| Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
|---|---|---|---|---|---|
| 990D948G01 | 3 - Design Control Reference | 2 - Production Item | NORTHROP GRUMMAN SYSTEMS CORPORATION | 18323 | |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
| FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 61 | 6150 | 010057604 | A077A0 | 00485 | X | K | A | N | S | 4 Jul 1975 |
Electric Wire, and Power and Distribution Equipment
Miscellaneous Electric Power and Distribution Equipment
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Full Descriptive - Reference Item Identification
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.
Item contains silver.
| MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| ZW01 | 1 Dec 1995 | |||||||||||||||||||||||||||||
| RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1 | 3 | 2 | 2 | SB | D | 990D948G01 | 18323 | | ||||
Number is formatted as configured on the originating document with the exception of the modification required in volume 2, chapter 2.9.Number is formatted as configured on the originating document with the exception of the modification required in volume 2, chapter 2.9 .
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
The reference number is represented by a drawing and the drawing was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the drawing.
645 MSSQ/MSIAPCS, Wright-Patterson AFB, OH 45433-5603
Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.
| ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
|---|---|---|---|---|---|---|---|---|
| 6 | TU | 0 | 20 Dec 1983 |
An item authorized for procurement that is in a specific Federal Supply Class (FSC) or item name grouping consisting primarily of items which are one-of-a-kind; therefore, little or no potential exists for elimination of items through formal item reduction studies.
AF Cataloging Agent DLIS-K, Battle Creek, MI 49037-3094
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
| Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| SE | 743 | Z | Z | A | V | Z | P | 061130 | X | 34350 | CABLE-ASSEMBLY | 1 |
San Antonio Air Logistics Center, Kelly AFB, TX 78241-5000
Electrical Cable
No special type of cargo code applicable
No special handling required. Heavy Lift (HL). Five short tons (10,000 lbs) or more. Applies to any piece, package, or palletized, unitized or containerized unit (excluding SEAVAN/MILVAN). Outsized Dimensions. Dimensions of any piece, package, or palletized, unitized or containerized unit (excluding SEAVAN/MILVAN, CONEXs, and POVs) which exceed six (6) feet in any dimension.
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Vehicles, machinery, shop and warehouse equipment and supplies, including special tools and equipment, ground servicing and special purpose vehicles, marine equipment and supplies, repair and maintenance parts for the above.
No special handling required.
77.5
A Variation Exists. NMFC and UFCC Do Not Match. Activity needs to determine which of these descriptions apply.
| MRC | Decoded Requirement | Clear Text Reply |
|---|---|---|
| CXCW | Conductor Form | STRANDED ALL CONDUCTORS |
| CXDQ | Conductor Arrangement And Quantity | 1 SINGLES AND 2 TWISTED PAIR |
| ADVL | Cross Section Outside Diameter | 0.500 INCHES NOMINAL |
| AAGR | Cross-Sectional Shape Style | ROUND |
| AMQN | Conductor Quantity | 5 |
| MDCL | Material Document And Classification | QQ-W-343,SOFT FED SPEC SINGLE MATERIAL RESPONSE CORE CONDUCTOR ALL CONDUCTORS |
| MATT | Material | COPPER CORE CONDUCTOR ALL CONDUCTORS |
| MATT | Material | PLASTIC POLYTETRAFLUOROETHYLENE 1ST POSITION PRIMARY INSULATION ALL CONDUCTORS |
| CXDC | Round Conductor Size | 12 AWG ALL CONDUCTORS |
| FEAT | Special Features | 1 COVER |
| AAJU | Overall Length | 112.000 INCHES |
| CXFK | Voltage Rating | 600.0 MAXIMUM ROOT MEAN SQUARE (RMS) OPERATING VOLTAGE ALL CONDUCTORS |
| CXDG | Strand Awg Size Per Conductor | 25 ALL CONDUCTORS |
| BLNZ | Strand Quantity Per Conductor | 19 ALL CONDUCTORS |
| STYL | Style Designator | INTERNAL ANGLE AND INTERNAL STRAIGHT CONNECTOR |
| STDC | Surface Treatment Document And Classification | ASTM B298-58T ASSN STD SINGLE TREATMENT RESPONSE CORE CONDUCTOR ALL CONDUCTORS |
| SFTT | Surface Treatment | SILVER CORE CONDUCTOR ALL CONDUCTORS |
| ABJH | Temp Rating | 200.0 DEG CELSIUS |
| CXGN | Terminal Commercial And Government Entity Code | 96906 1ST END ALL CONDUCTORS |
| CXGN | Terminal Commercial And Government Entity Code | 96906 2ND END ALL CONDUCTORS |
| CXGG | Terminal Manufacturer Identifying Reference Number | MS3102R24-2P 1ST END ALL CONDUCTORS |
| CXGG | Terminal Manufacturer Identifying Reference Number | MS3106A24-2SW 2ND END ALL CONDUCTORS |
| AKRZ | Termination Type | CONNECTOR PLUG BOTH ENDS ALL CONDUCTORS |