Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
2356242-1 | 3 - Design Control Reference | 2 - Production Item | RAYTHEON COMPANY | 96214 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
61 | 6150 | 011087189 | A077A0 | 00485 | X | 1 | B | N | A | 2 | 5 Mar 1981 |
Electric Wire, and Power and Distribution Equipment
Miscellaneous Electric Power and Distribution Equipment
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Full Descriptive Item Identification
MLI (Non-Significant Military Equipment – Non-SME) — Demilitarization not required — Trade Security Controls (TSCs) required at disposition.
Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.
Item does not contain Precious Metal.
Digital CPUs, ADP Central Processing Units for Computers. Represents only CPUs that accept information represented by digital impulses. Specifically, a device capable of performing sequences of arithmetic and logic operations (a program) not only on data but also on the program which is contained in its internal memory (storage) without intervention of an operator. NOTE: Digital refers to the representation of discrete numbers, symbols, and alphabetic characters by a predetermined, coded combination of electrical impulses. Excludes CPUs that have both analog and digital capability. (See code 3)
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ZU01 | 1 May 2008 | |||||||||||||||||||||||||||||
FMSU | FUU4 | 1 | G | D | 1 Dec 2009 | |||||||||||||||||||||||||
ZF01 | 1 Aug 2010 |
Suitable for competitive acquisition. Potential sources shall include dealers/distributors. If sources are limited to the prime contractor and a subcontractor, a competitive code shall not be assigned unless both sources are expected to compete independently for contracts for the part.
The Government has unlimited rights to the technical data, and the data package is complete. Valid AMCs: 1 and 2.
Major End Items of Equipment: Items of such importance to the operations readiness of operating units that they are subject to continuing centralized individual item management and asset control throughout all command and support echelons.
RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
4 | 3 | 2 | 5 | SB | D | 2356242-1 | 96214 | ![]() |
Number is totally in-the-clear (without modification) as originally configured by the manufacturer, design control activity, or supplier.
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
The reference number is represented by a drawing, but the drawing was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.
645 MSSQ/MSIAPCS, Wright-Patterson AFB, OH 45433-5603
Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
5 | 97 | 0 | 5 Mar 1981 |
An item authorized for procurement that has not yet been subject to item standardization.
DLIS-LFF, Battle Creek, MI 49037-3084
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
SU | Q | 743 | 3 | 9 | A | H | Z | P | 061130 | X | 34350 | CABLE-ASSEMBLY | 1 |
Ogden Air Logistics Center, Hill AFB, UT 84056-5609
70
Electrical Cable
Electrostatic Sensitive Device (ESD), subject to damage caused by electrostatic discharge. (See DoD 4500.32-R, Volume 1, Appendix A, Section I for additional information on ESD devices).
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
No special handling required.
77.5
A Variation Exists. NMFC and UFCC Do Not Match. Activity needs to determine which of these descriptions apply.
Ogden Air Logistics Center, 5851 F Ave, Hill AFB, UT 84056-5713
TERMINAL ITEM (NON-STOCKED ITEMS) Future procurement is not authorized. No wholesale stock is available for issue. 1. Requisitions will not be processed to the wholesale manager. 2. Internal Service/agency requisitioning may be continued in accordance with the Service/agency requisitioning policies.
Unclassified
1
AIR FORCE ERRC XB3: Stock Fund (Except Munitions); DLA: This item has been reviewed and a determination made that the item cannot or should not be restored to a serviceable condition from an unserviceable condition; NAVY: 1I cog not stocked print on demand flat forms
Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.
TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.
Department of the Air Force
Source | PICA / SICA | Packaging Category | Storage | Preservation | Clean/Dry | INT Qty | Unit Weight | Unit Size | Unit Pack Cube | Item Weight | Item Dims |
---|---|---|---|---|---|---|---|---|---|---|---|
P | P | 33 | 1 | 000 | 2.4 lbs | 12.5in x 8.3in x 4in | 0.240 cu ft |
Preservation Material | Wrapping Material | Cushioning / Dunnage | Cushioning Thickness | Unit Container | Intermediate Container | Unit Container Level | Special Marking | Level A Packing | Level B Packing | Minimal Packing | Optional Procedure |
---|---|---|---|---|---|---|---|---|---|---|---|
00 | X | NS | 00 | B | 00 | M |
Primary Inventory Control Activity (PICA)
Primary Inventory Control Activity (PICA)
Greaseproof-waterproof bag, Sealed
Any suitable process that is not injurious to the item.
No requirement
As required to protect the item or elements of the package
PPP-B-1672, Type II, folding convoluted cushioning in reusable box.
No requirement.
Unit container provides level B packing protection.
No special marking
All packaging data is mandatory for compliance and no substitutions are permitted. Fast packs should be included in this category.
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
HUES | Color | BLACK 1ST POSITION PRIMARY INSULATION SECOND CONDUCTOR |
HUES | Color | WHITE 1ST POSITION PRIMARY INSULATION FIRST CONDUCTOR |
HUES | Color | GREEN 1ST POSITION PRIMARY INSULATION THIRD CONDUCTOR |
CXCW | Conductor Form | STRANDED ALL CONDUCTORS |
CXDQ | Conductor Arrangement And Quantity | 3 SINGLES |
ADVL | Cross Section Outside Diameter | 0.460 INCHES NOMINAL |
AAGR | Cross-Sectional Shape Style | ROUND |
AGAV | End Item Identification | TTU-373 TEST SET |
AMQN | Conductor Quantity | 3 |
MDCL | Material Document And Classification | QQ-W-343 FED SPEC SINGLE MATERIAL RESPONSE CORE CONDUCTOR ALL CONDUCTORS |
MATT | Material | COPPER CORE CONDUCTOR ALL CONDUCTORS |
CXGW | Individual Conductor Length | 2.000 INCHES NOMINAL 2ND END ALL CONDUCTORS |
CXDC | Round Conductor Size | 14 AWG ALL CONDUCTORS |
AAJU | Overall Length | 8.000 INCHES |
FEAT | Special Features | DWG TITLE CABLE ASSY ADAPTOR,115VAC, 400 HZ TO 50/60 HZ, W-6; CABLE,ELEC CAGE 81349, P/N CO-03(3/14)0460 |
ALBY | Usage Design | POWER |
CXFK | Voltage Rating | 600.0 MAXIMUM ROOT MEAN SQUARE (RMS) OPERATING VOLTAGE ALL CONDUCTORS |
CXDG | Strand Awg Size Per Conductor | 30 ALL CONDUCTORS |
BLNZ | Strand Quantity Per Conductor | 41 ALL CONDUCTORS |
STYL | Style Designator | INTERNAL CONNECTOR AND STRIPPED |
STDC | Surface Treatment Document And Classification | ASTM B33-63 ASSN STD 1ST TREATMENT RESPONSE CORE CONDUCTOR ALL CONDUCTORS |
SFTT | Surface Treatment | TIN CORE CONDUCTOR ALL CONDUCTORS |
ABJH | Temp Rating | -40.0 DEG CELSIUS AND 75.0 DEG CELSIUS |
CXGN | Terminal Commercial And Government Entity Code | 81348 1ST END ALL CONDUCTORS |
CXGG | Terminal Manufacturer Identifying Reference Number | WC-596/14-2 1ST END ALL CONDUCTORS |
AKRZ | Termination Type | CONNECTOR PLUG 1ST END ALL CONDUCTORS |
AKRZ | Termination Type | STRIPPED 2ND END ALL CONDUCTORS |