6150-00-946-6954

CABLE ASSEMBLY,POWER,ELECTRICAL


6150-00-946-6954 (6150009466954, 009466954)
Part Numbers (2 listings): 719-40 | 928323-3 |
Summary

FSG 61 / FSC 6150

DEMIL: A

DEMIL INT:

HMIC: N

Date Created: 21 Mar 1966

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 6150-00-946-6954 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
719-403 - Design Control Reference2 - Production ItemVIKING ELECTRONICS, INC.  81861      
928323-35 - Replaced / Discontinued2 - Production ItemVIKING ELECTRONICS, INC.  81861      
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

5 - Replaced / Discontinued

Reference Number Category Code (DRN_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.


FLIS - SEG A - IDENTIFICATION | NSN 6150-00-946-6954 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
616150009466954A077A000485XM9ANU21 Mar 1966
Code Definitions

61

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electric Wire, and Power and Distribution Equipment

6150

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Miscellaneous Electric Power and Distribution Equipment

009466954

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 6150-00-946-6954

A077A0

Federal Item Identification Guide (FIIG_4065)

00485

Item Naming Code (INC_4080)

21 Mar 1966

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

M

Type of Item Identification (TYP_II_4820)


Partial Descriptive - Reference Item Identification (Type 1A Concept)

9

Reference / Partial Descriptive Method Reason Code (RPDMRC_4765)


A Defense Logistics Information Service-generated code for items lacking but requiring an RPDMRC (i.e., through mass FIIG revision change an item may be downgraded from a type 1 to a reference or partial descriptive method item identification).

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

U

Precious Metals Indicator Code (PMIC_0802)


Precious Metal Content is unknown.


FLIS - SEG B - MOE RULE DATA | NSN 6150-00-946-6954 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
ZC011 Apr 1991
ZR011 Apr 1991
ZG011 Jan 2015
Code Definitions

FLIS - SEG C - REFERENCE NUMBER | NSN 6150-00-946-6954 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
33229ZD719-40  81861  
Code Definitions

3

Reference Number Format Code (RNFC_2920)


Number format is unknown. (Coded RNFC 3 by the Defense Logistics Information Service upon implementation of FLIS.)

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

2

Document Availability Code (DAC_2640)


The reference number is represented by a drawing and the drawing was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the drawing.

9Z

Reference Number Action Activity Code (RNAAC_2900)


DLIS-K, Battle Creek, MI 49037-3084

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 6150-00-946-6954 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
2D4028 Jul 1970
Code Definitions

2

Item Standardization Code (ISC_2650)


An item authorized for procurement which has been included in an item reduction study and which initially does not replace an item not authorized for procurement. In addition, in generic relationships, a code 2 item is related to a code 1 item.

D4

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


U.S. Army Belvoir Research, Development and, Engineering Center, Fort Belvoir, VA 22060-5606

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

28 Jul 1970

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 6150-00-946-6954 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
ZG
Code Definitions

ZG

Originating Activity Code (ORIG_ACTY_CD_4210)


Germany

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 6150-00-946-6954 Submit RFQ
MRCDecoded RequirementClear Text Reply
CXCWConductor FormSTRANDED ALL CONDUCTORS
AMQNConductor Quantity6
MATTMaterialRUBBER NATURAL 1ST POSITION JACKET CABLE
CXDCRound Conductor Size10 AWG 5TH CONDUCTOR
CXDCRound Conductor Size10 AWG 6TH CONDUCTOR
CXDCRound Conductor Size2 AWG 1ST CONDUCTOR
CXDCRound Conductor Size2 AWG 2ND CONDUCTOR
CXDCRound Conductor Size2 AWG 3RD CONDUCTOR
CXDCRound Conductor Size2 AWG 4TH CONDUCTOR
AAJUOverall Length40.000 FEET
CXFKVoltage Rating600.0 AC MAXIMUM RATED WORKING VOLTAGE ALL CONDUCTORS
CXGNTerminal Commercial And Government Entity Code81861 1ST END ALL CONDUCTORS
CXGNTerminal Commercial And Government Entity Code81861 2ND END ALL CONDUCTORS
CXGGTerminal Manufacturer Identifying Reference Number3150-0000-0000 2ND END ALL CONDUCTORS
CXGGTerminal Manufacturer Identifying Reference Number1682-0000-0000 1ST END ALL CONDUCTORS
AKRZTermination TypeCONNECTOR PLUG 2ND END ALL CONDUCTORS
AKRZTermination TypeCONNECTOR RECEPTACLE 1ST END ALL CONDUCTORS


Back to Top