richmond, Richmond, VA 23297-5000
Electrical Cable
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
No special handling required.
77.5
No Variation. NMFC and UFCC Match.
Unit Price | MOE | SOS | AAC | CIIC | QUP | Reparability | UI | SLC |
---|---|---|---|---|---|---|---|---|
DA | GSA | H | U | 0 | Z | EA | 0 | |
DF | GSA | H | U | 0 | N | EA | 0 | |
DM | GSA | H | U | 0 | Z | EA | 0 | |
DN | GSA | H | U | 0 | EA | 0 | ||
GP | GSA | H | U | 0 | EA | 0 | ||
TG | GSA | H | U | 0 | EA | 0 |
General Services Administration, Washington, D.C. 20406
DIRECT DELIVERY UNDER A CENTRAL CONTRACT # (VENDOR STOCKED) Issue, transfer or shipment is not subject to specialized controls other than those imposed by IMM/Service/Agency supply policy. 1. The item is centrally managed and procured. 2. Normal issue is by direct shipment from the vendor to the user at the order of the ICP or IMM. However, orders may be shipped from stock by ICP or IMM distribution facilities when the vendor's minimum order quantity is not met, or when stocks are being drawn down. 3. Requisitions and fund citations will be submitted in accordance with IMM/Service/Agency Requisitioning Procedures. 4. Generally delivery will be made within applicable Service/Agency guidelines addressing customer required timeframe.
Unclassified
No QUP
ARMY: This is a nonreparable item. If condemned or economically unserviceable, then dispose at the level authorized replace the item; MARINE CORPS: Nonreparable item. When unserviceable, condemn and dispose at the level indicated by the first digit of the maintenance code; NAVY: Special Program Consumables
Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.
TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.
AIR FORCE ERRC XB3: Stock Fund (Except Munitions); DLA: This item has been reviewed and a determination made that the item cannot or should not be restored to a serviceable condition from an unserviceable condition; NAVY: 1I cog not stocked print on demand flat forms
Department of the Army
Department of the Air Force
U.S. Marine Corps
Department of the Navy
U.S. Coast Guard
General Services Administration
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
AWTB | Accessory Wire Type And Quantity | 1 GROUND |
CXDQ | Conductor Arrangement And Quantity | 1 TWISTED PAIR |
CXCW | Conductor Form | STRANDED ALL CONDUCTORS |
ADVL | Cross Section Outside Diameter | 0.550 INCHES NOMINAL |
AAGR | Cross-Sectional Shape Style | ROUND |
AMQN | Conductor Quantity | 2 |
MATT | Material | COPPER CORE CONDUCTOR ALL CONDUCTORS |
MATT | Material | PLASTIC 1ST POSITION PRIMARY INSULATION ALL CONDUCTORS |
MATT | Material | PLASTIC 1ST POSITION JACKET CABLE |
ZZZT | Nondefinitive Spec/Std Data | 3 STYLE AND 2 CLASS AND 2 SERIES AND H GRADE AND 1 KIND |
CXDC | Round Conductor Size | 14 AWG ALL CONDUCTORS |
AAJU | Overall Length | 25.000 FEET |
CXFK | Voltage Rating | 600.0 AC MAXIMUM RATED WORKING VOLTAGE ALL CONDUCTORS |
CXDG | Strand Awg Size Per Conductor | 30 ALL CONDUCTORS |
BLNZ | Strand Quantity Per Conductor | 41 ALL CONDUCTORS |
STYL | Style Designator | INTERNAL AND EXTERNAL CONNECTOR |
ABJH | Temp Rating | 60.0 DEG CELSIUS |
CXGN | Terminal Commercial And Government Entity Code | 81705 2ND END ALL CONDUCTORS |
CXGN | Terminal Commercial And Government Entity Code | 81705 1ST END ALL CONDUCTORS |
CXGG | Terminal Manufacturer Identifying Reference Number | WD1 FIG. 5-15P 1ST END ALL CONDUCTORS |
CXGG | Terminal Manufacturer Identifying Reference Number | WD1 FIG. 5-15P 2ND END ALL CONDUCTORS |
AKRZ | Termination Type | CONNECTOR PLUG 2ND END ALL CONDUCTORS |
AKRZ | Termination Type | CONNECTOR RECEPTACLE 1ST END ALL CONDUCTORS |