Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
MS25083-2AB11 | 2 - Definitive Specification or Standard Document | 2 - Production Item | MILITARY STANDARDS | 96906 | ![]() |
Definitive Government Specification or Standard Designator Reference. A part number, style number, or type designator included in or developed in accordance with a Government specification or standard which has the effect of fully identifying an item of supply. This code shall also be used for a Government specification or standard which, although not including part numbers, style numbers, or type designators, covers a single item of upply. These reference numbers may be coded with Reference Number Variation Code (RNVC) 1 in accordance with volume 2, paragraph 2.9.2.n.(4).
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
61 | 6150 | 006421323 | A077A0 | 04581 | X | 1 | A | N | U | 29 Jun 1967 |
Electric Wire, and Power and Distribution Equipment
Miscellaneous Electric Power and Distribution Equipment
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Full Descriptive Item Identification
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.
Precious Metal Content is unknown.
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ZH01 | 1 Mar 1998 | |||||||||||||||||||||||||||||
ZG01 | 1 Feb 2005 |
RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
3 | 2 | 2 | 4 | SE | D | MS25083-2AB11 | 96906 | ![]() |
Number format is unknown. (Coded RNFC 3 by the Defense Logistics Information Service upon implementation of FLIS.)
Definitive Government Specification or Standard Designator Reference. A part number, style number, or type designator included in or developed in accordance with a Government specification or standard which has the effect of fully identifying an item of supply. This code shall also be used for a Government specification or standard which, although not including part numbers, style numbers, or type designators, covers a single item of upply. These reference numbers may be coded with Reference Number Variation Code (RNVC) 1 in accordance with volume 2, paragraph 2.9.2.n.(4).
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the technical documentation.
San Antonio Air Logistics Center, Kelly AFB, TX 78241-5000
Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
3 | CX | 1 | 1 | CX | 0 | 14 Mar 1978 | 6150004261969 | 12 Mar 1978 |
An item which, as a result of a formal item reduction study, is accepted as not authorized for procurement.
Defense Supply Center Richmond, Richmond, VA 23297-5000
Represents an item for which a U.S. activity proposed cancelled-invalid or cancelled-use action or that the NIIN Status Code be changed to 9, and one or more NATO/FC did not concur in the proposal. See volume 4, chapter 4.9.Item is restricted to North Atlantic Treaty Organization/foreign country (NATO/FC) use only.Represents an item for which a U.S. activity proposed cancelled-invalid or cancelled-use action or that the NIIN Status Code be changed to 9, and one or more NATO/FC did not concur in the proposal. Item is restricted to North Atlantic Treaty Organization/foreign country (NATO/FC) use only.
An item authorized for procurement as a result of a formal item reduction study and accepted as a replacement for one or more items not authorized for procurement. In addition, in generic relationships, a code 1 item is related to a code 2 item.
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
SG | J | 658 | Z | 5 | A | H | Y | J | 062360 | X | 34890 | LEADS-LEAD-WIRES-ELEC-ARTICLE-ETC | 1 |
403 SCMS/GUED, 5215 Thurlow St, Suite 5, Bldg 70C Wright-Patterson AFB OH 45433
100.2
Electical Appliances, Small
No special type of cargo code applicable
Protected (Pilferable)
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Protected cargo, other than above, including sensitive cargo requiring hand-to-hand receipt and/or security precautions.
A Variation Exists. NMFC and UFCC Do Not Match. Activity needs to determine which of these descriptions apply.
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
CXCW | Conductor Form | STRANDED SINGLE CONDUCTOR |
ADVL | Cross Section Outside Diameter | 0.080 INCHES NOMINAL |
AAGR | Cross-Sectional Shape Style | ROUND |
MDCL | Material Document And Classification | QQ-W-343,SOFT FED STD ALL MATERIAL RESPONSES CORE CONDUCTOR SINGLE CONDUCTOR |
MATT | Material | COPPER CORE CONDUCTOR SINGLE CONDUCTOR |
AXBQ | Lead Overall Length | 11.000 INCHES MINIMUM AND 11.250 INCHES MAXIMUM |
CXHH | Lead Pull Strength | 110.0 POUNDS |
CXDC | Round Conductor Size | 12 AWG SINGLE CONDUCTOR |
CXDG | Strand Awg Size Per Conductor | 36 SINGLE CONDUCTOR |
BLNZ | Strand Quantity Per Conductor | 259 SINGLE CONDUCTOR |
SFTT | Surface Treatment | TIN CORE CONDUCTOR THIRD GROUP |
CXGN | Terminal Commercial And Government Entity Code | 96906 BOTH ENDS SINGLE CONDUCTOR |
CXFM | Terminal Lug Aperture Size | 0.143 INCHES 1ST END SINGLE CONDUCTOR |
CXFM | Terminal Lug Aperture Size | 0.196 INCHES 2ND END SINGLE CONDUCTOR |
CXGG | Terminal Manufacturer Identifying Reference Number | MS25036-111 1ST END SINGLE CONDUCTOR |
CXGG | Terminal Manufacturer Identifying Reference Number | MS25036-112 2ND END SINGLE CONDUCTOR |
AKRZ | Termination Type | LUG TERMINAL W/MOUNTING HOLE BOTH ENDS SINGLE CONDUCTOR |
TEST | Test Data Document | 96906-MS25083 STANDARD (INCLUDES INDUSTRY OR ASSOCIATION STANDARDS, INDIVIDUAL MANUFACTUREER STANDARDS, ETC.). |